Julabo 9013000 CORIO CP Immersion Circulator, +20 ... +200 °C Working Temperature Range
Specifications
Dimensions and volumes Dimensions
(W × L × H)13.2 x 16 x 36.2 cm Usable immersion depth 16 cm Weight 2.5 kg Temperature values Working temperature range +20 ... +200 °C Temperature stability ±0.02 °C Temperature display resolution 0.01 ... 0.1 °C Ambient temperature +5 ... +40 °C Performance values Heating capacity 2 kW Pump capacity flow rate 8 ... 27 l/min Pump capacity flow pressure 0.1 ... 0.7 bar Viscosity max. 50 cST Cooling Cooling coil accessory Other Classification
according to DIN12876-1Classification III (FL) IP Code
according to IEC 60529IP 21 Pump function Pressure Pump Pump type Immersion Pump Electronics Temperature control PID1 Absolute temperature calibration 1 Point Calibration Temperature display LED Temperature setting Keypad Electronic Timer
hr:min0 ... 999 -
Julabo 9011000 CORIO C Heating Immersion Circulator, +20 ... +100 °C , 6 Circulation Capacity Flow Rate (l/min)
Specifications
Dimensions and volumes Dimensions
(W × L × H)13.2 x 16 x 36.2 cm Usable immersion depth 16.6 cm Weight 1.9 kg Temperature values Working temperature range +20 ... +100 °C Temperature stability ±0.03 °C Setting the resolution of the temperature display 0.1 °C Temperature display resolution 0.01 ... 0.1 °C Ambient temperature +5 ... +40 °C Performance values Heating capacity 2 kW Viscosity max. 1 cST Circulation capacity flow rate 6 l/min Cooling Cooling coil accessory Other Classification
according to DIN12876-1Classification I (NFL) IP Code
according to IEC 60529IP 21 Pump type Immersion Pump Electronics Temperature control PID1 Absolute temperature calibration 1 Point Calibration Temperature display LED Temperature setting Keypad -
Julabo 9021000 DYNEO DD Heating Immersion Circulator, +20 ... +200°C Working Temperature Range
Specifications
Dimensions and volumes Dimensions
(W × L × H)13.2 x 16 x 35.5 cm Usable immersion depth 16 cm Weight 2.5 kg Temperature values Working temperature range +20 ... +200 °C Temperature stability ±0.01 °C Setting the resolution of the temperature display 0.01 °C Ambient temperature +5 ... +40 °C Performance values Heating capacity 2 kW Pump capacity flow rate 8 ... 27 l/min Pump capacity flow pressure 0.1 ... 0.7 bar Viscosity max. 50 cST Cooling Cooling coil accessory Other Classification
according to DIN12876-1Classification III (FL) IP Code
according to IEC 60529IP 21 Pump function Pressure Pump Pump type Immersion Pump Electronics External pt100 sensor connection integrated Integrated programmer 8x60 steps Temperature control PID2 Absolute temperature calibration 3 Point Calibration Temperature display 3.5" TFT Display Temperature setting Shaft Encoder Electronic Timer
hr:min99 ... 59 -
Julabo 9021000.A DYNEO DD Heating Immersion Circulator, +20 ... +200°C Working Temperature Range, with Analog Option
Technical Data
Order No. 9021000 Order No. with RS232 Option 9021000.D Order No. with analog Option 9021000.A Model series DYNEO Category Heating Immersion Circulators Working temperature range (°C) +20 ... +200 Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Ambient temperature 5...40 °C Dimensions W x L x H (cm) 13.2 x 16 x 35.5 Weight (kg) 2.5 Cooling coil optional Usable immersion depth (cm) 16 Connection. Easy.
Inclined pump connections (M16x1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.Technical changes without prior notification.
Images may deviate from the original. -
Julabo 9021000.D DYNEO DD Heating Immersion Circulator, +20 ... +200°C Working Temperature Range, with RS232 Option
Technical Data
Order No. 9021000 Order No. with RS232 Option 9021000.D Order No. with analog Option 9021000.A Model series DYNEO Category Heating Immersion Circulators Working temperature range (°C) +20 ... +200 Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Ambient temperature 5...40 °C Dimensions W x L x H (cm) 13.2 x 16 x 35.5 Weight (kg) 2.5 Cooling coil optional Usable immersion depth (cm) 16 Connection. Easy.
