Mettler Toledo 51338014 Bromonaphthalene density/refractive index combined standard (9 ml) - Certified Standard
Two Parameters in One
The combined density and refractive index standards verify both measuring cells of a combined instrument in one simple step.
No Manual Handling
The standard reference material comes in vials suitable for direct use on our SC1 and SC30 automation units – no syringe needed.
Barcode Certificates
All certificate information is coded in a single barcode. Users can simply scan the barcode and the system will do everything else.
-
Buchi 051999 Melting Point M-560, Ambient + 10 °C to 400 °C, 3 Positions for melting capillaries
The Melting Point M-560 is designed for manual determination of melting and boiling points. The easy observation of the phase transition through a magnifying lens together with the intuitive calibration and verification procedures ensure highly accurate measurements.
Technical data
- Positions for melting capillaries 3
- Positions for boiling capillaries 1
- Precision magnifying lens 1
- Magnification of lens 2.5 x
- Display Color, TFT, 320 x 240, 3.5˝
- Determination temperature range Ambient + 10 °C to 400 °C 3
- Temperature resolution 0.1 °C
- Accuracy of the oven temperature at 0.5 °C/min up to 250 °C ± 0.3 °C 250 °C to 400 °C ± 0.3 °C to ± 0.5 °C
- Repeatability of melting point at 0.5 °C/min ± 0.1 °C
- Accuracy of boiling point at 1.0 °C/min up to 400 °C ± 0.5 °C
- Temperature gradients, °C/min 0.1, 0.2, 0.5, 1, 1.5, 2, 2.5, 3, 5, 10, 20
- Heat-up time (50 °C – 350 °C) at 25 °C ~ 4 min
- Cool-down time (350 °C – 50 °C) at 25 °C ~ 13 min
- Electrical supply 100 – 240 V (±10 %) 50 – 60 Hz
- Power consumption 150 W
- Storable methods for melting point 50
- Storable methods for boiling point 50
- Compliant with Pharmacopeia methods PH. EUR., USP and JP
- Interfaces 1 x PS/2 1 x RS232 1 x USB
- Languages en / de / fr / it / es / ja / cn
-
Hanna HI-839800 25 Vial Thermo-Reactor
The Hanna HI-839800 thermo-reactor is an easy to use test tube heater with the capacity to perform up to 25 simultaneous digestions. Complete with a countdown timer, it can be used for timed or infinity testing procedures.
Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.
-
Hanna Instruments HI-93703-11 Portable ISO Compliant Turbidity Meter with Data Logging and PC Connectivity
The HI-93703-11 is a high accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI-93703-11 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements. Additionally, this meter contains a real-time clock and the capabilities to log measurements and transfer them to a PC using the HI-92000 software.
- Auto shut-off
- Positive-locking cuvette system ensures cuvette is firmly placed in the cell
- Logging and real time clock
Specifications
Turbidity Range 0.00 to 50.00;
50 to 1000Resolution 0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)Accuracy ±0.5 FTU or ±5% of reading (whichever is greater) Calibration 3 points (0 FTU, 10 FTU and 500 FTU) Light Source infrared LED Light Life Life of the instrument Light Detection Silicon Photocell Battery Type / Life 4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
automatic shut-off after 5 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") Weight 510 g (1.1 lb.) -
Hanna Instruments HI-93414-02 EPA Compliant Turbidity and Free & Total Chlorine Meter
The HI-93414 is a multiparameter instrument that measures the most important parameters in drinking water: turbidity and chlorine. The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences.
The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine
Specifications
Turbidity Range 0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 1000 NTUFree and Total Chlorine Range 0.00 to 5.00 mg/L Range Selection Automatic Turbidity Resolution 0.01 NTU from 0.00 to 9.99 NTU
0.1 NTU from 10.0 to 99.9 NTU
1 NTU from 100 to 1000 NTUFree and Total Chlorine Resolution 0.01 mg/L from 0.00 to 3.50mg/L
0.10 above 3.50 mg/LTurbidity Accuracy ±2% of reading plus 0.02 NTU Free and Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Repeatability ±1% of reading or 0.02 NTU, whichever is greater Stray Light < 0.02 NTU Light Source tungsten filament lamp Light Detector Silicon Photocell Turbidity Method Ratio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B Free and Total Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample Turbidity Standards < 0.1, 15, 100 and 750 FTU Free and Total Chlorine Standards 1 mg/L free chlorine, 1 mg/L total chlorine Turbidity Calibration Two, three or four point calibration Free and Total Chlorine Calibration one-point calibration Logging Memory 200 records Serial Interface RS232 and USB Environment up to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 4 x 1.5V AA alkaline batteries or AC adapter Auto Shut-off After 15 minutes of non-use Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0") Weight 512 g (18 oz.)