More search options
21 products found
  • Atago PAL Series Brix Digital Pocket Refractometers
    • 20% off
    • £240.00
  • Atago 4413 PAL-13S Digital Hand-Held "Pocket" Creatine Refractometer, Creatine : 0.0 to 10.0%

    Specifications
    ModelPAL-13S
    Cat.No.4413
    ScaleCreatine (g/100g)
    Temperature
    Measurement RangeCreatine : 0.0 to 10.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionCreatine : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyCreatine : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement
    (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)
     
    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410

     

    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4401 Digital Pocket Blood Serium Refractometer, PAL-11S PAL Series , Blood Serum Protein Scale: 0.0 to 12.0g/100mL Measurement Range

     

    Pocket >> Palm >> Perform IoT Supported With NFC Technology

    Blood Serum Protein Measurements with Only a Small Amount of Sample

    The Digital Hand-held "Pocket" Blood Serum Protein Refractometer PAL-11S is simple to operate, allowing anyone to take precise and accurate blood serum protein measurements quickly and easily. It requires only a small amount of sample and measurement time is just 3 seconds. Its waterproof design allows the unit to be fully rinsed under running water, making clean-up after measurements a breeze.A small volume sample adaptor is included as a standard accessory.

    Specifications
    ModelPAL-11S
    Cat.No.4401
    Measurement RangeSerum protein scale : 0.0~12.0g/100mL
    Temperature : 10.0 to 35.0℃
    ResolutionSerum protein : 0.2g/100mL 
    Temperature : 0.1℃
    Measurement AccuracySerum protein : ±0.2g/100mL
    Temperature : ±1℃
    Temperature compensation range10 to 35゚C (Automatic Temperature Compensation)
    Ambient Temperature10 to 35゚C
    Sample VolumeAt least 3μl
    Measurement TimeApprox. 3 seconds
    Power Supply2 x AAA alkaline batteries
    Battery LifeApprox. 11,000 times measurement
    (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Included AccessoriesA very small amount of sample adapter standard attachment
    Dimensions & Weight55(W)×31(D)×109(H)mm, 100g (Main Unit only)
     

    Patent for Design Registration No. ZL200310103015.2 (China)
    Patent for Invention Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4506 PAL-106S Digital Hand-Held "Pocket" Refractometer PAL Series, Sodium Chloride : 0.0 to 33.0%(g/100mL)

    Specifications

    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410

    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.


    Price Upon Application Or Discontinued
  • Binder 6010-0574 Pallett 115 Apt 2

    • Under our terms and condition of sales any service or spares parts have a non cancellation and non refundable policy.
    • We also require the model number and serial number for the instrument to process any order
    Price Upon Application Or Discontinued
  • Binder 6010-0172 Pallet 150 Cb / E2 Nh

    • Under our terms and condition of sales any service or spares parts have a non cancellation and non refundable policy.
    • We also require the model number and serial number for the instrument to process any order
    Price Upon Application Or Discontinued
  • Binder 6010-0176 Pallet 115 Vd/L Non Wood

    • Under our terms and condition of sales any service or spares parts have a non cancellation and non refundable policy.
    • We also require the model number and serial number for the instrument to process any order
    Price Upon Application Or Discontinued
  • Binder 6010-0184 Pallet 115 Kb/E2 Nh

    • Under our terms and condition of sales any service or spares parts have a non cancellation and non refundable policy.
    • We also require the model number and serial number for the instrument to process any order
    Price Upon Application Or Discontinued
  • Binder 6010-0566 Pallet 1020 Kbf/E5.3

    • Under our terms and condition of sales any service or spares parts have a non cancellation and non refundable policy.
    • We also require the model number and serial number for the instrument to process any order
    Price Upon Application Or Discontinued
  • Atago 4446 PAL-46S Digital Hand-Held "Pocket" Cobalt Chloride Refractometer PAL Series, 0.0 to 15.0% Range

    Specifications
    ModelPAL-46S
    Cat.No.4446
    ScaleCobalt chloride (g/100g)
    Temperature
    Measurement RangeCobalt chloride : 0.0 to 15.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionCobalt chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyCobalt chloride : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement 
    (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4447 PAL-47S Digital Hand-Held "Pocket" Ferric Chloride Refractometer PAL Series, 0.0 to 15.0% Range

    Specifications
    ModelPAL-47S
    Cat.No.4447
    ScaleFerric chloride (g/100g)
    Temperature
    Measurement RangeFerric chloride : 0.0 to 15.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionFerric chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyFerric chloride : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4444 PAL-44S Digital Hand-Held "Pocket" Lithium Chloride Refractometer PAL Series, 0.0 to 20.0% Range

    Specifications
    ModelPAL-44S
    Cat.No.4444
    ScaleLithium chloride (g/100g)
    Temperature
    Measurement RangeLithium chloride : 0.0 to 20.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionLithium chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyLithium chloride : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4445 PAL-45S Digital Hand-Held "Pocket" Barium Chloride Refractometer PAL Series, 0.0 to 25.0% Range

    Specifications
    ModelPAL-45S
    Cat.No.4445
    ScaleBarium chloride (g/100g)
    Temperature
    Measurement RangeBarium chloride : 0.0 to 25.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionBarium chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyBarium chloride : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4448 PAL-48S Digital Hand-Held "Pocket" Strontium Chloride Refractometer PAL Series, 0.0 to 25.0% Range

    Specifications
    ModelPAL-48S
    Cat.No.4448
    ScaleStrontium chloride (g/100g)
    Temperature
    Measurement RangeStrontium chloride : 0.0 to 25.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionStrontium chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyStrontium chloride : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4449 PAL-49S Digital Hand-Held "Pocket" Potassium Chloride Refractometer PAL Series, 0.0 to 30.0% Range

    Specifications
    ModelPAL-49S
    Cat.No.4449
    ScalePotassium chloride (g/100g)
    Temperature
    Measurement RangePotassium chloride : 0.0 to 30.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionPotassium chloride : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyPotassium chloride : ±0.2% 
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40°C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued
  • Atago 4450 PAL-50S Digital Hand-Held "Pocket" Potassium Bromide Refractometer PAL Series, 0.0 to 35.0% Range

    Specifications
    ModelPAL-50S
    Cat.No.4450
    ScalePotassium bromide (g/100g)
    Temperature
    Measurement RangePotassium bromide : 0.0 to 35.0%
    Temperature : 10.0 to 40.0゚C
    ResolutionPotassium bromide : 0.1%
    Temperature : 0.1゚C
    Measurement AccuracyPotassium bromide : ±0.2%
    Temperature : ±1゚C
    Temperature compensation range10 to 40゚C 
    (Automatic Temperature Compensation)
    Ambient Temperature10 to 40゚C
    Sample Volume0.3 mL
    Measurement Time3 seconds
    Power Supply2 x AAA Batteries
    Battery LifeApprox. 11,000 times measurement (when alkaline batteries are used)
    International Protection ClassIP65 Dust-tight and Protected against water jets.
    Dimensions & Weight55(W) x 31(D) x 109(H)mm, 100g (Main Unit only)


    Options

    · PAL-CASE : RE-39409

    · PAL Silicone Cover : RE-39413

    · STRAP : RE-39410


    Patent for Invention Registration No. ZL200310103015.2 (China)
    Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
    Patent Granted in countries around the world.

    Price Upon Application Or Discontinued