Inclined pump connections (M16x1) facilitate the connection of applications. Each unit includes 2 barbed fittings of 8/12 mm diameter each.Technical changes without prior notification.
Images may deviate from the original. -
Julabo 9252218 SE-Z Bridge Mounted Circulators, +20 ... +300 °C, 22-26 Pump capacity flow rate (l/min)
Technical Data
Order No. 9252218 Model series HighTech Category Bridge Mounted Circulators Working temperature range (°C) +20 ... +300 Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 3 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 32 x 17 x 40 Weight (kg) 8 Classification according to DIN12876-1 Classification III (FL) Description A cooling coil is integrated for working below or near the ambient temperature. Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling coil integrated Usable immersion depth (cm) 12 - 19 -
Julabo 9153634 F34-MA Refrigerated/Heating Circulator, -30 ... +150°C Working Temperature Range, 20 Litre Capacity
Technical Data
Order No. 9153634 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +150 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.32 0.14 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 24 x 30 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 20 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 38 x 58 x 62 Weight (kg) 42 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162634 F34-ME Refrigerated/Heating Circulator, -30 ... +150°C Working Temperature Range, 20 Litre Capacity
Technical Data
Order No. 9162634 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +150 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.32 0.14 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 24 x 30 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 20 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 38 x 58 x 62 Weight (kg) 42 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air -
Julabo 9153632 F32-MA Refrigerated/Heating Circulator, -35 ... +200°C Working Temperature Range, 8 Litre Capacity
Technical Data
Order No. 9153632 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.39 0.15 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant stage 1 R134a Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 64 Weight (kg) 37 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available -
Julabo 9352755 FP55-SL Ultra-Low Refrigerated-Heating Circulator, -60 ... +100°C, 22-26 Pump capacity flow rate (l/min)
Technical Data
Order No. 9352755 Model series HighTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -60 ... +100 Temperature stability (°C) ±0.05 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60 kW 5.2 4.1 2.2 0.7 0.13 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 27 Refrigerant R404A External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 85 x 76 x 116 Weight (kg) 192 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air -
Julabo 9153633 F33-MA Refrigerated/Heating Circulator, -30 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9153633 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.5 0.32 0.12 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 145 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.207 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 69 Weight (kg) 44 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162633 F33-ME Refrigerated/Heating Circulator, -30 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9162633 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.5 0.32 0.12 0.05 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 145 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.207 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 69 Weight (kg) 44 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9153640 FP40-MA Refrigerated/Heating Circulator, -40 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9153640 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -40 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.68 0.5 0.32 0.04 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 263 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.031 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 37 x 46 x 69 Weight (kg) 48 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/13 Additional voltage versions available -
Julabo 9153625 F25-MA Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9153625 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 61 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162625 F25-ME Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9162625 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 61 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available -
Julabo 9162626 F26-ME Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9162626 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 42 x 42 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9153618 FP35-MA Refrigerated/Heating Circulator, -35 ... +150°C Working Temperature Range, 2.5 Litre Capacity
Technical Data
Order No. 9153618 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +150 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.34 0.15 0.05 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / -- Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 2.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 190 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.272 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 64 Weight (kg) 37 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9021702 DYNEO DD-201F Refrigerated/Heating Circulator, Working Temperature Range -20 ... +200 °C, 3 ... 4 Filling Volume Litres
Technical Data
Order No. 9021702 Order No. with RS232 Option 9021702.D Order No. with analog Option 9021702.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -20 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 200 20 10 0 -10 -20 kW 0.2 0.2 0.17 0.15 0.1 0.02 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Bath opening / bath depth (W x L / D cm) 13 x 15 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 3 ... 4 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 70 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.1 Ambient temperature 5...40 °C Dimensions W x L x H (cm) 44 x 41 x 44 Weight (kg) 24.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air