More search options
64 products found
  • Hanna Instruments HI-93703 Portable Turbidity Meter

    This microprocessor based turbidity meter delivers laboratory grade accuracy for field or factory use. 

    Specifications

    Range
    0.00 to 50.00 FTU;
    50 to 1000 FTU
    Resolution
    0.01 FTU (0.00 to 50.00 FTU);
    1 FTU (50 to 1000 FTU)
    Accuracy
    ±0.5 FTU or ±5% of reading (whichever is greater)
    Calibration
    3 points (0 FTU, 10 FTU and 500 FTU)
    Light Source
    infrared LED
    Light Life
    Life of the instrument
    Light Detection
    Silicon Photocell
    Battery Type / Life
    4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
    automatic shut-off after 5 minutes of non-use
    Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions
    220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
    Weight
    510 g (1.1 lb.)
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703C Portable Turbidity Meter Kit

    This microprocessor based turbidity meter delivers laboratory grade accuracy for field or factory use. Supplied with a complete calibration and maintenance kit in a case.

    Water resistant, easy to hold and with a simple three-point calibration process, it is ideal for water testing and has proved highly popular across the UK.

    Specifications

    Range
    0.00 to 50.00 FTU;
    50 to 1000 FTU
    Resolution
    0.01 FTU (0.00 to 50.00 FTU);
    1 FTU (50 to 1000 FTU)
    Accuracy
    ±0.5 FTU or ±5% of reading (whichever is greater)
    Calibration
    3 points (0 FTU, 10 FTU and 500 FTU)
    Light Source
    infrared LED
    Light Life
    Life of the instrument
    Light Detection
    Silicon Photocell
    Battery Type / Life
    4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
    automatic shut-off after 5 minutes of non-use
    Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions
    220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
    Weight
    510 g (1.1 lb.)
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93414-11 Calibration Set for Turbidity Meters

    The HI-93414-11 Free and Total Chlorine CAL Check™ Standards provide a simple solution to calibrating and validating compatible benchtop and portable photometers.

    This high quality set of standards is manufactured in our state-of-the-art facility and comes supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying compatible free and total chlorine photometers

    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93124-03 Haze Turbidity Meter Calibration Kit

    The HI-93124-03 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.



    Price Upon Application Or Discontinued
  • WTW 600325 Turb 430 T, Portable Turbidity Meter for Nephelometric Measurement

    Specifications

    MethodNephelometrisch (90° Straylight)
    Light SourceTungsten
    acc. to Standard MethodUS-EPA 180.1
    Measuring Range0-1100 FNU/NTU
    Resolution0,01 for 0,00 -9,99
     0,1 for 10 – 99,90
     1 for 100 - 1100
    Accuracy0.01 NTU or +/- 2% of meas.value
    Reproducability< 0.5%
    CalibrationAutomatic, 3 Point
    Calibration Protocolyes
    Calibration Intervalyes
    Data Storage1000 values
    Response TimeCa. 3 s
    Cuvette28 x 60 mm, 20 ml Sample Volume
    Ident Numberyes
    Firmware-Updateyes
    InterfaceRS 232, USB via Adapter (optional)
    Operation Temp.0... +50°C
    Power Supply4 Mignon (AA) > 3000 Measurements
    Rech.Batt.optional
    Data Management GLP compliantoptional PC software LSdata
    LabStation+ PC-Software LSdataoptional as small benchtop solution
    • £1584.81
  • Hanna Instruments HI-93102 Multi Range Portable Turbidity Meter for Water Analysis

    Measures Turbidity, free and total Chlorine, pH, Bromine, Iron, Iodine, and Cyanuric acid the most important parameters needed for water analysis, especially in drinking water. 

