Hanna Instruments HI-93703 Portable Turbidity Meter
This microprocessor based turbidity meter delivers laboratory grade accuracy for field or factory use.
Specifications
Range 0.00 to 50.00 FTU;
50 to 1000 FTUResolution 0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)Accuracy ±0.5 FTU or ±5% of reading (whichever is greater) Calibration 3 points (0 FTU, 10 FTU and 500 FTU) Light Source infrared LED Light Life Life of the instrument Light Detection Silicon Photocell Battery Type / Life 4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
automatic shut-off after 5 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") Weight 510 g (1.1 lb.) -
Hanna Instruments HI-93703C Portable Turbidity Meter Kit
This microprocessor based turbidity meter delivers laboratory grade accuracy for field or factory use. Supplied with a complete calibration and maintenance kit in a case.
Water resistant, easy to hold and with a simple three-point calibration process, it is ideal for water testing and has proved highly popular across the UK.
Specifications
Range 0.00 to 50.00 FTU;
50 to 1000 FTUResolution 0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)Accuracy ±0.5 FTU or ±5% of reading (whichever is greater) Calibration 3 points (0 FTU, 10 FTU and 500 FTU) Light Source infrared LED Light Life Life of the instrument Light Detection Silicon Photocell Battery Type / Life 4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
automatic shut-off after 5 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") Weight 510 g (1.1 lb.) -
Hanna Instruments HI-93414-11 Calibration Set for Turbidity Meters
The HI-93414-11 Free and Total Chlorine CAL Check™ Standards provide a simple solution to calibrating and validating compatible benchtop and portable photometers.
This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying compatible free and total chlorine photometers
-
Hanna Instruments HI-93124-03 Haze Turbidity Meter Calibration Kit
The HI-93124-03 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.
-
WTW 600325 Turb 430 T, Portable Turbidity Meter for Nephelometric Measurement
Specifications
Method Nephelometrisch (90° Straylight) Light Source Tungsten acc. to Standard Method US-EPA 180.1 Measuring Range 0-1100 FNU/NTU Resolution 0,01 for 0,00 -9,99 0,1 for 10 – 99,90 1 for 100 - 1100 Accuracy 0.01 NTU or +/- 2% of meas.value Reproducability < 0.5% Calibration Automatic, 3 Point Calibration Protocol yes Calibration Interval yes Data Storage 1000 values Response Time Ca. 3 s Cuvette 28 x 60 mm, 20 ml Sample Volume Ident Number yes Firmware-Update yes Interface RS 232, USB via Adapter (optional) Operation Temp. 0... +50°C Power Supply 4 Mignon (AA) > 3000 Measurements Rech.Batt. optional Data Management GLP compliant optional PC software LSdata LabStation+ PC-Software LSdata optional as small benchtop solution -
Hanna Instruments HI-93102 Multi Range Portable Turbidity Meter for Water Analysis
Measures Turbidity, free and total Chlorine, pH, Bromine, Iron, Iodine, and Cyanuric acid the most important parameters needed for water analysis, especially in drinking water.
Specifications
Range: Turbidity 0.00 to 9.99 NTU / 0.00 to 50.0 NTU Bromine 0.00 to 8.00 mg/L (ppm) Free Cl2 0.00 to 2.50 mg/L (ppm) Total Cl2 0.00 to 3.50 mg/L (ppm) CYS 0 to 80 mg/L (ppm) Iodine 0.0 to 12.5 mg/L (ppm) Iron LR 0.00 to 1.00 mg/L (ppm) pH 6.5 to 8.5 pH Resolution: Turbidity 0.01 and 0.1 NTU Bromine 0.01 mg/L (ppm) Free and Total Cl2 0.01 mg/L (ppm) CYS 1 mg/L (ppm) Iodine 0.1 mg/L (ppm) Iron LR 0.01 mg/L (ppm) pH 0.1 pH Accuracy @25°C: Turbidity ±0.5 NTU or ±5% of reading (whichever is greater) Bromine ±0.08 mg/L (ppm) ±3% of reading Free and Total Cl2 ±0.03 mg/L (ppm) ±3% of reading CYS ±1 mg/L (ppm) ±15% of reading Iodine ±0.1 mg/L (ppm) ±5% of reading pH ±0.1 pH Calibration two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) Light Source pure green LED Light Detector silicon photocell Battery Type / Life 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes Environment 0 to 50°C (32 to 122°F); RH max 95% (non condensing) Dimensions / Weight 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) -
Hanna Instruments HI-98713 ISO Portable Turbidity meter with Fast Tracker Technology
HI-98713 is a high accuracy ISO compliant portable turbidity meter that benefits from Hanna’s years of experience as manufacturer of analytical instruments.
