More search options
17 products found
  • WTW 1BA300 inoLab® Oxi 7310 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA


    Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food

    • Application-relevant oxygen measurement by three selectable oxygen sensors
    • Precise measurements based on automatic air pressure compensation
    • Documentation of all data via USB interface or optional built-in printer - quick and error-free

     

    Technical Data

    alle values ±1 digit
     
    Concentration
    0.00 … 20.00 mg/l ±0.5 % of value.
    0 … 90 mg/L ±0.5 %
    Saturation
    0.0 … 200.0 % ±0.5 % of value
    0 to 600 % ±0.5 % of value
    Partial pressure
    0 … 200.0 hPa, 0 to 1250 hPa
    Temperature
    -5.0 … 105.0 °C ±0.1 °C


    Full Description

    WTW inoLab® Oxi 7310 Professional dissolved oxygen  meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors

    Price Upon Application Or Discontinued
  • WTW 1BA300P inoLab® Oxi 7310P Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with built-in printer


    Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food

    • Application-relevant oxygen measurement by three selectable oxygen sensors
    • Precise measurements based on automatic air pressure compensation
    • Documentation of all data via USB interface or optional built-in printer - quick and error-free

     

    Technical Data

    alle values ±1 digit
     
    Concentration
    0.00 … 20.00 mg/l ±0.5 % of value.
    0 … 90 mg/L ±0.5 %
    Saturation
    0.0 … 200.0 % ±0.5 % of value
    0 to 600 % ±0.5 % of value
    Partial pressure
    0 … 200.0 hPa, 0 to 1250 hPa
    Temperature
    -5.0 … 105.0 °C ±0.1 °C


    Full Description

    WTW inoLab® Oxi 7310 Professional dissolved oxygen  meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors

    Price Upon Application Or Discontinued
  • Hanna Instruments HI-2400 Bench-Top Dissolved Oxygen Meter measures and records up to 8,000 samples

    PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software (HI-92000), directly from equipment via a USB port or a RS232 cable outlet.

    Replaceable Electrode – No need to replace the whole meter when the electrode needs replacing. Spare and replacement electrodes are available for this product.

    Price Upon Application Or Discontinued
  • WTW 1BA301 inoLab® Oxi 7310 SET 1 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with CellOx® 325 Galvanic oxygen sensor


    Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food

    • Application-relevant oxygen measurement by three selectable oxygen sensors
    • Precise measurements based on automatic air pressure compensation
    • Documentation of all data via USB interface or optional built-in printer - quick and error-free

     

    Technical Data

    alle values ±1 digit
     
    Concentration
    0.00 … 20.00 mg/l ±0.5 % of value.
    0 … 90 mg/L ±0.5 %
    Saturation
    0.0 … 200.0 % ±0.5 % of value
    0 to 600 % ±0.5 % of value
    Partial pressure
    0 … 200.0 hPa, 0 to 1250 hPa
    Temperature
    -5.0 … 105.0 °C ±0.1 °C


    Full Description

    WTW inoLab® Oxi 7310 SET 1 Professional dissolved oxygen  meter, menu controlled, for measurements/documentation according GLP/AQA. Set including galvanic D.O. sensor. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G - input for serial number of sensors

    Price Upon Application Or Discontinued
  • WTW 1BA304 inoLab® Oxi 7310 SET 4 Benchtop Dissolved Oxygen Meter Measurement for measurements/documentation according GLP/AQA with StirrOx® Self-Stirring Dissolved Oxygen Sensor


    Benchtop meter with documentation function for dissolved oxygen – environmental area (BOD), industrial applications such as pharmaceutical research, beverage and food

    • Application-relevant oxygen measurement by three selectable oxygen sensors
    • Precise measurements based on automatic air pressure compensation
    • Documentation of all data via USB interface or optional built-in printer - quick and error-free

     

    Technical Data

    alle values ±1 digit
     
    Concentration
    0.00 … 20.00 mg/l ±0.5 % of value.
    0 … 90 mg/L ±0.5 %
    Saturation
    0.0 … 200.0 % ±0.5 % of value
    0 to 600 % ±0.5 % of value
    Partial pressure
    0 … 200.0 hPa, 0 to 1250 hPa
    Temperature
    -5.0 … 105.0 °C ±0.1 °C


    Full Description

    WTW inoLab® Oxi 7310 SET 4 inoLab¨ Oxi 7310 SET 4  Professional dissolved oxygen  meter, menu controlled, for measurements/documentation according GLP/AQA. Set including galvanic D.O. sensor. - Backlit graphic display - Date, time, ID numbers - For CellOx¨ 325 and StirrOx¨ G

    Price Upon Application Or Discontinued
  • WTW 1FD35C inoLab Multi 9310 SET C Multi Parameter Benchtop Meter for pH, ORP, Dissolved Oxygen and Conductivity

    Specifications

    Measuring channel1 (universal)
    ParameterpH, ORP, dissolved oxygen, conductivity
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD graphic, backlit
    CMC/QSCYes/Yes
    Data memorymanual 500/4500 automatic
    Loggermanual/timer-controlled
    InterfaceMini USB-B
    Printer (optional)Thermal printer, width 58 mm
    Power supplyUniversal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries
    • £1520.56
  • WTW 1FD350 Multi-Parameter Benchtop Meter inoLab® Multi 9310 IDS for pH, ORP, dissolved oxygen and conductivity

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters - Universal application. 