    Specifications

    Range:

     Turbidity
    0.00 to 9.99 NTU / 0.00 to 50.0 NTU
     Bromine
    0.00 to 8.00 mg/L (ppm)
     Free Cl2
    0.00 to 2.50 mg/L (ppm)
     Total Cl2
    0.00 to 3.50 mg/L (ppm)
     CYS
    0 to 80 mg/L (ppm)
     Iodine
    0.0 to 12.5 mg/L (ppm)
     Iron LR
    0.00 to 1.00 mg/L (ppm)
     pH
    6.5 to 8.5 pH
    Resolution:

     Turbidity
    0.01 and 0.1 NTU
     Bromine
    0.01 mg/L (ppm)
     Free and Total Cl2
    0.01 mg/L (ppm)
     CYS
    1 mg/L (ppm)
     Iodine
    0.1 mg/L (ppm)
     Iron LR
    0.01 mg/L (ppm)
     pH
    0.1 pH
    Accuracy @25°C:

     Turbidity
    ±0.5 NTU or ±5% of reading (whichever is greater)
     Bromine
    ±0.08 mg/L (ppm) ±3% of reading
     Free and Total Cl2
    ±0.03 mg/L (ppm) ±3% of reading
     CYS
    ±1 mg/L (ppm) ±15% of reading
     Iodine
    ±0.1 mg/L (ppm) ±5% of reading
     pH
    ±0.1 pH
    Calibration
    two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended)
    Light Source
    pure green LED
    Light Detector
    silicon photocell
    Battery Type / Life
    1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes
    Environment
    0 to 50°C (32 to 122°F); RH max 95% (non condensing)
    Dimensions / Weight
    220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.)
    • £1187.00
  • Hanna Instruments HI-98713 ISO Portable Turbidity meter with Fast Tracker Technology

    HI-98713 is a high accuracy ISO compliant portable turbidity meter that benefits from Hanna’s years of experience as manufacturer of analytical instruments.

    The HI-98713 meets and exceeds the requirements of the ISO 7027 for water quality. The instrument is specially designed for water quality measurements, providing a reliable and accurate reading on low turbidity values. Ratio method with 90° and 180° light detector for accurate measurements


    Specifications

    Range
    0.00 to 9.99 FTU
    10.0 to 99.9 FTU
    100 to 1000 FTU
    Range Selection
    Automatically
    Resolution
    0.01 FTU from 0.00 to 9.99 FTU
    0.1 FTU from 10.0 to 99.9 FTU
    1 FTU from 100 to 1000 FTU
    Accuracy
    ±2% of reading plus 0.1 FTU
    Repeatability
    ±1% of reading or 0.01 FTU, whichever is greater
    Stray Light
    < 0.1 FTU
    Typical EMC Deviation
    ±0.05 FTU
    Light Source
    860 nm infrared LED
    IR Detector
    Silicon Photocell
    Method
    Adaptation of ISO 7027, ratio method with 90° and 180° detector.
    Display
    60 x 90 mm LCD with backlight
    Standards
    < 0.1, 15, 100 and 750 FTU
    Calibration
    Two, three or four point calibration
    Logging Memory
    200 records
    Serial Interface
    RS232 and USB 1.1
    Environment
    0 to 50°C (32 to 122°F); max 95% RH non-condensing
    Power Supply
    4 x 1.5V AA alkaline batteries or AC adapter
    Auto Shut-off
    After 15 minutes of non-use
    Dimensions
    224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
    Weight
    512 g (18 oz.)
    Price Upon Application Or Discontinued
  • WTW 600325 Turb® 430 T / SET, Portable Turbidity Meter for Nephelometric Measurement

