WTW 1P21 CR 2200 Thermoreactors for Chemical Oxygen Demand, 1 x 12 Maximum Number of Samples
Specification
Reactor type Dry temperature control device with safety cover Cell shafts 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting fixed time settings acc. to standard method digestion programs Temperature setting 100 °C, 120 °C, 148 °C, 150 °C acc. to program Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 -
WTW 1P21 CR 3200 Thermoreactors for Chemical Oxygen Demand, 2 x 12 Maximum Number of Samples , Same Program
Specification
Reactor type Dry temperature control device with safety cover Cell shafts 2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting program settings or user-defined programs up to 180 min Temperature setting stored program, user-defined settings from room temperature up to 170°C Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 -
WTW 1P23 CR 4200 Thermoreactors for Chemical Oxygen Demand, 2 x 12 Maximum Number of Samples , Different Program
Specification
Reactor type Dry temperature control device with safety cover Cell shafts 2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting program settings or user-defined programs up to 180 min Temperature setting stored program, user-defined settings from room temperature up to 170°C Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 -
VELP Scientifica CA0091666 ECO 8 only - Test tube for sample decomposition Ø 22mm
NS 19/26 cone with glass cap for sludge analysis
-
Mettler Toledo 30094121 InMotion™ Flex Autosampler
Specifications - InMotion™ Flex Autosampler
Material Number(s) 30094121 Through Put 25 mL vials 50 80 mL beakers 27 100 mL beakers 18 180 mL beakers 15 250 mL beakers 11 Connectivity SmartSample™ Kit Yes Barcode Reader Yes Water Bath Rack Yes (100 mL only) CoverUp™ Lid Handling Yes (not 25 or 250 mL) Chemical Oxygen Demand Kit Yes Karl Fischer Direct Kit Yes (100 mL only) Magnetic Stirrer Yes 2nd Tower Yes (not with 25 mL rack) Racks Diameter (cm) 42 Material Polypropylene Material Numbers Autosampler InMotion Flex 100mL (Flex Base and 100 mL Rack Kit Bundle) 30094120 Base InMotion Flex (Rack Kit sold separately) 30094121 Rack Kit InMotion Flex 25mL 30094124 Rack Kit InMotion Flex 80mL 30094125 Rack Kit InMotion Flex 100mL 30094126 Rack Kit InMotion Flex 180mL 30094127 Rack Kit InMotion Flex 250mL 30094128 Rack Kit InMotion Flex Waterbath 100mL 30094139 -
WTW 1P22- CR 3200 Thermoreactor Digestions of 24 Round Cells
Reactor type Dry temperature control device with safety cover Cell shafts 2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting program settings or user-defined programs up to 180 min Temperature setting stored program, user-defined settings from room temperature up to 170°C Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 -
WTW 1P21-3 CR 2200 Thermoreactor for Easy Digestion of Standard Parameters
Reactor type Dry temperature control device with safety cover Cell shafts 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting fixed time settings acc. to standard method digestion programs Temperature setting 100 °C, 120 °C, 148 °C, 150 °C acc. to program Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 -
WTW 1P23-3 CR 4200 Thermoreactor
Reactor type Dry temperature control device with safety cover Cell shafts 2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm Reaction time setting program settings or user-defined programs up to 180 min Temperature setting stored program, user-defined settings from room temperature up to 170°C Controlling accuracy ± 1 °C ± 1 digit Temperature stability ± 0.5 K Overtemperature protection 190 °C ± 5 °C Dimensions D x W x H: 312 x 255 x 185 mm Weight: 4 kg Output unidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC Power supply 115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 ATProtection Class IP 20 according to EN 60529 Ambient temperature Operation +5 °C to +40 °C Climatic class 2 according to VDI/VDE 3540 Relative humidity: Yearly mean: < 75 % 30 days /year: 95 % Other days: 85 % Light dew: yes Site altitude: max. 5000 m above sea level EMC EN 61326-1 FCC 47 CFR Part 15 Test certificates cETLus, CE Safety standards EN 61010-1 EN 61010-2-010 UL 61010-1 CAN/CSA C22.2#61010-1 CAN/CSA C22.2#61010-2-010 Digestions with 2x12 round cells at 2 different programs
With CR 4200 two different digestion programs can be performed for 16 mm vials simultaneously in two seperate heating blocks for 12 vials each.
• 8 stored programs for quick operation
• 8 user-defined programs from 25-170°C for high temperature digestion up to 170°C
• AQA/IQC with external temperature sensor -
Hanna HI-83314-02 Multi-parameter Wastewater & Water Photometer with COD and pH meter
One meter can be used for both photometric and pH measurements. HI-83314 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. Ten key water and wastewater quality parameters with 20 different methods.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83314 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. -
Hanna HI-83399 Water and Wastewater Multi-Parameter with COD Photometer & pH Meter
One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.
40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
26 products found
Sort by:
Recommended