Hanna HI-96759 Maple Syrup Portable Photometer
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.Battery powered – Allows use away from a power source. Batteries are included with all battery operated products. Specifications
Range 0.0 to100.0% transmittance Resolution 0.1% transmittance Precision ±1% to 75% transmittance Light Source Tungsten lamp Light Detector Silicon photocell with narrow band interference filter 560 nm Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Power Supply (1) 9V battery Auto-off After 10 minutes of non-use Dimensions 193 x 104 x 69 mm Weight 360g Method Direct Measure Ordering information: The HI-96759 is supplied with square cuvettes (6), light shield cap, 5ml syringes (2), 30ml bottle of glycerol, cuvette wiping cloth, 9v battery, instrument quality certificate, instruction manual and rigid carrying case. Solutions and accessories (sold separately) HI-93703-57 Glycerol (4), 30ml; HI-93703-50 Cuvette cleaning solution, 230ml; HI-93703-56 consists of 82 matched square cuvettes, glycerol standard (30ml) and 5ml syringes (2) (75 tests average) -
Hanna HI-83399 Water and Wastewater Multi-Parameter with COD Photometer & pH Meter
One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.
40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. -
Hanna HI-83314-02 Multi-parameter Wastewater & Water Photometer with COD and pH meter
One meter can be used for both photometric and pH measurements. HI-83314 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. Ten key water and wastewater quality parameters with 20 different methods.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83314 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. -
WTW 250024D Filter photometer photoLab® S12 with 12 wavelengths, reference beam technology for 16 mm round cells and 10, 20, 50 mm rectangular cells
Specifications
Applications / Application fields Routine measurements in waste and drinking water, wide-ranging laboratory testing tasks, field use optional Wavelengths 340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm Opticalsystem Filter/reference beam Special functions Kinetics Custom methods 50 Cuvettes Round and rectangular 10, 20, 50 mm -
WTW 250026D Filter photometer photoLab® S12 with 12 wavelengths, rechargeable battery version, reference beam technology for 16 mm round cells and 10, 20, 50 mm rectangular cells
Specifications
Applications / Application fields Routine measurements in waste and drinking water, wide-ranging laboratory testing tasks, field use optional Wavelengths 340, 410, 445, 500, 525, 550, 565, 605, 620, 665, 690, 820 nm Opticalsystem Filter/reference beam Special functions Kinetics Custom methods 50 Cuvettes Round and rectangular 10, 20, 50 mm -
Hanna Instruments HI-93414-11 Calibration Set for Turbidity Meters
The HI-93414-11 Free and Total Chlorine CAL Check™ Standards provide a simple solution to calibrating and validating compatible benchtop and portable photometers.
This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying compatible free and total chlorine photometers
-
Hanna Instruments HI-740036P 10 x 100ml Beaker (10 pieces)
The HI-740036P is a set of 10 plastic beakers, 100 mL. The beakers are for use during testing with Hanna chemical test kits and photometers. Anti-spill ported caps are available separately.
-
WTW 251301 LS Flex/430 LabStation for easy lab use with Software Package
- LSdata Flex/430 for GLP-compliant data handling, null modem cable, rechargeable batteries, universal plug including loading function, RS232 Interface. Suitable for all pHotoFlex® and Turb® 430 models; use of bar code reader possible.
-
WTW 902762 LSdata Flex/430 photoLab® color + photoLab® data spectral PC- Software Package
- replaces former photoLab Data spectral (order number 902761). CIE based color measurement (LAB, Luv…), Hazen (Pt-Co), Yellowness, Gardner etc. for photoLab® 7000 series together with GLP-compliant data management and export into LIMS.
-
WTW 902763 photoLab® color + photoLab® data spectral PC-software package
- Intuitive user interface
- GLP-compliant for AQA and LIMS transmission
- Photometric color measurement
Technical Data
Software requirements Operating system Microsoft® Windows® 7 /or Windows® 8 Synchronization software Microsoft® Mobile Device Center for Windows® 7 /or Windows® 8 -
Hanna Instruments HI-93703-53 Chlorine Remover , Dropper Bottle
Reagent for reducing chlorine concentrations when using the the HI-96729 Fluoride Portable photometer. -
WTW 250040 KK/S6-12 Case for photoLab® S6/photoLab® S12
- with foam insert, not equipped, measure WxHxD: 540 x 430 x 200 mm
-
WTW 251304 FC pHotoFlex/Turb 430 Field case with table insert to hold instrument, stand and cuvettes for easy field handling
- Additional space to hold accessories and pipette
-
Hanna Instruments HI-93703-50 Cuvette Cleaning Solution, 230ml
HI-93703-50 is an alcohol based cleaning solution for cuvettes/vials used in photometers and turbidity meters. This anti-static solution ensures the glass cuvette used for colorimetric and turbidimetric measurements remains clean and free from imperfections.
