Statebourne Cryogenics 9916051 Biosystem Access 50, LN2 Capacity (litres) Vapour/Liquid 150/762, with Automatic Level Control and Temperature Monitoring
Wide-neck easy access and Bulk Biobanks with automatic level control and temperature data-logging.
The Biosystem 12, 24 and 50 models are designed to provide frequent-access users with rapid specimen storage and retrieval. Every Biosystem Access series container can be configured for either liquid (-196°C), or Vapour phase storage.
Specifications
LN2 Capacity (litres) Vapour/Liquid 150/762 Internal usable height mm 910 Internal usable diameter mm 1130 Weight Empty (Kg) 370 Weight Full (nitrogen) excluding ICS (kg) 986 Overall height (lid closed) mm 1320 Lid opening height mm 2685 Overall width mm 1250 Overall depth mm 1645 -
Statebourne Cryogenics 5801252 Biosystem 24 ICS - Liquid Phase, Cell Cryoboxes, numbered racks (24,050)
Specifications
LN2 Capacity (litres) Vapour/Liquid 32/178 Internal usable height mm 745 Internal usable diameter mm 617 Weight Empty (Kg) 202 Weight Full (nitrogen) excluding ICS (kg) 346 Overall height (lid closed) mm 1077 Lid opening height mm 1750 Overall width mm 741 Overall depth mm 900 -
Statebourne Cryogenics 5801253 Biosystem 24 ICS - Vapour Phase, Cell Cryoboxes, numbered racks (20,350)
Specifications
LN2 Capacity (litres) Vapour/Liquid 32/178 Internal usable height mm 745 Internal usable diameter mm 617 Weight Empty (Kg) 202 Weight Full (nitrogen) excluding ICS (kg) 346 Overall height (lid closed) mm 1077 Lid opening height mm 1750 Overall width mm 741 Overall depth mm 900 -
Statebourne Cryogenics 9916025-1 Biosystem Arctic 12 , Automatic liquid nitrogen refrigerators for storage, Stores 10,250 x 2ml vials in vapour phase – reservoir 32 litres
ACCESS and ARCTIC. Frequent-access with rapid specimen storage & retrieval
The Biosystem 12, 24 and 50 models are designed to provide frequent-access users with rapid specimen storage and retrieval. Access Biosystem units are for storage in wide neck dewars for easy access. Arctic Biosystems units are designed for ultra cold vapour phase storage in ‘Dry’ chamber. Every Biosystem Access series container can be configured for either liquid (-196°C), or Vapour phase storage.
- Stores samples in ‘Dry’ vapour phase at -190C at top of rack
- Stores 10,250 x 2ml vials in vapour phase – reservoir 32 litres
- LN2 can be accessed and check, and vessel can be easily re-filled with LN2
- Racks are only 10 boxes and sit on a plinth for easier lifting (shorter lift height)
- Open design for accessing all sample racks
- All metal lid for extra longevity with new long lasting spring hinges
- New all plastic lid plug that is smooth to allow easier removal of ice
- New lid seal that holds firmer but can be changed in minutes
- All metal top plate no plastic parts touching LN2
- All control sensors inside vacuum space for better protection from over enthusiastic users
- Twin fill solenoids as standard for extra overfill protection
- Access for external temperature probe makes it easier for HTA storage
- Lockable lid with key
- Small size only 741 mm wide
- 5 Year warranty on vacuum, 1 year on electrics and valves
- Supply tank recommended – Cryostor 180 supply tank
-
Statebourne Cryogenics 9916060-1 Biosystem Arctic 24 , Automatic liquid nitrogen refrigerators for storage, Stores 20,350 x 2ml vials in vapour phase – reservoir 49 litres
ACCESS and ARCTIC. Frequent-access with rapid specimen storage & retrieval
The Biosystem 12, 24 and 50 models are designed to provide frequent-access users with rapid specimen storage and retrieval. Access Biosystem units are for storage in wide neck dewars for easy access. Arctic Biosystems units are designed for ultra cold vapour phase storage in ‘Dry’ chamber. Every Biosystem Access series container can be configured for either liquid (-196°C), or Vapour phase storage.
- Stores samples in ‘Dry’ vapour phase at -190C at top of rack
- Stores 20,350 x 2ml vials in vapour phase – reservoir 49 litres
- LN2 can be accessed and check, and vessel can be easily re-filled with LN2
- Racks are only 11 boxes and sit on a plinth for easier lifting (shorter lift height)
- Open design for accessing all sample racks
- All metal lid for extra longevity with new long lasting spring hinges
- New all plastic lid plug that is smooth to allow easier removal of ice
- New lid seal that holds firmer but can be changed in minutes
- All metal top plate no plastic parts touching LN2
- All control sensors inside vacuum space for better protection from over enthusiastic users
- Twin fill solenoids as standard for extra overfill protection
- Access for external temperature probe makes it easier for HTA storage
- Lockable lid with key
- Small size only 741 mm wide
- 5 Year warranty on vacuum, 1 year on electrics and valves
- Supply tank recommended – Cryostor 240 supply tank
- OPTION – Vapour guard overflow protection system
-
Statebourne Cryogenics 9916051-1 Biosystem Arctic 50 , Automatic liquid nitrogen refrigerators for storage, Stores 50,700 x 2ml vials in vapour phase – reservoir 150 litres
ACCESS and ARCTIC. Frequent-access with rapid specimen storage & retrieval
The Biosystem 12, 24 and 50 models are designed to provide frequent-access users with rapid specimen storage and retrieval. Access Biosystem units are for storage in wide neck dewars for easy access. Arctic Biosystems units are designed for ultra cold vapour phase storage in ‘Dry’ chamber. Every Biosystem Access series container can be configured for either liquid (-196°C), or Vapour phase storage.
- Stores samples in ‘Dry’ vapour phase at -190C at top of rack
- Stores 50,700 x 2ml vials in vapour phase – reservoir 150 litres
- LN2 can be accessed and checked, and vessel can be easily re-filled with LN2
- Racks are only 13 boxes and sit on a plinth for easier lifting (shorter lift height)
- Open design for accessing all sample racks
- All metal lid for extra longevity with new long lasting spring hinges
- New all plastic lid plug that is smooth to allow easier removal of ice
- New lid seal that holds firmer but can be changed in minutes
- All metal top plate no plastic parts touching LN2
- All control sensors inside vacuum space for better protection from over enthusiastic users
- Twin fill solenoids as standard for extra overfill protection
- Access for external temperature probe makes it easier for HTA storage
- Lockable lid with key
- Small size only 741 mm wide
- 5 Year warranty on vacuum, 1 year on electrics and valves
- Supply tank recommended – Cryostor 300 supply tank
- OPTION vapour-guard anti overflow system
-
Statebourne Cryogenics 9916092 Biosystem 21 Archive Cryogenic Refrigerator - High capacity sample storage for the low consumption of LN2
The Biosystem 21, 40, 80 and 100 models are designed to maximise economic operation with highest capacity sample storage for the lowest possible consumption of liquid nitrogen. Every Biosystem Archive-Series refrigerator incorporates the “Vapour Guard” which guarantees that liquid can never come into contact with samples.
Specifications
2ML Cryovials 21,000
LN2 Capacity (litres) vapour phase (Gross internal volume litres) 81/(440)
Internal storage drum height mm 785
Internal storage drum diameter mm 750
Weight Empty (Kg) 356
Weight Full (nitrogen) excluding ICS (kg) 711
Overall height (lid closed) mm 1433
Overall Diameter (mm) 897
7 products found
Sort by:
Recommended