The HI-98713 meets and exceeds the requirements of the ISO 7027 for water quality. The instrument is specially designed for water quality measurements, providing a reliable and accurate reading on low turbidity values. Ratio method with 90° and 180° light detector for accurate measurements
Specifications
Range 0.00 to 9.99 FTU
10.0 to 99.9 FTU
100 to 1000 FTURange Selection Automatically Resolution 0.01 FTU from 0.00 to 9.99 FTU
0.1 FTU from 10.0 to 99.9 FTU
1 FTU from 100 to 1000 FTUAccuracy ±2% of reading plus 0.1 FTU Repeatability ±1% of reading or 0.01 FTU, whichever is greater Stray Light < 0.1 FTU Typical EMC Deviation ±0.05 FTU Light Source 860 nm infrared LED IR Detector Silicon Photocell Method Adaptation of ISO 7027, ratio method with 90° and 180° detector. Display 60 x 90 mm LCD with backlight Standards < 0.1, 15, 100 and 750 FTU Calibration Two, three or four point calibration Logging Memory 200 records Serial Interface RS232 and USB 1.1 Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 4 x 1.5V AA alkaline batteries or AC adapter Auto Shut-off After 15 minutes of non-use Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) Weight 512 g (18 oz.) -
WTW 600325 Turb® 430 T / SET, Portable Turbidity Meter for Nephelometric Measurement
Specifications
Method Nephelometrisch (90° Straylight) Light Source Tungsten acc. to Standard Method US-EPA 180.1 Measuring Range 0-1100 FNU/NTU Resolution 0,01 for 0,00 -9,99 0,1 for 10 – 99,90 1 for 100 - 1100 Accuracy 0.01 NTU or +/- 2% of meas.value Reproducability < 0.5% Calibration Automatic, 3 Point Calibration Protocol yes Calibration Interval yes Data Storage 1000 values Response Time Ca. 3 s Cuvette 28 x 60 mm, 20 ml Sample Volume Ident Number yes Firmware-Update yes Interface RS 232, USB via Adapter (optional) Operation Temp. 0... +50°C Power Supply 4 Mignon (AA) > 3000 Measurements Rech.Batt. optional Data Management GLP compliant optional PC software LSdata LabStation+ PC-Software LSdata optional as small benchtop solution -
WTW 600321 Turb 430 IR/SET, Portable Turbidity Meter Set for Nephelometric Measurement
Specifications
Light source LED pH measurement yes Turbidity measurement yes Calibration interval/record yes Cal. adjustment for selected programs no Special methods with pH and Temp. yes User-defined progr. via LSdata Software 100 Data storage 1000 Sets available Rechargeable batteries w. universal plug optional Methods/programs ca. 200 Cells / Cuvettes: round 16 mm ( H:91-104 mm); 28 mm Ident number yes Interface RS232 PC-Connection yes Method-update via Internet yes Firmware-update via Internet yes LabStation for lab use incl. rechargeable battery + PC Software LSdata optional LSdata Stand alone optional optional Certificates CE/ETLus/cETL Waterproof housing IP 67 -
Hanna Instruments HI-88703-02 Bench Top Turbidity Meter EPA Compliant, Complete with cuvettes
PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet.Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz -
Hanna Instruments HI-88713-02 High Accuracy Bench Top Turbidity Meter, Complete with cuvettes
Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet. -
Hanna Instruments HI-93703-11 Portable ISO Compliant Turbidity Meter with Data Logging and PC Connectivity
The HI-93703-11 is a high accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI-93703-11 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements. Additionally, this meter contains a real-time clock and the capabilities to log measurements and transfer them to a PC using the HI-92000 software.