Specifications
Size 230ml Package Bottle Quantity 1 Certificate of Analysis No -
Hanna Instruments HI-93711-01 Total Chlorine Reagent, DPD Method, 100 tests
The HI-93711-01 are reagents for the colorimetric determination of total chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package Packets Quantity 100 tests Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between total chlorine and the reagents causes a pink tint in the sample. -
Hanna HI-839800 25 Vial Thermo-Reactor
The Hanna HI-839800 thermo-reactor is an easy to use test tube heater with the capacity to perform up to 25 simultaneous digestions. Complete with a countdown timer, it can be used for timed or infinity testing procedures.
Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.
-
Hanna Instruments HI-93716-03 Reagents for 300 bromine tests
The HI-93716-03 are reagents for the colorimetric determination of bromine using a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package packet Quantity 300 tests Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample. -
Hanna Instruments HI-93722-01 Cyanuric Acid Reagent, Turbidimetric Method
The HI-93722-01 are reagents for the colorimetric determination of cyanuric acid. There are enough reagents for 100 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package packets, bottle Quantity 100 tests Method Turbidimetric Method -
Hanna Instruments HI-93722-03 Reagents: 300 Cyanuric acid tests
The HI-93722-03 are reagents for the colorimetric determination of cyanuric acid. There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package packets, bottle Quantity 300 tests Method Turbidimetric Method -
Hanna Instruments HI-93710-03 pH Reagents, Phenol Red method, 300 pH tests
The HI-93710-03 are reagents for the colorimetric determination of pH. There are enough reagents for 300 tests to be used with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each bottle for traceability.
Specifications
Package Dropper bottle Quantity 300 tests Method Phenol red method -
Hanna Instruments HI-93746-03 Iron Low Range Reagents - 150 tests
The HI-93746-03 are reagents for the colorimetric determination of low range iron. There are enough reagents for 150 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package Packet Quantity 150 tests Method Adaptation of the TPTZ method -
Hanna Instruments HI-93746-01 Iron Low Range Reagents, TPTZ Method
The HI-93746-01 are reagents for the colorimetric determination of low range iron. There are enough reagents for 50 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiration date on each packet for traceability.
Specifications
Package Packet Quantity 50 tests Method Adaptation of the TPTZ method -
Hanna Instruments HI-93716-01 Bromine Reagent, DPD Method, 100 tests, Range 0.00 to 8.00 mg/L
The HI-93716-01 are reagents for the colorimetric determination of bromine using a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package packet Quantity 100 tests Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample. -
Hanna Instruments HI-93710-01 pH Reagent, Phenol Red Method, 100 tests
The HI-93710-01 are reagents for the colorimetric determination of pH. There are enough reagents for 100 tests to be used with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each bottle for traceability.
Specifications
Package Dropper bottle Quantity 100 tests Method Phenol red method -
Hanna Instruments HI-93711-03 Total Chlorine Reagent, DPD Method (300 tests)
The HI-93711-03 are reagents for the colorimetric determination of total chlorine. There are enough reagents for 300 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.Specifications
Package Packets Quantity 300 tests Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between total chlorine and the reagents causes a pink tint in the sample. -
Hanna Instruments HI-93718-01 Iodine Reagent, DPD Method, 100 tests
The HI-93718-01 are reagents for the colorimetric determination of iodine. There are enough reagents for 100 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package Packet Quantity 100 tests Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method. The reaction between iodine and the reagent causes a pink tint in the sample. -
Hanna Instruments HI-93718-03 Iodine Reagents, 300 tests
The HI-93718-03 are reagents for the colorimetric determination of iodine (I2). There are enough reagents for 300 tests to be used with a compatible benchtop or portable photometer. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Specifications
Package Packet Quantity 300 tests Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, DPD method. The reaction between iodine and the reagent causes a pink tint in the sample. -
Hanna Instruments HI-93701-01 Free Chlorine Reagent, DPD Method
The HI-93701-01 are reagents for the colorimetric determination of free chlorine. There are enough reagents for 100 tests and are for use with Hanna’s compatible benchtop and portable photometers. These high quality reagents are clearly marked with the lot number and expiry date on each packet for traceability.
Pre-made reagents for ease of use
Prepared with high purity chemicals
Specifications
Package packets Quantity 100 tests Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample.