Atago 4496 Ramen Soup and Baume Refractometer, PAL-96S, Ramen Soup : 0.0 to 53.0% and Baume Kansui : 0.0 to 9.9° Measurement Range
This is the essential item in creasing your Ramen.This model can measure not noly the concentration of Soup and Tare but also baume of kansui used during making the noodle. If you are interested in Meister set of refractometer and salt meter, pleas choose Ramen Meister Set. For user testimonials of Japanese famous ramen restaurants, click here
Specifications
Specifications
Model PAL-96S Cat.No. 4496 Scale Ramen noodle soup
Baume KansuiRange Ramen noodle soup : 0.0 to 53.0%
Baume Kansui : 0.0 to 9.9°Resolution Chinese noodle soup : 0.1%
Baume Kansui : 0.1°
Temperature : 0.1゚CAccuracy Chinese noodle soup : ±0.2%
Baume Kansui : ±0.3°Temperature compensation 10 to 100゚C Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
WTW 2BA100 Oxi 3205 Dissolved Oxygen ProfiLine Portable Meter
WTW Oxi 3205 Easy-to-use, robust DO meter with backlit LCD graphic display, for routine measurement, single instrument - waterproof IP 67 - Menu controlled - backlit graphic display - measures saturation, concentration, partial pressure - Date and time function
Easy and waterproof, portable routine meter for the galvanized dissolved oxygen measurement in the field, for teaching and service
- Backlit graphic display
- Automatic barometric pressure compensation
- Waterproof (IP 67) and robust
Technical Data
* when using the DurOx® oxygen sensor Concentration 0.00 … 20.00 mg/l (0.0 ... 20.0 mg/l*) ±0.5 % of value.
0 … 90 mg/l ±0.5 % of valueSaturation 0.0 … 200.0 % (0 ... 200 %*) ±0.5 % of value
0 … 600 % ±0.5 % of valuePartial pressure 0.0 … 200.0 mbar (0 ... 200 mbar)* ±0.5 % of value
0 ... 1250 mbar ±0.5 % of valueTemperature -5.0 … +105.0 °C ±0.1 °C -
WTW 1BA300 inoLab® Oxi 7310 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA
Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food
- Application-relevant oxygen measurement by three selectable oxygen sensors
- Precise measurements based on automatic air pressure compensation
- Documentation of all data via USB interface or optional built-in printer - quick and error-free
Technical Data
alle values ±1 digit Concentration 0.00 … 20.00 mg/l ±0.5 % of value.
0 … 90 mg/L ±0.5 %Saturation 0.0 … 200.0 % ±0.5 % of value
0 to 600 % ±0.5 % of valuePartial pressure 0 … 200.0 hPa, 0 to 1250 hPa Temperature -5.0 … 105.0 °C ±0.1 °C Full Description
WTW inoLab® Oxi 7310 Professional dissolved oxygen meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors
-
Atago 4498 PAL-98S Digital Hand-Held "Pocket" Condiment Meter, Condiment Concentration : 0.0 to 70.0 %
Specifications
Model PAL-98S Cat.No. 4498 Scale Condiment Concentration
TemperatureMeasurement Range Condiment Concentration : 0.0 to 70.0 %
Temperature : 10.0 to 100゚CResolution Condiment Concentration : 0.1 %
Temperature : 0.1゚CMeasurement Accuracy Condiment Concentration : ±0.2 %
Temperature : ±1゚CTemperature compensation range 10 to 100゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g(Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
WTW 2BA101 Oxi 3205 Dissolved Oxygen Portable Meter Set including CellOx 325 Galvanic dissolved oxygen sensor 1.5 m cable
WTW 2BA101 Oxi 3205 Dissolved Oxygen Portable Meter Set including CellOx 325 Galvanic dissolved oxygen sensor 1.5 m cable
Easy-to-use, robust DO meter with backlit LCD graphic display, for routine measurement, Set including CellOx¨ 325 - waterproof IP 67 - Menu controlled - backlit graphic display - measures saturation, concentration, partial pressure
Easy and waterproof, portable routine meter for the galvanized dissolved oxygen measurement in the field, for teaching and service
- Backlit graphic display
- Automatic barometric pressure compensation
- Waterproof (IP 67) and robust
Technical Data
* when using the DurOx® oxygen sensor Concentration 0.00 … 20.00 mg/l (0.0 ... 20.0 mg/l*) ±0.5 % of value.