- Auto shut-off
- Positive-locking cuvette system ensures cuvette is firmly placed in the cell
- Logging and real time clock
Specifications
Turbidity Range 0.00 to 50.00;
50 to 1000Resolution 0.01 FTU (0.00 to 50.00 FTU);
1 FTU (50 to 1000 FTU)Accuracy ±0.5 FTU or ±5% of reading (whichever is greater) Calibration 3 points (0 FTU, 10 FTU and 500 FTU) Light Source infrared LED Light Life Life of the instrument Light Detection Silicon Photocell Battery Type / Life 4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
automatic shut-off after 5 minutes of non-useEnvironment 0 to 50°C (32 to 122°F); RH max 95% non-condensing Dimensions 220 x 82 x 66 mm (8.7 x 3.2 x 2.6") Weight 510 g (1.1 lb.) -
Hanna Instruments HI-83749-20 Bentocheck solution, 100ml, for use with the HI-83749-02 Turbidity meter
HI-83749-20 Bentocheck Solution is used to establish if bentonite fining agent is needed to stabilise wine. The solution is used with the HI-83749-02 Portable Turbidity and Bentocheck Meter which is designed to determine turbidity levels and protein stability in wine.
Specifications
Reagent Code Description HI-83749-20 Bentocheck, 100ml -
Hanna Instruments HI-98703 Precision Turbidity Portable Meter
The HI-98703 Precision Turbidity Portable Meter is specially designed for water quality measurements, providing reliable and accurate readings in the low turbidity range.
Specifications
Range 0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 1000 NTURange Selection Automatic Resolution 0.01 NTU from 0.00 to 9.99 NTU
0.1 NTU from 10.0 to 99.9 NTU
1 NTU from 100 to 1000 NTUAccuracy ±2% of reading plus 0.02 NTU Repeatibility ±1% of reading or 0.02 NTU, whichever is greater Stray Light < 0.02 NTU Light Source tungsten filament lamp Light Detector Silicon Photocell Method Ratio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B Standards < 0.1, 15, 100 and 750 FTU Calibration Two, three or four point calibration Logging Memory 200 records Serial Interface RS232 and USB Environment 0 to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 4 x 1.5V AA alkaline batteries or AC adapter Auto Shut-off After 15 minutes of non-use Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0") Weight 512 g (18 oz.) -
Hanna Instruments HI-83414-02 Turbidity and Free and Total Chlorine Meter
The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.
Specifications
Turbidity Range – non-ratio mode 0.00 to 9.99 NTU
10.0 to 40.0 NTU
0.0 to 99.9 NTU
100 to 268 Nephelos
0.0 to 9.80 EBCTurbidity resolution – non-ratio mode 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC Turbidity Range – ratio mode 0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 4000 NTU
0.0 to 99.9 NTU
100 to 26800 Nephelos
0.00 to 9.99 NTU
10.0 to 99.9
100 to 980 EBCTurbidity resolution – ratio mode 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC Free and Total Chlorine Range 0.00 to 5.00 mg/L Range Selection Automatic Free and Total Chlorine Resolution 0.01 mg/L from 0.00 to 3.50mg/L
0.10 above 3.50 mg/LTurbidity Accuracy ±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU Free and Total Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L Repeatability ±1% of reading or 0.02 NTU, whichever is greater Stray Light < 0.02 NTU Light Source tungsten filament lamp Light Detector Silicon Photocell Turbidity Method Ratio Nephelometric Method (90° and 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B Free and Total Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G Turbidity Standards < 0.1, 15, 100, 750 & 2000 NTU Free and Total Chlorine Standards 1.00 mg/L free chlorine, 1.00 mg/L total chlorine Turbidity Calibration Two, three, four or five point calibration Free and Total Chlorine Calibration one-point calibration Logging Memory 200 records Serial Interface USB Environment up to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 230 Vac adapter Auto Shut-off After 15 minutes of non-use Dimensions 230 x 200 x 145 mm Weight 2.5kg Order Information HI-83414-02 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-88703-11) and colorimeter (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, power cord and instruction manual. -
Hanna Instruments HI-93414-02 EPA Compliant Turbidity and Free & Total Chlorine Meter
The HI-93414 is a multiparameter instrument that measures the most important parameters in drinking water: turbidity and chlorine. The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences.
