More search options
36 products found
  • Daicel 80256 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 50mm, 20µm
    • Free Mainland UK Shipping

    Daicel 80256 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 50mm, 20µm

    CHIRALPAK ® IA-3 / CHIRALPAK ® IA

    Silica gel surface covalently bonded amylose-tris (3,5-dimethylphenylcarbamate)

    IA solvent-resistant chiral column, silica gel surface covalent bond with amylose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    Price Upon Application Or Discontinued
  • Daicel 80266 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 100mm, 20µm
    • Free Mainland UK Shipping

    Daicel 80266 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 100mm, 20µm

    CHIRALPAK ® IA-3 / CHIRALPAK ® IA

    Silica gel surface covalently bonded amylose-tris (3,5-dimethylphenylcarbamate)

    IA solvent-resistant chiral column, silica gel surface covalent bond with amylose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    Price Upon Application Or Discontinued
  • Daicel 80S25 CHIRALPAK ®  IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 250mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S25 CHIRALPAK ® IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 250mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 80S94 CHIRALPAK ®  IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 150mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S94 CHIRALPAK ® IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 150mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 80S95 CHIRALPAK ®  IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 250mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S95 CHIRALPAK ® IA-3 SFC Analytical Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 250mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 80U82 CHIRALPAK ® IA-U Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 3.0mm, 50mm, 1.6µm
    • Free Mainland UK Shipping

    Daicel 80U82 CHIRALPAK ® IA-U Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 3.0mm, 50mm, 1.6µm


    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    IA solvent-resistant chiral column, the amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of the silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1300.00
  • Daicel 80U83 CHIRALPAK ® IA-U Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 3.0mm, 100mm, 1.6µm
    • Free Mainland UK Shipping

    Daicel 80U83 CHIRALPAK ® IA-U Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 3.0mm, 100mm, 1.6µm


    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    IA solvent-resistant chiral column, the amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of the silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1780.00
  • Daicel 80S22 CHIRALPAK ®  IA-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S22 CHIRALPAK ® IA-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 80S24 CHIRALPAK ®  IA-3 SFC Supercritical Fluid Chromatography olysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column,  4.6mm, 150mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S24 CHIRALPAK ® IA-3 SFC Supercritical Fluid Chromatography olysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 80S23 CHIRALPAK ®  IA-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm
    • Free Mainland UK Shipping

    Daicel 80S23 CHIRALPAK ® IA-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm

    IA.JPG

    The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)

    CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.

    Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.

    Examples of solvents that can be used:

    The main mobile phase: CO 2

    Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%

    Price Upon Application Or Discontinued
  • Daicel 00011 Cartridge Holder , 4.0mm Inner Diameter, 10mm Length
    • Free Mainland UK Shipping
    • £172.00
  • Daicel 81321 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 50mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81321 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 50mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    Price Upon Application Or Discontinued
  • Daicel 81323 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 100mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81323 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 100mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1430.00
  • Daicel 81324 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 150mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81324 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 150mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81325 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81325 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81394 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 150mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81394 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 150mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81311 CHIRALPAK ® IB Guard Cartridge (Pack of 3) - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4mm, 10mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81311 CHIRALPAK ® IB Guard Cartridge (Pack of 3) - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4mm, 10mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £375.00
  • Daicel 81375 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 30mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81375 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 30mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    Price Upon Application Or Discontinued
  • Daicel 81355 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 50mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81355 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 50mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    Price Upon Application Or Discontinued
  • Daicel 81322 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 50mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81322 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 50mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1050.00
  • Daicel 81335 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81335 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £5479.00
  • Daicel 81345 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 20mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81345 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 20mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £10295.00
  • Daicel 81337 CHIRALPAK ® IB Guard Semi Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm
    • Free Mainland UK Shipping

    Daicel 81337 CHIRALPAK ® IB Guard Semi Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1589.00
  • Daicel 81522 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81522 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1050.00
  • Daicel 81523 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81523 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1430.00
  • Daicel 81525 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 250mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81525 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 250mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81592 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 50mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81592 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 50mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1050.00
  • Daicel 81593 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 100mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81593 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 100mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1430.00
  • Daicel 81594 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 150mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81594 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 150mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81595 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 250mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81595 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 250mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81524 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81524 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1790.00
  • Daicel 81511 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Chiral Guard Cartridges (Pack of 3), 4mm, 10mm, 3µm
    • Free Mainland UK Shipping

    Daicel 81511 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Chiral Guard Cartridges (Pack of 3), 4mm, 10mm, 3µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £375.00
  • Daicel 81U82 CHIRALPAK ® IB-U Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column,  50mm, 3mm, 1.6µm
    • Free Mainland UK Shipping

    Daicel 81U82 CHIRALPAK ® IB-U Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 50mm, 3mm, 1.6µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1300.00
  • Daicel 81U83 CHIRALPAK ® IB-U Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 100mm, 3mm, 1.6µm
    • Free Mainland UK Shipping

    Daicel 81U83 CHIRALPAK ® IB-U Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 100mm, 3mm, 1.6µm

    Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)

    IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).

    Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.

    Solvents that can be used, for example:

    Positive phase: n-Hexane, IPA, EtOH

    Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE

    Reverse phase: H 2 O, IPA, MeOH

    • £1780.00