    Specifications

    MethodNephelometrisch (90° Straylight)
    Light SourceTungsten
    acc. to Standard MethodUS-EPA 180.1
    Measuring Range0-1100 FNU/NTU
    Resolution0,01 for 0,00 -9,99
     0,1 for 10 – 99,90
     1 for 100 - 1100
    Accuracy0.01 NTU or +/- 2% of meas.value
    Reproducability< 0.5%
    CalibrationAutomatic, 3 Point
    Calibration Protocolyes
    Calibration Intervalyes
    Data Storage1000 values
    Response TimeCa. 3 s
    Cuvette28 x 60 mm, 20 ml Sample Volume
    Ident Numberyes
    Firmware-Updateyes
    InterfaceRS 232, USB via Adapter (optional)
    Operation Temp.0... +50°C
    Power Supply4 Mignon (AA) > 3000 Measurements
    Rech.Batt.optional
    Data Management GLP compliantoptional PC software LSdata
    LabStation+ PC-Software LSdataoptional as small benchtop solution
    • £1917.20
  • WTW 600321 Turb 430 IR/SET, Portable Turbidity Meter Set for Nephelometric Measurement

    Specifications

    Light sourceLED
    pH measurementyes
    Turbidity measurementyes
    Calibration interval/recordyes
    Cal. adjustment for selected programsno
    Special methods with pH and Temp.yes
    User-defined progr. via LSdata Software100
    Data storage1000
    Setsavailable
    Rechargeable batteries w. universal plugoptional
    Methods/programsca. 200
    Cells / Cuvettes: round16 mm ( H:91-104 mm); 28 mm
    Ident numberyes
    InterfaceRS232
    PC-Connectionyes
    Method-update via Internetyes
    Firmware-update via Internetyes
    LabStation for lab use incl. rechargeable battery + PC Software LSdataoptional
    LSdata Stand alone optionaloptional
    CertificatesCE/ETLus/cETL
    Waterproof housingIP 67
    • £1790.41
  • Hanna Instruments HI-88703-02 Bench Top Turbidity Meter EPA Compliant, Complete with cuvettes


    PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet.Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-88713-02 High Accuracy Bench Top Turbidity Meter, Complete with cuvettes

    Mains powered - All mains operated equipment is compatible with UK AC voltage and frequency – 230V, 50Hz.PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software directly from equipment via a USB port or a RS232 cable outlet.
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703-11 Portable ISO Compliant Turbidity Meter with Data Logging and PC Connectivity

    The HI-93703-11 is a high accuracy benchtop turbidity meter used to determine the turbidity of water and wastewater with high precision in the field as well as in the laboratory. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards used for calibration and performance verification. The HI-93703-11 meets and exceeds the requirements of the ISO 7027 Method for turbidimetric measurements. Additionally, this meter contains a real-time clock and the capabilities to log measurements and transfer them to a PC using the HI-92000 software.

    • Auto shut-off
    • Positive-locking cuvette system ensures cuvette is firmly placed in the cell
    • Logging and real time clock

    Specifications

    Turbidity Range
    0.00 to 50.00;
    50 to 1000
    Resolution
    0.01 FTU (0.00 to 50.00 FTU);
    1 FTU (50 to 1000 FTU)
    Accuracy
    ±0.5 FTU or ±5% of reading (whichever is greater)
    Calibration
    3 points (0 FTU, 10 FTU and 500 FTU)
    Light Source
    infrared LED
    Light Life
    Life of the instrument
    Light Detection
    Silicon Photocell
    Battery Type / Life
    4 x 1.5V AA / approx. 60 hours of continuous use or 900 measurements;
    automatic shut-off after 5 minutes of non-use
    Environment
    0 to 50°C (32 to 122°F); RH max 95% non-condensing
    Dimensions
    220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
    Weight
    510 g (1.1 lb.)
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-83749-20 Bentocheck solution, 100ml, for use with the HI-83749-02 Turbidity meter

    HI-83749-20 Bentocheck Solution is used to establish if bentonite fining agent is needed to stabilise wine. The solution is used with the HI-83749-02 Portable Turbidity and Bentocheck Meter which is designed to determine turbidity levels and protein stability in wine.


    Specifications

    Reagent Code
    Description
    HI-83749-20
    Bentocheck, 100ml
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-98703 Precision Turbidity Portable Meter

    The HI-98703 Precision Turbidity Portable Meter is specially designed for water quality measurements, providing reliable and accurate readings in the low turbidity range. 