The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine
Specifications
Turbidity Range 0.00 to 9.99 NTU
10.0 to 99.9 NTU
100 to 1000 NTUFree and Total Chlorine Range 0.00 to 5.00 mg/L Range Selection Automatic Turbidity Resolution 0.01 NTU from 0.00 to 9.99 NTU
0.1 NTU from 10.0 to 99.9 NTU
1 NTU from 100 to 1000 NTUFree and Total Chlorine Resolution 0.01 mg/L from 0.00 to 3.50mg/L
0.10 above 3.50 mg/LTurbidity Accuracy ±2% of reading plus 0.02 NTU Free and Total Chlorine Accuracy ±0.03 mg/L ±3% of reading Repeatability ±1% of reading or 0.02 NTU, whichever is greater Stray Light < 0.02 NTU Light Source tungsten filament lamp Light Detector Silicon Photocell Turbidity Method Ratio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B Free and Total Chlorine Method Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample Turbidity Standards < 0.1, 15, 100 and 750 FTU Free and Total Chlorine Standards 1 mg/L free chlorine, 1 mg/L total chlorine Turbidity Calibration Two, three or four point calibration Free and Total Chlorine Calibration one-point calibration Logging Memory 200 records Serial Interface RS232 and USB Environment up to 50°C (32 to 122°F); max 95% RH non-condensing Power Supply 4 x 1.5V AA alkaline batteries or AC adapter Auto Shut-off After 15 minutes of non-use Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0") Weight 512 g (18 oz.) -
Hanna Instruments HI-98703-11 Turbidity Calibration Set for HI-98703
Turbidity calibration standards <0.1, 15, 100 and 750 NTU.
-
Hanna Instruments HI-98713-11 Turbidity Calibration Set for HI-98713
The HI-98713-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.
Supplied with Certificate of Analysis
- Product code
- Lot number
- Expiry date
- Standard value @ 25°C
- Reference meter NIST traceable
Provided storage containers
- Light tight
- Protects from accidental breakage
-
Hanna Instruments HI-93124-2 Turbidity Standard Solution 125 EBC
The HI-93124-2 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.
-
Hanna Instruments HI-93102-0 Turbidity Standard 0 NTU
The HI-93102-0 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.
Specifications
Description AMCO-AEPA-1 Calibration Solution at 0 NTU Bottle 30 mL -
WTW 600311 Turb® 355 IR Portable Turbidimeter with LED, Nephelometric Method
Specifications
Method Nephelometric (90° Straylight) Light Source IR LED acc. to Standard Method DIN 27027 / ISO 7027 Measuring Range 0-1100 FNU+NTU Resolution 0,01 for 1 -9,99 0,1 for 10 – 99,90 1 for 100 - 1100 Accuracy +/- 2% of value or +/-0.01 last decimal pos.for 1-500 NTU +/- 3% of meas. Value from 500-1100 NTU Reproducibility +/- 1% of meas.val. or +/-0.01 NTU Calibration Automatic 1-3 Point Calibration Protocol no Calibration Interval no Data Storage no Response Time Ca. 14 s Cuvette 25 x 45 mm, 15 ml sample volume Ident Number no Firmware-Update no Interface no Operation Temp. 0... +50°C Power Supply 4 Mignon (AAA) > 3000 Measurements Rech.Batt. no -
WTW 600312 Turb® 355 T Portable Turbidimeter with Tungsten Lamp
Specifications
Method Nephelometric (90° Straylight) Light Source Tungsten acc. to Standard Method US-EPA 180.1 Measuring Range 0-1100 FNU+NTU Resolution 0,01 for 1 -9,99 0,1 for 10 – 99,90 1 for 100 - 1100 Accuracy +/- 2% of value or +/-0.01 last decimal pos.for 1-500 NTU +/- 3% of meas. Value from 500-1100 NTU Reproducibility +/- 1% of meas.val. or +/-0.01 NTU Calibration Automatic 1-3 Point Calibration Protocol no Calibration Interval no Data Storage no Response Time Ca. 14 s Cuvette 25 x 45 mm, 15 ml sample volume Ident Number no Firmware-Update no Interface no Operation Temp. 0... +50°C Power Supply 4 Mignon (AAA) > 3000 Measurements Rech.Batt. no -
Hanna Instruments HI-83749-11 Turbidity Calibration Kit for use with HI-83749-02
The HI-83749-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating the HI-83749 Portable Turbidity and Bentonite check Meter. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.
-
Hanna Instruments HI-93703-50 Cuvette Cleaning Solution, 230ml
HI-93703-50 is an alcohol based cleaning solution for cuvettes/vials used in photometers and turbidity meters. This anti-static solution ensures the glass cuvette used for colorimetric and turbidimetric measurements remains clean and free from imperfections.
Specifications
Size 230ml Package Bottle Quantity 1 Certificate of Analysis No -
Hanna Instruments HI-93124-0 Standard Solution 0 EBC
The HI-93124-0 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.
-
Hanna Instruments HI-93124-1 Standard Solution 2.5 EBC
The HI-93124-1 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.
Specifications
Package Standard solution: 2.5 EBC (30ml bottle) Quantity 1 bottle Applications Beer Analysis, beverage -
Hanna Instruments HI-93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU
AMCO-EPA solution @ 500 FTU (30 mL)
The HI-93703-05 Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.
Specifications
Description AMCO-AEPA-1 Calibration Solution at 500 FTU Bottle 30 mL -
Hanna Instruments HI-93703-10 AMCO-AEPA-1 Calibration Solution at 10 FTU
AMCO-EPA solution @ 10 FTU (30 mL)
The HI-93703-10 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.
Specifications
Description AMCO-AEPA-1 Calibration Solution at 10 FTU Bottle 30 mL -
Hanna Instruments HI-93703-0 AMCO-AEPA-1 Calibration Solution at 0 FTU
AMCO-EPA solution @ 0 FTU (30 mL).
The HI-93703-0 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.
Specifications
Description AMCO-AEPA-1 Calibration Solution at 0 FTU Bottle 30 mL -
WTW 2FD57V Multi 3630 IDS SET KS2 Multi-Parameter Portable Meter MultiLine
Measure three parameters simultaneously –pH, ORP, dissolved oxygen, conductivity and/or turbidity with the digital pocket meter Multi 3630 IDS
- Wireless ready
- Measure, display and document three parameters plus secondary information
- Digital sensor detection -
WTW 2FD570 Multi-Parameter Portable Meter MultiLine® Multi 3630 IDS
Technical Data
Measuring ranges Depending on the respective IDS sensor Display LCD color graphic, backlit Data memory manual 500 / 10000 automatic Measuring channels 3 Protection class IP 67 Interfaces Mini-USB-B, USB-A Power supply Wide range power supply, 4x 1.2 V NiMH battery or via Mini USB-B -
WTW 2FD57F Multi-Parameter Portable Meter MultiLine® Multi 3630 IDS SET F contains SenTix® 940, FDO® 925, TetraCon® 925
Measure three parameters simultaneously – pH, ORP, dissolved oxygen, conductivity and/or turbidity with the digital pocket meter Multi 3630 IDS
- Wireless ready
- Measure, display and document three parameters plus secondary information
- Digital sensor detection
- Three galvanically isolated sensor inputs
Technical DataMeasuring ranges Depending on the respective IDS sensor Display LCD color graphic, backlit Data memory manual 500 / 10000 automatic Measuring channels 3 Protection class IP 67 Interfaces Mini-USB-B, USB-A Power supply Wide range power supply, 4x 1.2 V NiMH battery or via Mini USB-B Full Description
Multi 3630 IDS SET F- Professional wireless ready digital multi meter for portable field measurements, with three channel input, colour graphic display inc datalogger and USB interfaces. Single instrument in case with buffer 4 and 7, 3 mol/l KCL conductivity standard, short instruction manual, CD-ROM, rechargeable batteries driver software for USB, cable and universal power supply. Set includes meter in field case with IDS sensors: digital pH electrodes SenTix 940, digital conductivity cell TetraCon 925, optical DO probe FDO 925 and QSC Kit
-
WTW 600700 VisoTurb 900-P IDS Turbidity Sensors with Universal Plug Head
Digital turbidity sensor for the IDS system
Digital IDS turbidity measurement with a practical turbidity sensor for mobile applications in surface waters and process - the VisoTurb® 900-P
- Convenient turbidity sensor for MultiLine® IDS for measurements on site
- Easy 2 or 3 point calibration
- Suitable for multi-parameter measurements -
WTW 2FD353 Multi 3510 IDS SET 3 Multi-Parameter Portable Meter
Measuring range Measuring range of the IDS sensor Display LCD graphic, backlit Memory manual 500 / 4500 automatic Measurement channel 1 Protection class IP 67 Power supply 4 x 1,5 V AA (supplied) 4x 1,2 V NiMH-Akku or via USB port -
WTW 2FD350 Multi 3510 IDS Multi-Parameter Portable Meter MultiLine
Measuring range Measuring range of the IDS sensor Display LCD graphic, backlit Memory manual 500 / 4500 automatic Measurement channel 1 Protection class IP 67 Power supply 4 x 1,5 V AA (supplied) 4x 1,2 V NiMH-Akku or via USB port
64 products found
Sort by:
Recommended