AND Instruments AD-8127 Statistical Impact Dot Matrix Printer
Robust DOT matrix printer with comprehensive statistical functions including: weight, total weight, count data, total, number of operations, maximum, minimum, bandwidth and standard deviation. Simple operation and programming.
-
Atago 4492 PAL-92S Double Scale Coolant Refractometer for Ethylene Glycol/Freezing Point of Ethylene Glycol Digital Hand-Held "Pocket" Refractometer in Fahrenheit , now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-92S Cat.No. 4492 Scale Concentration of Ethylene Glycol
Freezing point of Ethylene Glycol (゚F)Measurement Range Concentration of Ethylene Glycol : 0.0 to 90.0% (V/V)* Main scale
Freezing point of Ethylene Glycol : 32 to -60゚F* Secondary scaleResolution Concentration of Ethylene Glycol : 0.2% (V/V)* Main scale
Freezing point of Ethylene Glycol : 1゚F* Secondary scaleMeasurement Accuracy Concentration of Ethylene Glycol : ±0.4% (V/V)* Main scale
Concentration of Ethylene Glycol : ±1゚F* Secondary scaleTemperature compensation range 50 to 104゚F (10 to 40゚C)
(Automatic Temperature Compensation)Ambient Temperature 50 to 104゚F(10 to 40゚C) Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) -
Atago 4401 Digital Pocket Blood Serium Refractometer, PAL-11S PAL Series , Blood Serum Protein Scale: 0.0 to 12.0g/100mL Measurement Range
Pocket >> Palm >> Perform IoT Supported With NFC Technology
Blood Serum Protein Measurements with Only a Small Amount of Sample
The Digital Hand-held "Pocket" Blood Serum Protein Refractometer PAL-11S is simple to operate, allowing anyone to take precise and accurate blood serum protein measurements quickly and easily. It requires only a small amount of sample and measurement time is just 3 seconds. Its waterproof design allows the unit to be fully rinsed under running water, making clean-up after measurements a breeze.A small volume sample adaptor is included as a standard accessory.
Specifications
Model PAL-11S Cat.No. 4401 Measurement Range Serum protein scale : 0.0~12.0g/100mL
Temperature : 10.0 to 35.0℃Resolution Serum protein : 0.2g/100mL
Temperature : 0.1℃Measurement Accuracy Serum protein : ±0.2g/100mL
Temperature : ±1℃Temperature compensation range 10 to 35゚C (Automatic Temperature Compensation) Ambient Temperature 10 to 35゚C Sample Volume At least 3μl Measurement Time Approx. 3 seconds Power Supply 2 x AAA alkaline batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Included Accessories A very small amount of sample adapter standard attachment Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only) Patent for Design Registration No. ZL200310103015.2 (China)
Patent for Invention Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4407 PAL-07S Digital Hand-Held "Pocket" Sea water (S.G.) Refractometer, Sea water (S.G.) : 1.000 to 1.070
Specifications
Model PAL-07S Cat.No. 4407 Scale Sea water (S.G.)