    Specifications

    Range
    0.00 to 9.99 NTU
    10.0 to 99.9 NTU
    100 to 1000 NTU
    Range Selection
    Automatic
    Resolution
    0.01 NTU from 0.00 to 9.99 NTU
    0.1 NTU from 10.0 to 99.9 NTU
    1 NTU from 100 to 1000 NTU
    Accuracy
    ±2% of reading plus 0.02 NTU
    Repeatibility
    ±1% of reading or 0.02 NTU, whichever is greater
    Stray Light
    < 0.02 NTU
    Light Source
    tungsten filament lamp
    Light Detector
    Silicon Photocell
    Method
    Ratio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
    Standards
    < 0.1, 15, 100 and 750 FTU
    Calibration
    Two, three or four point calibration
    Logging Memory
    200 records
    Serial Interface
    RS232 and USB
    Environment
    0 to 50°C (32 to 122°F); max 95% RH non-condensing
    Power Supply
    4 x 1.5V AA alkaline batteries or AC adapter
    Auto Shut-off
    After 15 minutes of non-use
    Dimensions
    224 x 87 x 77 mm (8.8 x 3.4 x 3.0")
    Weight
    512 g (18 oz.)
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-83414-02 Turbidity and Free and Total Chlorine Meter

    The HI-83414 is a multiparameter instrument that measures the most important parameters in drinking water – turbidity and chlorine.

    Specifications

    Turbidity Range – non-ratio mode   0.00 to 9.99 NTU
    10.0 to 40.0 NTU
    0.0 to 99.9 NTU
    100 to 268 Nephelos
    0.0 to 9.80 EBC
    Turbidity resolution – non-ratio mode   0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC
    Turbidity Range – ratio mode   0.00 to 9.99 NTU
    10.0 to 99.9 NTU
    100 to 4000 NTU
    0.0 to 99.9 NTU
    100 to 26800 Nephelos
    0.00 to 9.99 NTU
    10.0 to 99.9
    100 to 980 EBC
    Turbidity resolution – ratio mode   0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC
    Free and Total Chlorine Range   0.00 to 5.00 mg/L
    Range Selection   Automatic
    Free and Total Chlorine Resolution   0.01 mg/L from 0.00 to 3.50mg/L
    0.10 above 3.50 mg/L
    Turbidity Accuracy   ±2% of reading plus 0.02 NTU; ±5% of reading above 1000 NTU
    Free and Total Chlorine Accuracy   ±0.02 mg/L @ 1.00 mg/L
    Repeatability   ±1% of reading or 0.02 NTU, whichever is greater
    Stray Light   < 0.02 NTU
    Light Source   tungsten filament lamp
    Light Detector   Silicon Photocell
    Turbidity Method   Ratio Nephelometric Method (90° and 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B
    Free and Total Chlorine Method   Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G
    Turbidity Standards   < 0.1, 15, 100, 750 & 2000 NTU
    Free and Total Chlorine Standards   1.00 mg/L free chlorine, 1.00 mg/L total chlorine
    Turbidity Calibration   Two, three, four or five point calibration
    Free and Total Chlorine Calibration   one-point calibration
    Logging Memory   200 records
    Serial Interface   USB
    Environment   up to 50°C (32 to 122°F); max 95% RH non-condensing
    Power Supply   230 Vac adapter
    Auto Shut-off   After 15 minutes of non-use
    Dimensions   230 x 200 x 145 mm
    Weight   2.5kg
    Order Information   HI-83414-02 is supplied with sample cuvettes and caps (5), calibration cuvettes for turbidity (HI-88703-11) and colorimeter (HI-93414-11), silicone oil (HI-98703-58), cuvette wiping cloth, scissors, power cord and instruction manual.
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93414-02 EPA Compliant Turbidity and Free & Total Chlorine Meter

    The HI-93414 is a multiparameter instrument that measures the most important parameters in drinking water: turbidity and chlorine. The instrument is based on a state-of-the-art optical system which provides accurate results by minimising stray light and colour interferences.

