Atago 4506 PAL-106S Digital Hand-Held "Pocket" Refractometer PAL Series, Sodium Chloride : 0.0 to 33.0%(g/100mL)
Specifications
Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4413 PAL-13S Digital Hand-Held "Pocket" Creatine Refractometer, Creatine : 0.0 to 10.0%
Specifications
Model PAL-13S Cat.No. 4413 Scale Creatine (g/100g)
TemperatureMeasurement Range Creatine : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Creatine : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Creatine : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4426 PAL-26S Digital Hand-Held Pocket Mannitol Refractometer, 0.0 to 15.0% Range
Specifications
Model PAL-26S Cat.No. 4426 Scale Mannitol (g/100g)
TemperatureMeasurement Range Mannitol : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Mannitol : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Mannitol : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4438 PAL-38S Digital Hand-Held "Pocket" Dimethylformamide Refractometer, 0.0 to 45.0% Range
Specifications
Model PAL-38S Cat.No. 4438 Scale Dimethyl formamide
TemperatureMeasurement Range Dimethyl formamide : 0.0 to 45.0%
Temperature : 10.0 to 40.0゚CResolution Dimethyl formamide : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Dimethyl formamide : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4421 PAL-21S Digital Hand-Held "Pocket" Dextrin Refractometer, 0.0 to 30.0% Range
Specifications
Model PAL-21S Cat.No. 4421 Scale Dextrin (g/100g)
TemperatureMeasurement Range Dextrin : 0.0 to 30.0% (g/100g)
Temperature : 10.0 to 40.0゚CResolution Dextrin : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Dextrin : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4486 PAL-86S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, Oe (GER) : 0 to 240° Range
Specifications
Model PAL-86S Cat.No. 4486 Scale Oe (GER)
Brix
TemperatureMeasurement Range Oe (GER) : 0 to 240°
Brix : 0.0 to 53.0%
Temperature : 10.0 to 40.0°CResolution Oe (GER) : 1°
Brix : 0.1%
Temperature : 0.1°CMeasurement Accuracy Oe (GER) : ± 1°
Brix : ± 0.2%
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· STRAP : RE-39410
* Calibration Certificate : Contact an ATAGO representative for details.
-
Atago 4492 PAL-92S Double Scale Coolant Refractometer for Ethylene Glycol/Freezing Point of Ethylene Glycol Digital Hand-Held "Pocket" Refractometer in Fahrenheit , now with Near Field Communication
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
Specifications
Model PAL-92S Cat.No. 4492 Scale Concentration of Ethylene Glycol
Freezing point of Ethylene Glycol (゚F)Measurement Range Concentration of Ethylene Glycol : 0.0 to 90.0% (V/V)* Main scale
Freezing point of Ethylene Glycol : 32 to -60゚F* Secondary scaleResolution Concentration of Ethylene Glycol : 0.2% (V/V)* Main scale
Freezing point of Ethylene Glycol : 1゚F* Secondary scaleMeasurement Accuracy Concentration of Ethylene Glycol : ±0.4% (V/V)* Main scale
Concentration of Ethylene Glycol : ±1゚F* Secondary scaleTemperature compensation range 50 to 104゚F (10 to 40゚C)
(Automatic Temperature Compensation)Ambient Temperature 50 to 104゚F(10 to 40゚C) Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) -
Atago 4484 PAL-84S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, Baume : 0.0 to 21.0° Range
Specifications
Model PAL-84S Cat.No. 4484 Scale Baume
TemperatureMeasurement Range Baume : 0.0 to 21.0°
Temperature : 10.0 to 40.0°CResolution Baume : 0.1°
Temperature : 0.1°CMeasurement Accuracy Baume : ± 0.2°
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
-
Atago 4479 PAL-79S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, T.A.1990 : 0.0 to 26.0% Range
Specifications
Model PAL-79S Cat.No. 4479 Scale T.A.1990
TemperatureMeasurement Range T.A.1990 : 0.0 to 26.0%
Temperature : 10.0 to 40.0°CResolution T.A.1990 : 0.1%
Temperature : 0.1°CMeasurement Accuracy T.A.1990 : ± 0.2%
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· STRAP : RE-39410
* Calibration Certificate : Contact an ATAGO representative for details.