TemperatureMeasurement Range Sea water (S.G.) : 1.000 to 1.070
Temperature : 10.0 to 40.0゚CResolution Sea water (S.G.) : 0.001
Temperature : 0.1゚CMeasurement Accuracy Sea water (S.G.) : ±0.002
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4506 PAL-106S Digital Hand-Held "Pocket" Refractometer PAL Series, Sodium Chloride : 0.0 to 33.0%(g/100mL)
Specifications
Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4443 PAL-43S Digital Hand-Held "Pocket" Magnesium Chloride Refractometer, Magnesium Chloride : 0.0 to 30.0%
Specifications
Model PAL-43S Cat.No. 4443 Scale Magnesium chloride
TemperatureMeasurement Range Magnesium chloride : 0.0 to 30.0%
Temperature : 10.0 to 40.0゚CResolution Magnesium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Magnesium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4432 PAL-32S Digital Hand-Held "Pocket" Phosphoric Acid Refractometer, Phosphoric acid : 0.0 to 20.0%
Specifications
Model PAL-32S Cat.No. 4432 Scale Phosphoric acid (g/100g)
TemperatureMeasurement Range Phosphoric acid : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Phosphoric acid : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Phosphoric acid : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4464 PAL-64S Digital Hand-Held "Pocket" Sodium bicarbonate Refractometer, Sodium bicarbonate : 0.0 to 10.0%
Specifications
Model PAL-64S Cat.No. 4464 Scale Sodium bicarbonate (g/100g)
TemperatureMeasurement Range Sodium bicarbonate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Sodium bicarbonate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium bicarbonate : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4465 PAL-65S Digital Hand-Held "Pocket" Sodium tartrate Refractometer, Sodium tartrate :0.0 to 25.0%
Specifications
Model PAL-65S Cat.No. 4465 Scale Sodium tartrate (g/100g)
TemperatureMeasurement Range Sodium tartrate :0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Sodium tartrate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium tartrate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4470 PAL-70S Digital Hand-Held "Pocket" Potassium Phosphate Refractometer, 0.0 to 15.0% Range
Specifications
Model PAL-70S Cat.No. 4470 Scale Potassium phosphate
TemperatureMeasurement Range Potassium phosphate :0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Potassium phosphate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium phosphate : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4405 PAL-05S Digital Hand-Held "Pocket" Sodium Chloride (Baume) Refractometer, Sodium chloride (Baume) : 0.0 to 25.7°
Specifications
Model PAL-05S Cat.No. 4405 Scale Sodium chloride (Baume)
TemperatureMeasurement Range Sodium chloride (Baume) : 0.0 to 25.7°
Temperature : 10.0 to 40.0°CResolution Sodium chloride (Baume) : 0.1°
Temperature : 0.1°CMeasurement Accuracy Sodium chloride (Baume) : ±0.2°
Temperature : ±1°CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40°C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4413 PAL-13S Digital Hand-Held "Pocket" Creatine Refractometer, Creatine : 0.0 to 10.0%
Specifications
Model PAL-13S Cat.No. 4413 Scale Creatine (g/100g)
TemperatureMeasurement Range Creatine : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Creatine : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Creatine : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4466 PAL-66S Digital Hand-Held "Pocket" Potassium Oxalate Refractometer, 0.0 to 10.0% Range
Specifications
Model PAL-66S Cat.No. 4466 Scale Potassium oxalate (g/100g)
TemperatureMeasurement Range Potassium oxalate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Potassium oxalate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium oxalate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4468 PAL-68S Digital Hand-Held "Pocket" Potassium Dichromate Refractometer, 0.0 to 15.0% Range
Specifications
Model PAL-68S Cat.No. 4468 Scale Potassium dichromate (g/100g)
TemperatureMeasurement Range Potassium dichromate : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Potassium dichromate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium dichromate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world -
Atago 4472 PAL-72S Digital Hand-Held "Pocket" Sodium Tungstate Refractometer, 0.0 to 10.0% Range
Specifications
Model PAL-72S Cat.No. 4472 Scale Sodium tungstate (g/100g)
TemperatureMeasurement Range Sodium tungstate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Sodium tungstate : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Sodium tungstate : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4438 PAL-38S Digital Hand-Held "Pocket" Dimethylformamide Refractometer, 0.0 to 45.0% Range
Specifications
Model PAL-38S Cat.No. 4438 Scale Dimethyl formamide
TemperatureMeasurement Range Dimethyl formamide : 0.0 to 45.0%
Temperature : 10.0 to 40.0゚CResolution Dimethyl formamide : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Dimethyl formamide : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4421 PAL-21S Digital Hand-Held "Pocket" Dextrin Refractometer, 0.0 to 30.0% Range
Specifications
Model PAL-21S Cat.No. 4421 Scale Dextrin (g/100g)
TemperatureMeasurement Range Dextrin : 0.0 to 30.0% (g/100g)
Temperature : 10.0 to 40.0゚CResolution Dextrin : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Dextrin : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4455 PAL-55S Digital Hand-Held "Pocket" Magnesium Sulfate Refractometer PAL Series, 0.0 to 25.0% Range
Specifications
Model PAL-55S Cat.No. 4455 Scale Magnesium sulfate (g/100g)
TemperatureMeasurement Range Magnesium sulfate : 0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Magnesium sulfate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Magnesium sulfate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world.