Hanna Instruments HI-88703-02 Bench Top Turbidity Meter EPA Compliant, Complete with cuvettes
he HI-88703-02 turbidity bench top meter is specially designed for water quality measurements, providing reliable and accurate readings on low turbidity ranges.
This instrument has an EPA compliance reading mode which rounds the reading to meet EPA reporting requirements. Depending on the measured sample and needed accuracy, normal, continuous or signal averaging measurement can be selected.
A two, three, four or five-point calibration can be performed. When user prepared standards are used, calibration points can be modified. The HI-88703-02 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points, time and date can be checked. Up to 200 measurements can be stored in internal memory. Data can be transferred to a PC via optional HI 920013 USB cable and HI 92000 Windows® compatible software.
Key features
- Two measuring ranges: Ratio turbidity, non-ratio turbidity
- GLP features
- Two, three, four or five point turbidity calibration
- USB PC connectivity
- Log up to 200 measurements
- Contextual help and tutorial mode
Order information
The HI-88703-02 is supplied with sample cuvettes and caps (5), calibration cuvettes, silicone oil (HI-93703-58), tissue for wiping cuvettes, power cord and instruction manual.
Range - non ratio mode | 0.00 to 9.99; 10.0 to 40.0 NTU 0.0 to 99.9; 100 to 268 Nephelos 0.00 to 9.80 EBC | |
Resolution - non ratio mode | 0.01; 0.1 NTU 0.1; 1 Nephelos 0.01 EBC | |
Range - ratio mode | 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU 0.0 to 99.9; 100 to 26800 Nephelos 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC | |
Resolution - ratio mode | 0.01; 0.1; 1 NTU 0.1; 1 Nephelos 0.01; 0.1, 1 EBC | |
Range Selection | Automatically | |
Accuracy | ±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC) ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC) | |
Repeatibility | ±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater | |
Stray Light | < 0.02 NTU (0.15 Nephelos; 0.01 EBC) | |
Light Detection | Silicon Photocell | |
Method | Nephelometric method (90°) or Ratio Nephelometric Method (90° & 180°), Adaptation of the USEPA Method 108.1 and Standard Method 2130 B. | |
Measuring mode | Normal, Average, Continuous. | |
Turbidity Standards | <0.1, 15, 100, 750 and 2000 NTU | |
Calibration | Two, three, four or five-point calibration | |
Light Source | Tungsten filament lamp | |
Lamp life | greater than 100,000 readings | |
Display | 40 x 70mm graphic LCD (64x128 pixels) with backlight | |
Logging Memory | 200 records | |
Serial Interface | USB | |
Environment | 0°C (32°F) to 50°C (122°F); max 95% RH non-condensing | |
Power Supply | 230 V/50 Hz or 115 V/60 Hz 20 W | |
Auto Shut-off | After 15 minutes of non-use | |
Dimensions | 230 x 200 x 145 mm (9 x 7.9 x 5.7”) L x W x H | |
Weight | 2.5 Kg (88 oz.) |