-
Atago 4480 PAL-80S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, T.A.1971 : 0.0 to 25.0% Range
Specifications
Model PAL-80S Cat.No. 4480 Scale T.A.1971
TemperatureMeasurement Range T.A.1971 : 0.0 to 25.0%
Temperature : 10.0 to 40.0°CResolution T.A.1971 : 0.1%
Temperature : 0.1°CMeasurement Accuracy T.A.1971 : ± 0.2%
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· STRAP : RE-39410
* Calibration Certificate : Contact an ATAGO representative for details.
-
Atago 4483 PAL-83S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, KMW (or Babo) : 0.0 to 40.0° Range
Specifications
Model PAL-83S Cat.No. 4483 Scale KMW (or Babo)
TemperatureMeasurement Range KMW (or Babo) : 0.0 to 40.0°
Temperature : 10.0 to 40.0°CResolution KMW (or Babo) : 0.1°
Temperature : 0.1°CMeasurement Accuracy KMW (or Babo) : ±0.2°
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· STRAP : RE-39410
* Calibration Certificate : Contact an ATAGO representative for details.
-
Atago 4470 PAL-70S Digital Hand-Held "Pocket" Potassium Phosphate Refractometer, 0.0 to 15.0% Range
Specifications
Model PAL-70S Cat.No. 4470 Scale Potassium phosphate
TemperatureMeasurement Range Potassium phosphate :0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Potassium phosphate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium phosphate : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4431 PAL-31S Digital Hand-Held Pocket Formic Acid Refractometer, 0.0 to 20.0% Range
Specifications
Model PAL-31S Cat.No. 4431 Scale Formic acid (g/100g)
TemperatureMeasurement Range Formic acid : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Formic acid : 0.5%
Temperature : 0.1゚CMeasurement Accuracy Formic acid : ±1.0%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4451 PAL-51S Digital Hand-Held Pocket Sodium Bromide Refractometer, 0.0 to 30.0% Range
Specifications
Model PAL-51S Cat.No. 4451 Scale Sodium bromide (g/100g)
TemperatureMeasurement Range Sodium bromide : 0.0 to 30.0%
Temperature : 10.0 to 40.0゚CResolution Sodium bromide : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium bromide : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4466 PAL-66S Digital Hand-Held "Pocket" Potassium Oxalate Refractometer, 0.0 to 10.0% Range
Specifications
Model PAL-66S Cat.No. 4466 Scale Potassium oxalate (g/100g)
TemperatureMeasurement Range Potassium oxalate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Potassium oxalate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium oxalate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4468 PAL-68S Digital Hand-Held "Pocket" Potassium Dichromate Refractometer, 0.0 to 15.0% Range
Specifications
Model PAL-68S Cat.No. 4468 Scale Potassium dichromate (g/100g)
TemperatureMeasurement Range Potassium dichromate : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Potassium dichromate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium dichromate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world -
Atago 4472 PAL-72S Digital Hand-Held "Pocket" Sodium Tungstate Refractometer, 0.0 to 10.0% Range
Specifications
Model PAL-72S Cat.No. 4472 Scale Sodium tungstate (g/100g)
TemperatureMeasurement Range Sodium tungstate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Sodium tungstate : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Sodium tungstate : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4452 PAL-52S Digital Hand-Held Pocket Potassium Iodide Refractometer, 0.0 to 30.0% Range
Specifications
Model PAL-52S Cat.No. 4452 Scale Potassium iodide (g/100g)
TemperatureMeasurement Range Potassium iodide : 0.0 to 30.0%
Temperature : 10.0 to 40.0゚CResolution Potassium iodide : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium iodide : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4471 PAL-71S Digital Hand-Held "Pocket" Sodium Molybdate Refractometer, 0.0 to 10.0% Range
Specifications
Model PAL-71S Cat.No. 4471 Scale Sodium molybdate (g/100g)