    Price Upon Application Or Discontinued
  • WTW 1FD350P Multi-Parameter Benchtop Meter inoLab® Multi 9310P IDS for pH, ORP, dissolved oxygen and conductivity , with built-in printer

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    ionlab Multi 9310P Digital multi-parameter bench-top for IDS sensors with integrated printer for measurements/documentation according GLP/AQA, with integrated thermal printer. Single channel input. - Back-lit graphic display - Automatic recognition of IDS sensors.

    Price Upon Application Or Discontinued
  • WTW 1FD351 Multi-Parameter Benchtop Meter inoLab® Multi 9310 SET 1 IDS for pH, ORP, dissolved oxygen and conductivity with SenTix® 940-3 Low-maintenance IDS pH gel electrode, 3 m fixed cable

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 SET 1 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Set including IDS sensor. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters

    Price Upon Application Or Discontinued
  • WTW 1FD352 Multi-Parameter Benchtop Meter inoLab® Multi 9310 SET 2 IDS for pH, ORP, dissolved oxygen and conductivity with 103780 SenTix® 980 IDS electrode with 3 mol/l KCl, glass shaft, platinum diaphragm

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 SET 1 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Set including IDS sensor. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters

    Price Upon Application Or Discontinued
  • WTW 1FD570 Multi-Parameter Benchtop Meter inoLab® Multi 9630 IDS or IDS sensors, for measurements/documentation according GLP/AQA


    Technical Data

    Parameter
    pH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels
    3
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD color graphic
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/10000 automatic
    Analog pH/ORP/ISE sensors
    ADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Logger
    manual/timer-controlled
    Interface
    USB A/Mini USB-B
    Printer
    Three preinstalled drivers (description see Operating Instructions)
    Power supply
    Universal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with three inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    • Wireless ready
    • Simultaneous measurement with three independent measuring channels
    • Fatigue proof reading on brilliant color display


    Full Description

    Inolab Multi 9630 IDS - Wirelesss ready professional digital multi-parameter benchtop meter for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen and conductivity. Meter including universal power supply, stand, operation manual, software and USB cable.

    Price Upon Application Or Discontinued
  • WTW 1FD57K Multi-Parameter Benchtop Meter inoLab® Multi 9630 IDS SET K in set with IDS sensors: digital IDS pH electrode SenTix® 980, buffer 4, 7 and 10.01, 3 mol/l KCl, optical IDS D.O. sensor FDO 925, digital IDS cond cell TetraCon® 925, 0.01 mol/l KCl


    Technical Data

    Parameter
    pH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels
    3
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD color graphic
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/10000 automatic
    Analog pH/ORP/ISE sensors
    ADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Logger
    manual/timer-controlled
    Interface
    USB A/Mini USB-B
    Printer
    Three preinstalled drivers (description see Operating Instructions)
    Power supply
    Universal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with three inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    • Wireless ready
    • Simultaneous measurement with three independent measuring channels
    • Fatigue proof reading on brilliant color display


    Full Description

    Inolab Multi 9630 IDS SET K- Wirelesss ready professional digital multi-parameter benchtop meter for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen and conductivity. Meter including universal power supply, stand, operation manual, software and USB cable plus probes optical dissolved oxygen (FDO 925), 4-electrode conductivity cell (TetraCon 925) and pH electrode (SenTix 980)

    Price Upon Application Or Discontinued
  • WTW 1FD354 inoLab Multi 9310 SET 4 Multiparameter Benchtop Meter

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    •Uncompromised measuring accuracy
    •Wireless ready
    •Digital sensor recognition
    •Smart sensor evaluation

    Price Upon Application Or Discontinued
  • WTW 1FD353 inoLab Multi 9310 SET 3 Multiparameter Benchtop Meter

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    •Uncompromised measuring accuracy
    •Wireless ready
    •Digital sensor recognition
    •Smart sensor evaluation

    Price Upon Application Or Discontinued
  • WTW 1FD560 Multi 9620 IDS Multiparameter Benchtop Meter InoLab

    Technical Data

    ParameterpH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels2
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD color graphic
    CMC/QSCYes/Yes
    Data memorymanual 500/10000 automatic
    Analog pH/ORP/ISE sensorsADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Loggermanual/time-controlled
    InterfaceUSB A/Mini USB-B
    PrinterThree pre-installed drivers (description see Operating Instructions)
    Power supplyUniversal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with two inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    •Wireless ready
    •Simultaneous measurement with two independent measuring channels
    •Fatigue proof reading on brilliant color display

    Price Upon Application Or Discontinued
  • WTW 1FD56C Inolab Multi 9620 IDS SET C Multiparameter Benchtop Meter

    ParameterpH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels2
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD color graphic
    CMC/QSCYes/Yes
    Data memorymanual 500/10000 automatic
    Analog pH/ORP/ISE sensorsADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Loggermanual/time-controlled
    InterfaceUSB A/Mini USB-B
    PrinterThree pre-installed drivers (description see Operating Instructions)
    Power supplyUniversal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with two inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    •Wireless ready
    •Simultaneous measurement with two independent measuring channels
    •Fatigue proof reading on brilliant color display

    Price Upon Application Or Discontinued