    The colorimeter portion of the meter uses a 525nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine

    Specifications

    Turbidity Range
    0.00 to 9.99 NTU
    10.0 to 99.9 NTU
    100 to 1000 NTU
    Free and Total Chlorine Range
    0.00 to 5.00 mg/L
    Range Selection
    Automatic
    Turbidity Resolution
    0.01 NTU from 0.00 to 9.99 NTU
    0.1 NTU from 10.0 to 99.9 NTU
    1 NTU from 100 to 1000 NTU
    Free and Total Chlorine Resolution
    0.01 mg/L from 0.00 to 3.50mg/L
    0.10 above 3.50 mg/L
    Turbidity Accuracy
    ±2% of reading plus 0.02 NTU
    Free and Total Chlorine Accuracy
    ±0.03 mg/L ±3% of reading
    Repeatability
    ±1% of reading or 0.02 NTU, whichever is greater
    Stray Light
    < 0.02 NTU
    Light Source
    tungsten filament lamp
    Light Detector
    Silicon Photocell
    Turbidity Method
    Ratio Nephelometric Method, ratio of scattered and transmitted light; Adaptation of the USEPA Method 180.1 and Standard Method 2130 B
    Free and Total Chlorine Method
    Adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample
    Turbidity Standards
    < 0.1, 15, 100 and 750 FTU
    Free and Total Chlorine Standards
    1 mg/L free chlorine, 1 mg/L total chlorine
    Turbidity Calibration
    Two, three or four point calibration
    Free and Total Chlorine Calibration
    one-point calibration
    Logging Memory
    200 records
    Serial Interface
    RS232 and USB
    Environment
    up to 50°C (32 to 122°F); max 95% RH non-condensing
    Power Supply
    4 x 1.5V AA alkaline batteries or AC adapter
    Auto Shut-off
    After 15 minutes of non-use
    Dimensions
    224 x 87 x 77 mm (8.8 x 3.4 x 3.0")
    Weight
    512 g (18 oz.)
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-98703-11 Turbidity Calibration Set for HI-98703

    Turbidity calibration standards <0.1, 15, 100 and 750 NTU.


    Price Upon Application Or Discontinued
  • Hanna Instruments HI-98713-11 Turbidity Calibration Set for HI-98713

    The HI-98713-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.

    Supplied with Certificate of Analysis

    • Product code
    • Lot number
    • Expiry date
    • Standard value @ 25°C
    • Reference meter NIST traceable

    Provided storage containers

    • Light tight
    • Protects from accidental breakage
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93124-2 Turbidity Standard Solution 125 EBC

    The HI-93124-2 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.

    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93102-0 Turbidity Standard 0 NTU

    The HI-93102-0 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.

    Specifications

    Description
    AMCO-AEPA-1 Calibration Solution at 0 NTU
    Bottle
    30 mL
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-88713-11 Calibration set for HI-88713-02

    Price Upon Application Or Discontinued
  • WTW 600311 Turb® 355 IR Portable Turbidimeter with LED, Nephelometric Method

    Specifications

    MethodNephelometric (90° Straylight)
    Light SourceIR LED
    acc. to Standard MethodDIN 27027 / ISO 7027
    Measuring Range0-1100 FNU+NTU
    Resolution0,01 for 1 -9,99
     0,1 for 10 – 99,90
     1 for 100 - 1100
    Accuracy+/- 2% of value or +/-0.01
     last decimal pos.for 1-500 NTU
     +/- 3% of meas. Value from 500-1100 NTU
    Reproducibility+/- 1% of meas.val. or +/-0.01 NTU
    CalibrationAutomatic 1-3 Point
    Calibration Protocolno
    Calibration Intervalno
    Data Storageno
    Response TimeCa. 14 s
    Cuvette25 x 45 mm, 15 ml sample volume
    Ident Numberno
    Firmware-Updateno
    Interfaceno
    Operation Temp.0... +50°C
    Power Supply4 Mignon (AAA) > 3000 Measurements
    Rech.Batt.no
    • £1475.16
  • WTW 600312 Turb® 355 T Portable Turbidimeter with Tungsten Lamp