TemperatureMeasurement Range Sodium molybdate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Sodium molybdate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium molybdate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4443 PAL-43S Digital Hand-Held "Pocket" Magnesium Chloride Refractometer, Magnesium Chloride : 0.0 to 30.0%
Specifications
Model PAL-43S Cat.No. 4443 Scale Magnesium chloride
TemperatureMeasurement Range Magnesium chloride : 0.0 to 30.0%
Temperature : 10.0 to 40.0゚CResolution Magnesium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Magnesium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4432 PAL-32S Digital Hand-Held "Pocket" Phosphoric Acid Refractometer, Phosphoric acid : 0.0 to 20.0%
Specifications
Model PAL-32S Cat.No. 4432 Scale Phosphoric acid (g/100g)
TemperatureMeasurement Range Phosphoric acid : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Phosphoric acid : 0.2%
Temperature : 0.1゚CMeasurement Accuracy Phosphoric acid : ±0.4%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4464 PAL-64S Digital Hand-Held "Pocket" Sodium bicarbonate Refractometer, Sodium bicarbonate : 0.0 to 10.0%
Specifications
Model PAL-64S Cat.No. 4464 Scale Sodium bicarbonate (g/100g)
TemperatureMeasurement Range Sodium bicarbonate : 0.0 to 10.0%
Temperature : 10.0 to 40.0゚CResolution Sodium bicarbonate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium bicarbonate : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4465 PAL-65S Digital Hand-Held "Pocket" Sodium tartrate Refractometer, Sodium tartrate :0.0 to 25.0%
Specifications
Model PAL-65S Cat.No. 4465 Scale Sodium tartrate (g/100g)
TemperatureMeasurement Range Sodium tartrate :0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Sodium tartrate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium tartrate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4463 PAL-63 Digital Hand-Held "Pocket" Sodium Carbonate Refractometer PAL Series, 0.0 to 15.0% Range
Specifications
Model PAL-63S Cat.No. 4463 Scale Sodium carbonate (g/100g)
TemperatureMeasurement Range Sodium carbonate : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Sodium carbonate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium carbonate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4467 PAL-67 Digital Hand-Held "Pocket" Potassium Chromate Refractometer PAL Series, 0.0 to 20.0% Range
Specifications
Model PAL-67S Cat.No. 4467 Scale Potassium chromate (g/100g)
TemperatureMeasurement Range Potassium chromate : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Potassium chromate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium chromate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world -
Atago 4469 PAL-69 Digital Hand-Held "Pocket" Sodium Thiosulfate Refractometer PAL Series, 0.0 to 20.0% Range
Specifications
Model PAL-69S Cat.No. 4469 Scale Sodium thiosulfate (g/100g)
TemperatureMeasurement Range Sodium thiosulfate : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Sodium thiosulfate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Sodium thiosulfate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world -
Atago 4487 PAL-87S Digital Hand-Held "Pocket" Wine Refractometer PAL Series, Oe (Oechsle) : 0 to 240° and Brix : 0.0 to 53.0% Range
Specifications
Model PAL-87S Cat.No. 4487 Scale Oe (Oechsle)
Brix
TemperatureMeasurement Range Oe (Oechsle) : 0 to 240°
Brix : 0.0 to 53.0%
Temperature : 10.0 to 40.0°CResolution Oe (Oechsle) : 1°
Brix : 0.1%
Temperature : 0.1°CMeasurement Accuracy Oe (Oechsle) : ± 1°
Brix : ± 0.2%
Temperature : ±1°CTemperature compensation range 10 to 40°C (Automatic Temperature Compensation) Ambient Temperature 10 to 40°C Measurement Time 3 seconds Power Supply 2 × AAA Batteries International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 5.5×3.1×10.9cm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· STRAP : RE-39410
* Calibration Certificate : Contact an ATAGO representative for details.
-
Atago 4454 PAL-54S Digital Hand-Held "Pocket" Copper Sulfate Refractometer PAL Series, 1.000 to 1.210 Range
Specifications
Model PAL-54S Cat.No. 4454 Scale Copper sulfate (S.G.)