0 … 90 mg/l ±0.5 % of valueSaturation 0.0 … 200.0 % (0 ... 200 %*) ±0.5 % of value
0 … 600 % ±0.5 % of valuePartial pressure 0.0 … 200.0 mbar (0 ... 200 mbar)* ±0.5 % of value
0 ... 1250 mbar ±0.5 % of valueTemperature -5.0 … +105.0 °C ±0.1 °C -
Atago 4535 Pocket Tea Concentration Meter PAL-Tea, Brix : 0.00 to 25.00% Measurement Range, now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-Tea Cat.No. 4535 Scale Brix
TemperatureMeasurement Range Brix : 0.00 to 25.00%
Temperature : 10.0 to 100℃Resolution Brix : 0.01%
Temperature : 0.1℃Measurement Accuracy Brix : ±0.10%
Temperature : ±1℃Temperature compensation range 10 to 100℃ Ambient Temperature 10 to 40℃ Sample Volume At least 0.3mL Measurement Time Approx. 5 seconds
120 seconds of continuous measurementPower Supply Two (2) AAA alkaline batteries International Protection Class IP65 Dust-tight and Protected against water jets Dimensions & Weight 55 (W) x 31 (D) x 109 (H)mm,100g (main unit only) -
WTW 1BA300P inoLab® Oxi 7310P Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with built-in printer
Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food
- Application-relevant oxygen measurement by three selectable oxygen sensors
- Precise measurements based on automatic air pressure compensation
- Documentation of all data via USB interface or optional built-in printer - quick and error-free
Technical Data
alle values ±1 digit Concentration 0.00 … 20.00 mg/l ±0.5 % of value.
0 … 90 mg/L ±0.5 %Saturation 0.0 … 200.0 % ±0.5 % of value
0 to 600 % ±0.5 % of valuePartial pressure 0 … 200.0 hPa, 0 to 1250 hPa Temperature -5.0 … 105.0 °C ±0.1 °C Full Description
WTW inoLab® Oxi 7310 Professional dissolved oxygen meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors
-
WTW 1BA301 inoLab® Oxi 7310 SET 1 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with CellOx® 325 Galvanic oxygen sensor
Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food
- Application-relevant oxygen measurement by three selectable oxygen sensors
- Precise measurements based on automatic air pressure compensation
- Documentation of all data via USB interface or optional built-in printer - quick and error-free
Technical Data
alle values ±1 digit Concentration 0.00 … 20.00 mg/l ±0.5 % of value.
0 … 90 mg/L ±0.5 %Saturation 0.0 … 200.0 % ±0.5 % of value
0 to 600 % ±0.5 % of valuePartial pressure 0 … 200.0 hPa, 0 to 1250 hPa Temperature -5.0 … 105.0 °C ±0.1 °C Full Description
WTW inoLab® Oxi 7310 SET 1 Professional dissolved oxygen meter, menu controlled, for measurements/documentation according GLP/AQA. Set including galvanic D.O. sensor. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors
-
Atago 4571 Soil Moisture Meter PAL-Soil, Gravimetric soil moisture : 0 to 200%, Volumetric soil moisture : 0 to 100%, now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-Soil Cat.No. 4571 Scale Gravimetric soil moisture
Volumetric soil moisture
TemperatureMeasurement Range Gravimetric soil moisture : 0 to 200%
Volumetric soil moisture : 0 to 100%
Temperature : 10.0 to 40.0°CResolution Gravimetric soil moisture : 1%
Volumetric soil moisture : 1%
Temperature : 0.1°CMeasurement Accuracy Gravimetric soil moisture : ±2% (0 to 40%), ±5% (41 to 100%)
Volumetric soil moisture (Repeatability) : ±1% (0 to 60%),
±2%(61 to 100%)
Temperature : ±1.0°CTemperature compensation range 10 to 40゚C (Automatic Temperature Compensation) Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life About 11,000 measurements
(when an alkaline battery is used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
WTW 1BA304 inoLab® Oxi 7310 SET 4 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with StirrOx® Self-Stirring Dissolved Oxygen Sensor
Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food
- Application-relevant oxygen measurement by three selectable oxygen sensors
- Precise measurements based on automatic air pressure compensation
- Documentation of all data via USB interface or optional built-in printer - quick and error-free
Technical Data
alle values ±1 digit Concentration 0.00 … 20.00 mg/l ±0.5 % of value.