    Specifications

    MethodNephelometric (90° Straylight)
    Light SourceTungsten
    acc. to Standard MethodUS-EPA 180.1
    Measuring Range0-1100 FNU+NTU
    Resolution0,01 for 1 -9,99
     0,1 for 10 – 99,90
     1 for 100 - 1100
    Accuracy+/- 2% of value or +/-0.01
     last decimal pos.for 1-500 NTU
     +/- 3% of meas. Value from 500-1100 NTU
    Reproducibility+/- 1% of meas.val. or +/-0.01 NTU
    CalibrationAutomatic 1-3 Point
    Calibration Protocolno
    Calibration Intervalno
    Data Storageno
    Response TimeCa. 14 s
    Cuvette25 x 45 mm, 15 ml sample volume
    Ident Numberno
    Firmware-Updateno
    Interfaceno
    Operation Temp.0... +50°C
    Power Supply4 Mignon (AAA) > 3000 Measurements
    Rech.Batt.no
    • £1554.83
  • Hanna Instruments HI-83749-11 Turbidity Calibration Kit for use with HI-83749-02

    The HI-83749-11 Turbidity Calibration Standards provide a simple solution to calibrating and validating the HI-83749 Portable Turbidity and Bentonite check Meter. Hanna turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.

    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703-50 Cuvette Cleaning Solution, 230ml

    HI-93703-50 is an alcohol based cleaning solution for cuvettes/vials used in photometers and turbidity meters. This anti-static solution ensures the glass cuvette used for colorimetric and turbidimetric measurements remains clean and free from imperfections.


    Specifications

    Size
    230ml
    Package
    Bottle
    Quantity
    1
    Certificate of Analysis
    No
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93124-0 Standard Solution 0 EBC

    The HI-93124-0 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.

    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93124-1 Standard Solution 2.5 EBC

    The HI-93124-1 EBC Haze Meter 2.5 EBC Calibration Standard provides a simple solution to calibrating and validating the HI-93124 turbidity meter that has a 0 to 10.00 and 10 to 250 EBC range. Hanna’s turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter.

    Specifications

    Package
    Standard solution: 2.5 EBC (30ml bottle)
    Quantity
    1 bottle
    Applications
    Beer Analysis, beverage
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703-05 AMCO-AEPA-1 Calibration Solution at 500 FTU

    AMCO-EPA solution @ 500 FTU (30 mL)

    The HI-93703-05 Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.

    Specifications

    Description
    AMCO-AEPA-1 Calibration Solution at 500 FTU
    Bottle
    30 mL
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703-10 AMCO-AEPA-1 Calibration Solution at 10 FTU

    AMCO-EPA solution @ 10 FTU (30 mL)

    The HI-93703-10 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.


    Specifications

    Description
    AMCO-AEPA-1 Calibration Solution at 10 FTU
    Bottle
    30 mL
    Price Upon Application Or Discontinued
  • Hanna Instruments HI-93703-0 AMCO-AEPA-1 Calibration Solution at 0 FTU

    AMCO-EPA solution @ 0 FTU (30 mL).

    The HI-93703-0 Turbidity Calibration Standards provide a simple solution to calibrating and validating turbidity meters that have a 0 to 1000 FNU range. HANNA turbidity calibration standards are prepared from NIST traceable primary standard reference materials and come supplied with a certificate of analysis. The certificate of analysis provides the lot number, reference values, and expiry date for traceability when certifying the appropriate turbidity meter. Suitable for Aquaculture & Aquariums, Education, Environmental, Laboratory, Water Conditioning, Drinking Water & Wastewater Treatment industries.