TemperatureMeasurement Range Copper sulfate (S.G.) : 1.000 to 1.210
Temperature : 10.0 to 40.0゚CResolution Copper sulfate (S.G.) : 0.001
Temperature : 0.1゚CMeasurement Accuracy Copper sulfate (S.G.) : ±0.002
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4393 PAL-03CS Digital Hand-Held "Pocket" Sodium Chloride Refractometer , Measure the concentration and freezing point of brine
Specifications
Model PAL-03CS Cat.No. 4393 Scale Sodium chloride (g/100g)
Freezing point
TemperatureMeasurement Range Sodium chloride : 0.0 to 28.0%
Freezing point : 0 to -22゚C
Temperature : 10.0 to 40.0゚CResolution Sodium chloride : 0.1%(g/100g)
Freezing point : -1゚C
Temperature : 0.1゚CMeasurement Accuracy Sodium chloride : ±0.2%(g/100g)
Freezing point : 1゚C
Temperature : ±1゚CTemperature compensation range 10 to 40゚C Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) -
Atago 4444 PAL-44S Digital Hand-Held "Pocket" Lithium Chloride Refractometer PAL Series, 0.0 to 20.0% Range
Specifications
Model PAL-44S Cat.No. 4444 Scale Lithium chloride (g/100g)
TemperatureMeasurement Range Lithium chloride : 0.0 to 20.0%
Temperature : 10.0 to 40.0゚CResolution Lithium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Lithium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4445 PAL-45S Digital Hand-Held "Pocket" Barium Chloride Refractometer PAL Series, 0.0 to 25.0% Range
Specifications
Model PAL-45S Cat.No. 4445 Scale Barium chloride (g/100g)
TemperatureMeasurement Range Barium chloride : 0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Barium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Barium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4446 PAL-46S Digital Hand-Held "Pocket" Cobalt Chloride Refractometer PAL Series, 0.0 to 15.0% Range
Specifications
Model PAL-46S Cat.No. 4446 Scale Cobalt chloride (g/100g)
TemperatureMeasurement Range Cobalt chloride : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Cobalt chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Cobalt chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4447 PAL-47S Digital Hand-Held "Pocket" Ferric Chloride Refractometer PAL Series, 0.0 to 15.0% Range
Specifications
Model PAL-47S Cat.No. 4447 Scale Ferric chloride (g/100g)
TemperatureMeasurement Range Ferric chloride : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Ferric chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Ferric chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4448 PAL-48S Digital Hand-Held "Pocket" Strontium Chloride Refractometer PAL Series, 0.0 to 25.0% Range
Specifications
Model PAL-48S Cat.No. 4448 Scale Strontium chloride (g/100g)
TemperatureMeasurement Range Strontium chloride : 0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Strontium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Strontium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4449 PAL-49S Digital Hand-Held "Pocket" Potassium Chloride Refractometer PAL Series, 0.0 to 30.0% Range
Specifications
Model PAL-49S Cat.No. 4449 Scale Potassium chloride (g/100g)
TemperatureMeasurement Range Potassium chloride : 0.0 to 30.0%
Temperature : 10.0 to 40.0゚CResolution Potassium chloride : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium chloride : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40°C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4450 PAL-50S Digital Hand-Held "Pocket" Potassium Bromide Refractometer PAL Series, 0.0 to 35.0% Range
Specifications
Model PAL-50S Cat.No. 4450 Scale Potassium bromide (g/100g)
TemperatureMeasurement Range Potassium bromide : 0.0 to 35.0%
Temperature : 10.0 to 40.0゚CResolution Potassium bromide : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium bromide : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement (when alkaline batteries are used) International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4455 PAL-55S Digital Hand-Held "Pocket" Magnesium Sulfate Refractometer PAL Series, 0.0 to 25.0% Range
Specifications
Model PAL-55S Cat.No. 4455 Scale Magnesium sulfate (g/100g)
TemperatureMeasurement Range Magnesium sulfate : 0.0 to 25.0%
Temperature : 10.0 to 40.0゚CResolution Magnesium sulfate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Magnesium sulfate : ±0.2%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world. -
Atago 4456 PAL-56S Digital Hand-Held "Pocket" Potassium Sulfate Refractometer PAL Series, 0.0 to 15.0% Range
Specifications
Model PAL-56S Cat.No. 4456 Scale Potassium sulfate (g/100g)
TemperatureMeasurement Range Potassium sulfate : 0.0 to 15.0%
Temperature : 10.0 to 40.0゚CResolution Potassium sulfate : 0.1%
Temperature : 0.1゚CMeasurement Accuracy Potassium sulfate : ±0.3%
Temperature : ±1゚CTemperature compensation range 10 to 40゚C
(Automatic Temperature Compensation)Ambient Temperature 10 to 40゚C Sample Volume 0.3 mL Measurement Time 3 seconds Power Supply 2 x AAA Batteries Battery Life Approx. 11,000 times measurement
(when alkaline batteries are used)International Protection Class IP65 Dust-tight and Protected against water jets. Dimensions & Weight 55(W) x 31(D) x 109(H)mm, 100g (Main Unit only) Options
· PAL-CASE : RE-39409
· PAL Silicone Cover : RE-39413
· STRAP : RE-39410
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world.
80 products found
Sort by:
Recommended