Hanna Instruments HI-93102 Multi Range Portable Turbidity Meter for Water Analysis
Measures Turbidity, free and total Chlorine, pH, Bromine, Iron, Iodine, and Cyanuric acid the most important parameters needed for water analysis, especially in drinking water.
Specifications
Range: | ||
Turbidity | 0.00 to 9.99 NTU / 0.00 to 50.0 NTU | |
Bromine | 0.00 to 8.00 mg/L (ppm) | |
Free Cl2 | 0.00 to 2.50 mg/L (ppm) | |
Total Cl2 | 0.00 to 3.50 mg/L (ppm) | |
CYS | 0 to 80 mg/L (ppm) | |
Iodine | 0.0 to 12.5 mg/L (ppm) | |
Iron LR | 0.00 to 1.00 mg/L (ppm) | |
pH | 6.5 to 8.5 pH | |
Resolution: | ||
Turbidity | 0.01 and 0.1 NTU | |
Bromine | 0.01 mg/L (ppm) | |
Free and Total Cl2 | 0.01 mg/L (ppm) | |
CYS | 1 mg/L (ppm) | |
Iodine | 0.1 mg/L (ppm) | |
Iron LR | 0.01 mg/L (ppm) | |
pH | 0.1 pH | |
Accuracy @25°C: | ||
Turbidity | ±0.5 NTU or ±5% of reading (whichever is greater) | |
Bromine | ±0.08 mg/L (ppm) ±3% of reading | |
Free and Total Cl2 | ±0.03 mg/L (ppm) ±3% of reading | |
CYS | ±1 mg/L (ppm) ±15% of reading | |
Iodine | ±0.1 mg/L (ppm) ±5% of reading | |
pH | ±0.1 pH | |
Calibration | two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) | |
Light Source | pure green LED | |
Light Detector | silicon photocell | |
Battery Type / Life | 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% (non condensing) | |
Dimensions / Weight | 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) |
The most important parameters needed for water analysis can all be measured by using the HI-93102.
Delivering laboratory grade accuracy, this all in one instrument allows operators to measure turbidity, pH, total and free chlorine, bromine, iodine, iron and cyanuric acid quickly and easily.
Designed for rigorous testing conditions where speed and precision are of utmost importance, it is the ideal meter for measuring drinking water and similar high definition applications.
Key features
- Measurement cuvette and cap supplied as standard - spares available as optional
- Log and retrieve up to 25 different samples
- Clear LCD gives readings across all parameters
- Robust waterproof casing
- Rubberised keyboard with responsive buttons
- Calibration options allow users to either select the factory pre-programmed setting or choose their own
Main benefits
- Sophisticated microprocessor ensures measurements are delivered with speed, precision and repeatability
- Capacity to log and retrieve up to 25 different samples including time and date of measurement
- Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU or to select factory pre-programmed setting
- Use of high end technology delivers optimum accuracy and quality of results in a portable hand-held unit that weighs little more than 500 grams
Supplied with
- Measurement cuvette and cap
- Batteries
- Instructions
Water Resistant – Can withstand temporary exposure to water, but should not be submerged or washed under running water.
Battery powered – Allows use away from a power source. Batteries are included with all battery operated products.
urbidity | 0.00 to 9.99 NTU / 0.00 to 50.0 NTU | |
Bromine | 0.00 to 8.00 mg/L (ppm) | |
Free Cl2 | 0.00 to 2.50 mg/L (ppm) | |
Total Cl2 | 0.00 to 3.50 mg/L (ppm) | |
CYS | 0 to 80 mg/L (ppm) | |
Iodine | 0.0 to 12.5 mg/L (ppm) | |
Iron LR | 0.00 to 1.00 mg/L (ppm) | |
pH | 6.5 to 8.5 pH | |
Resolution: | ||
Turbidity | 0.01 and 0.1 NTU | |
Bromine | 0.01 mg/L (ppm) | |
Free and Total Cl2 | 0.01 mg/L (ppm) | |
CYS | 1 mg/L (ppm) | |
Iodine | 0.1 mg/L (ppm) | |
Iron LR | 0.01 mg/L (ppm) | |
pH | 0.1 pH | |
Accuracy @25°C: | ||
Turbidity | ±0.5 NTU or ±5% of reading (whichever is greater) | |
Bromine | ±0.08 mg/L (ppm) ±3% of reading | |
Free and Total Cl2 | ±0.03 mg/L (ppm) ±3% of reading | |
CYS | ±1 mg/L (ppm) ±15% of reading | |
Iodine | ±0.1 mg/L (ppm) ±5% of reading | |
pH | ±0.1 pH | |
Calibration | two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) | |
Light Source | pure green LED | |
Light Detector | silicon photocell | |
Battery Type / Life | 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes | |
Environment | 0 to 50°C (32 to 122°F); RH max 95% (non condensing) | |
Dimensions / Weight | 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) |