    Specifications

    Description
    AMCO-AEPA-1 Calibration Solution at 0 FTU
    Bottle
    30 mL
    Price Upon Application Or Discontinued
  • Grant Bio DEN-1 & DEN-1B McFarland Tube Densitometer
    • 20% off
    • £468.00
  • WTW 2FD57V Multi 3630 IDS SET KS2 Multi-Parameter Portable Meter MultiLine

    Measure three parameters simultaneously –pH, ORP, dissolved oxygen, conductivity and/or turbidity with the digital pocket meter Multi 3630 IDS

    - Wireless ready
    - Measure, display and document three parameters plus secondary information
    - Digital sensor detection

    Price Upon Application Or Discontinued
  • WTW 2FD570 Multi-Parameter Portable Meter MultiLine® Multi 3630 IDS

    Technical Data

    Measuring rangesDepending on the respective IDS sensor
    DisplayLCD color graphic, backlit
    Data memorymanual 500 / 10000 automatic
    Measuring channels3
    Protection classIP 67
    InterfacesMini-USB-B, USB-A
    Power supplyWide range power supply, 4x 1.2 V NiMH battery or via Mini USB-B
    Price Upon Application Or Discontinued
  • WTW 2FD57F Multi-Parameter Portable Meter MultiLine® Multi 3630 IDS SET F contains SenTix® 940, FDO® 925, TetraCon® 925


    Measure three parameters simultaneously – pH, ORP, dissolved oxygen, conductivity and/or turbidity with the digital pocket meter Multi 3630 IDS

    • Wireless ready
    • Measure, display and document three parameters plus secondary information
    • Digital sensor detection
    • Three galvanically isolated sensor inputs


    Technical Data

    Measuring ranges
    Depending on the respective IDS sensor
    Display
    LCD color graphic, backlit
    Data memory
    manual 500 / 10000 automatic
    Measuring channels
    3
    Protection class
    IP 67
    Interfaces
    Mini-USB-B, USB-A
    Power supply
    Wide range power supply, 4x 1.2 V NiMH battery or via Mini USB-B


    Full Description

    Multi 3630 IDS SET F- Professional wireless ready digital multi meter for portable field measurements, with three channel input, colour graphic display inc datalogger and USB interfaces. Single instrument in case with buffer 4 and 7, 3 mol/l KCL conductivity standard, short instruction manual, CD-ROM, rechargeable batteries driver software for USB, cable and universal power supply. Set includes meter in field case with IDS sensors: digital pH electrodes SenTix 940, digital conductivity cell TetraCon 925, optical DO probe FDO 925 and QSC Kit

    Price Upon Application Or Discontinued
  • WTW 600700 VisoTurb 900-P IDS Turbidity Sensors with Universal Plug Head

    Digital turbidity sensor for the IDS system

    Digital IDS turbidity measurement with a practical turbidity sensor for mobile applications in surface waters and process - the VisoTurb® 900-P

    - Convenient turbidity sensor for MultiLine® IDS for measurements on site
    - Easy 2 or 3 point calibration
    - Suitable for multi-parameter measurements

    Price Upon Application Or Discontinued
  • WTW 2FD353 Multi 3510 IDS SET 3 Multi-Parameter Portable Meter

    Measuring rangeMeasuring range of the IDS sensor
    DisplayLCD graphic, backlit
    Memorymanual 500 / 4500 automatic
    Measurement channel1
    Protection classIP 67
    Power supply4 x 1,5 V AA (supplied) 4x 1,2 V NiMH-Akku or via USB port
    Price Upon Application Or Discontinued
  • WTW 2FD350 Multi 3510 IDS Multi-Parameter Portable Meter MultiLine

    Measuring rangeMeasuring range of the IDS sensor
    DisplayLCD graphic, backlit
    Memorymanual 500 / 4500 automatic
    Measurement channel1
    Protection classIP 67
    Power supply4 x 1,5 V AA (supplied) 4x 1,2 V NiMH-Akku or via USB port
    Price Upon Application Or Discontinued
Items: 140 of 64