0 … 90 mg/L ±0.5 %Saturation 0.0 … 200.0 % ±0.5 % of value
0 to 600 % ±0.5 % of valuePartial pressure 0 … 200.0 hPa, 0 to 1250 hPa Temperature -5.0 … 105.0 °C ±0.1 °C Full Description
WTW inoLab® Oxi 7310 SET 4 inoLab¨ Oxi 7310 SET 4 Professional dissolved oxygen meter, menu controlled, for measurements/documentation according GLP/AQA. Set including galvanic D.O. sensor. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G
-
Atago 4573 Moisture Content Digital Refractometer, PAL-Moisture PAL Series, Moisture Content : 7.0 to 100% (g/100g) Measurement Range
Pocket >> Palm >> Perform IoT Supported With NFC Technology
This moisture meter provides quick estimation of water content, which is calculated by using the following formula : Moisture content = 100 – Brix
Brix represents the weight of sucrose in 100 grams of sucrose solution as a percentage by weight. When other dissolved solids are present in the solution, Brix conversion may be applied.
Brix is a measure of the total dissolved solids in a solution and indicates the combined concentration of all soluble substances, such as sugar, salt, protein, and acids.Specifications
Model PAL-Moisture Cat.No. 4573 Scale Moisture content
TemperatureMeasurement Range Moisture content : 7.0 to 100% (g/100g)
Temperature : 10.0 to 100℃Resolution Moisture content : 0.1%
Temperature : 0.1℃Measurement Accuracy Moisture content : ±0.2%
(When measuring a standard sucrose solution)
Temperature : ±1℃Temperature compensation range 10 to 100℃
(Automatic Temperature Compensation)Ambient Temperature 10 to 40℃ Sample Volume At least 0.3mL Measurement Time Approx. 3 seconds Power Supply Two (2) AAA alkaline batteries Battery Life Approx. 11,000 measurements
(when using alkaline batteries)International Protection Class P65 Dust-tight and Protected against water jets. Dimensions & Weight 55 (W) x 31 (D) x 109 (H)mm,100g (main unit only) Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4441 Calcium Chloride Digital Pocket Refractometer, PAL-41S PAL Series, Calcium Chloride : 0.0 to 35.0% Measurement Range
Pocket >> Palm >> Perform IoT Supported With NFC Technology
PAL-41S is suitable to measure the concentration of Calcium chloride water solution.This model is popular for checking the snow-melting agent.
