High performance liquid chromatography is an essential method in the field of analytical separation.

In order to perform high quality analyses, new analytical methods and devices including detectors have been investigated through the efforts of many chromatographers. These efforts have resulted in the achievement of high performance analyses.

SHINWA CHEMICAL INDUSTRIES provides customers with columns with excellent separation performance and reproducibility anytime and anywhere. ULTRON columns are manufactured using stringent quality control throughout the production process.

 

Items: 140 of 50
Show: 40
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 100 × 2.1mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 100 × 3mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 100 × 4.6mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    ApplicationsSemimicro-LCSemimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.150 x 3.050 x 4.6
    100 x 2.1100 x 3.0100 x 4.6
    150 x 2.1150 x 3.0150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 150 × 2.1mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 150 × 3mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 150 × 4.6mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 50 × 2.1mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 50 × 3mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON ES-OVM-3 Chiral Separation Column, 50 × 4.6mm, 3um Particle Size

    Features

    1. Maximum operating pressure of 30 MPa.
    2. Can be used in LC/MS systems as well.
    3. Employs a 3 µm packing material for higher peak resolution and theoretical plate numbers.
    4. Enables significant reductions in analysis times while maintaining high theoretical plate numbers.
    5. Enables further improvements in performance with optimization of LC system tubing and flow cells.
    6. 9 column length and inner diameter combinations available.

    ULTRON ES-OVM-3 Lineup

    Applications Semimicro-LC Semimicro-LC
    Conventional-LC
    Conventional-LC
    Column Size
    Length x I.D. (mm)
    50 x 2.1 50 x 3.0 50 x 4.6
    100 x 2.1 100 x 3.0 100 x 4.6
    150 x 2.1 150 x 3.0 150 x 4.6
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Column, 150 × 4.0mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Column, 150 × 4.6mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Column, 150 × 6mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Column, 250 × 4.0mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Column, 250 × 4.6mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Guard Column, 10 × 4mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON STR ODS-M Reverse Phase HPLC Analytical Guard Column, 50 × 4mm, 5um Particle Size

     

    Column

    Particle Shape Particle Size Pore Size Specific Surface
    Area
    Carbon Content
    ODS-M Perfectly spherical porous silica gel 5μm 10 nm 350m2/g 15%

    Corresponds to USP number L01: Octadecyl silane bonded to porous silica or ceramic microparticles, 3 to 10 micrometers in diameter.

     

    Features

    1. The effects of metal oxides are suppressed to a minimum due to the use of highly-purified silica gel as a base material in the STR series.
    2. STR series columns are durable due to the use of mechanically strong silica gel.
    3. STR series columns are highly resistant to acidic and basic mobile phases.
    4. STR series columns are easy to operate and display high levels of performance due to low analytical operating pressures.
    5. Excellent end capping technology provides sharp peak shapes for basic and acidic compounds, and for samples which form complexes with metals.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-Octyl Reverse Phase HPLC Analytical Column, 150 × 4.6mm, 5um Particle Size

    Features

    1. Column lifetimes have been greatly improved.
    2. ULTRON VX-Octyl columns have very low variations between lots and display excellent reproducibility.
    3. ULTRON VX-Octyl columns provide shorter analysis times than ODS columns and can also maintain high separation capacities.
    4. Volumes of organic solvents can be reduced.
    5. Because distribution equilibriums can be achieved quickly and adsorbed materials can be eluted easily in comparison with ODS columns, these columns are perfect for gradient elutions.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-Octyl Reverse Phase HPLC Analytical Column, 250 × 4.6mm, 5um Particle Size

    Features

    1. Column lifetimes have been greatly improved.
    2. ULTRON VX-Octyl columns have very low variations between lots and display excellent reproducibility.
    3. ULTRON VX-Octyl columns provide shorter analysis times than ODS columns and can also maintain high separation capacities.
    4. Volumes of organic solvents can be reduced.
    5. Because distribution equilibriums can be achieved quickly and adsorbed materials can be eluted easily in comparison with ODS columns, these columns are perfect for gradient elutions.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-Octyl Reverse Phase HPLC Preparative Column, 250 × 20mm, 5um Particle Size

    Features

    1. Column lifetimes have been greatly improved.
    2. ULTRON VX-Octyl columns have very low variations between lots and display excellent reproducibility.
    3. ULTRON VX-Octyl columns provide shorter analysis times than ODS columns and can also maintain high separation capacities.
    4. Volumes of organic solvents can be reduced.
    5. Because distribution equilibriums can be achieved quickly and adsorbed materials can be eluted easily in comparison with ODS columns, these columns are perfect for gradient elutions.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-Octyl.G Reverse Phase HPLC Guard Column, 10 × 4.0mm, 5um Particle Size

    Features

    1. Column lifetimes have been greatly improved.
    2. ULTRON VX-Octyl columns have very low variations between lots and display excellent reproducibility.
    3. ULTRON VX-Octyl columns provide shorter analysis times than ODS columns and can also maintain high separation capacities.
    4. Volumes of organic solvents can be reduced.
    5. Because distribution equilibriums can be achieved quickly and adsorbed materials can be eluted easily in comparison with ODS columns, these columns are perfect for gradient elutions.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-Octyl.G Reverse Phase HPLC Guard Preparative Column, 15 × 8.0mm, 5um Particle Size

    Features

    1. Column lifetimes have been greatly improved.
    2. ULTRON VX-Octyl columns have very low variations between lots and display excellent reproducibility.
    3. ULTRON VX-Octyl columns provide shorter analysis times than ODS columns and can also maintain high separation capacities.
    4. Volumes of organic solvents can be reduced.
    5. Because distribution equilibriums can be achieved quickly and adsorbed materials can be eluted easily in comparison with ODS columns, these columns are perfect for gradient elutions.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 150 × 4.6mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 150 × 4.6mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 150 × 6.0mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 150 × 6.0mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 250 × 4.6mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 250 × 4.6mm, 15um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Analytical Column, 250 × 4.6mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Narrow Bore Column, 150 × 1.0mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Narrow Bore Column, 150 × 2.0mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Narrow Bore Column, 250 × 1.0mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Narrow Bore Column, 250 × 2.0mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 20.0mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 20mm, 15um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 20mm, 5um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 30.0mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 30mm, 15um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 50.0mm, 10um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
  • Shinwa Chemicals ULTRON VX-ODS Reverse Phase HPLC Preparative Column, 250 × 50mm, 15um Particle Size

    Specifications

    Particle Size Pore Size Specific Surface Area Carbon Content
    5μm 120A 300m2/g 16%

    Features

    Reproducibility between column lots

    1. Reproducibility between column lots
      ULTRON VX-ODS columns are checked using stringent quality control in each manufacturing process.
      Only ULTRON VX-ODS columns that pass repeated testing during the manufacturing processes are shipped to customers. k' and α values obtained using ULTRON VX-ODS columns display only extremely small differences between lots. ULTRON VX-ODS columns also display excellent reproducibility and stability in other tests between column lots.
    2. Stereoselectivity, distribution equilibria
      ULTRON VX-ODS columns, which have monolayers of octadecyl groups, display excellent stereoselectivity with respect to sample molecules. Distribution equilibria are reached rapidly when performing gradient elutions and when mobile phases are changed.
    3. Pressure resistance
      Because ULTRON VX-ODS columns use spherical silica gel, they display excellent pressure resistance, and stable separations can be achieved even at fast mobile phase flow rates.
    Price Upon Application Or Discontinued
Items: 140 of 50
Show: 40