Specifications
Model PAL-41S Cat.No. 4441 Scale Calcium chloride (g/100g)
TemperatureMeasurement Range Calcium chloride : 0.0 to 35.0%
Temperature : 10.0 to 40.0゚CResolution Calcium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Calcium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4574 PAL-Dried Fruit Moisture Digital Hand Held , "Pocket PAL Series" Dried Fruit Refractometer, Moisture : 7.0 to 100 % Measurement Range now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-Dried Fruit Moisture Cat.No. 4574 Scale Moisture
TemperatureMeasurement Range Moisture : 7.0 to 100 %
Temperature : 10.0 to 100゚CResolution Moisture : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Moisture : ±0.2 % (with honeydew)
Temperature : ±1゚CTemperature compensation range 10 to 100 ゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Included Accessories MAGIC™ Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4429 PAL-29S Digital Hand-Held "Pocket" Citric Acid Refractometer PAL Series, Citric Acid : 0.0 to 10.0% Measurement Range, now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-29S Cat.No. 4429 Scale Citric acid (g/100g)
TemperatureMeasurement Range Citric acid : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Citric acid : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Citric acid : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4492 PAL-92S Double Scale Coolant Refractometer for Ethylene Glycol/Freezing Point of Ethylene Glycol Digital Hand-Held "Pocket" Refractometer in Fahrenheit , now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-92S Cat.No. 4492 Scale Concentration of Ethylene Glycol
Freezing point of Ethylene Glycol (゚F)Measurement Range Concentration of Ethylene Glycol : 0.0 to 90.0% (V/V)* Main scale
Freezing point of Ethylene Glycol : 32 to -60゚F* Secondary scaleResolution Concentration of Ethylene Glycol : 0.2% (V/V)* Main scale
Freezing point of Ethylene Glycol : 1゚F* Secondary scaleMeasurement Accuracy Concentration of Ethylene Glycol : ±0.4% (V/V)* Main scale
Concentration of Ethylene Glycol : ±1゚F* Secondary scaleTemperature compensation range 50 to 104゚F (10 to 40゚C)
(Automatic Temperature Compensation)Ambient Temperature 50 to 104゚F(10 to 40゚C) Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) -
Atago 4489 PAL-89S Digital Hand-Held "Pocket" Propylene Glycol Refractometer PAL Series, 0.0 to 90.0% Measurement Range, now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-89S Cat.No. 4489 Scale Concentration of Propylene Glycol (V/V)
Freezing point of Propylene Glycol(゚F)Measurement Range Concentration of Propylene Glycol : 0.0 to 90.0% (V/V) * Main scale
Freezing point of Propylene Glycol : 32 to -60゚F * Secondary scaleResolution Concentration of Propylene Glycol : 0.2% (V/V)* Main scale
Freezing point of Propylene Glycol : 1゚F* Secondary scaleMeasurement Accuracy Concentration of Propylene Glycol : ±0.4% (V/V)* Main scale
Freezing point of Propylene Glycol : ±1゚F* Secondary scaleTemperature compensation range 50 to 104゚F (10 to 40゚C)
(Automatic Temperature Compensation)Ambient Temperature 50 to 104゚F (10 to 40゚C) Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4401 Digital Pocket Blood Serium Refractometer, PAL-11S PAL Series , Blood Serum Protein Scale: 0.0 to 12.0g/100mL Measurement Range
Pocket >> Palm >> Perform IoT Supported With NFC Technology
Blood Serum Protein Measurements with Only a Small Amount of Sample
The Digital Hand-held "Pocket" Blood Serum Protein Refractometer PAL-11S is simple to operate, allowing anyone to take precise and accurate blood serum protein measurements quickly and easily. It requires only a small amount of sample and measurement time is just 3 seconds. Its waterproof design allows the unit to be fully rinsed under running water, making clean-up after measurements a breeze.A small volume sample adaptor is included as a standard accessory.
Specifications
Model PAL-11S Cat.No. 4401 Measurement Range Serum protein scale : 0.0~12.0g/100mL
Temperature : 10.0 to 35.0℃Resolution Serum protein : 0.2g/100mL
Temperature : 0.1℃Measurement Accuracy Serum protein : ±0.2g/100mL
Temperature : ±1℃Temperature compensation range 10 to 35゚C (Automatic Temperature Compensation) Ambient Temperature 10 to 35゚C Sample Volume At least 3μl Measurement Time Approx. 3 seconds Power Supply 2 x AAA alkaline batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Included Accessories A very small amount of sample adapter standard attachment Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only) Patent for Design Registration No. ZL200310103015.2 (China)
Patent for Invention Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world.