The Stomacher® 3500 Water Biowasher is designed to process a large volume of filter fibres. This heavy-duty machine is manufactured to industrial standards and is internationally recognised as the standard for sample testing for waterborne parasites.
- Suitable for volume sample sizes from 400ml – 3500ml
- Durable and reliable
- Programmable paddle speeds and run times ensure consistent results
- Easy to use – simple to set up
- Easy to clean
Applications
The Stomacher® 3500 Water Biowasher is designed to process large volumes of filter fibres derived from cartridge filters. Used in testing for waterborne parasites such as cryptosporidium and giardia, the Stomacher® method for preparing these samples is referenced throughout the world.
- Volume sample sizes of 400 – 3500ml
The Stomacher® 3500 Water Biowasher is compatible with a range of Stomacher® bags. The BA6042 Standard 3500 bag (60 microns), which suits standard operations. The BA6042/HD Heavy Duty bag designed to serve resilient applications with a greater bag thickness of 80 microns. As well as the latest in innovation, the new Autoclavable Stomacher® 3500 bag. The first paddle blender bag designed to also be autoclavable for sterility methods post-testing.
Technical Specifications
Sample Size |
400ml – 3500ml |
---|
Product codes | 3500/001/EU 030010353 |
3500/001/AJ 030010302 |
Supply voltage: | 220-250V | 110-120V |
Mains Inlet Fuses: | T800mA 250V 5x20mm breaking capacity: 35A @ 250V |
T2.0A 250V 5x20mm breaking capacity: 100A @ 250V |
Supply Frequency: 50-60Hz | 50-60Hz |
Plug Top Fuse: | F5A (UK cord set only) |
Transformer Fuse: | Jumbo |
PCB Fuse: | F2.5A 250V 5x20mm, breaking capacity: 100A @ 250V |
Insulation: | Class 1 (Earthed) |
Installation: | Over Voltage Category II |
Pollution: | Pollution Degree 2 |
Duty Cycle: | Continuous |
Rated Load: | 120W |
Adjustable paddles: | Patented |
Warranty: | 3 years |
Service and support: | 10 years |
Dimensions: | 480mm(w) x 480mm(d) x 445mm(h) |
Dimensions (Packed): | 600mm(w) x 600mm(d) x 580mm(h) |
Weight: | 36kg |
Weight (Packed): | 42kg |
Compliant with: | EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Machinery Directive 2006/42/CE IEC61010-1 1990 Safety Requirement for Electrical Equipment for Measurement, Control and Laboratory Use UL 3101-1 1993 Electrical Equipment for Laboratory Use General Requirements |
Delivered with: | Power Cable / Quick Start Guide Sachet of BA6042 Standard Stomacher bags |
Bag sizes: | 508mm(l) x 380mm(w) |
Available in: | Standard / Closure / Autoclavable |
Minimum recommended capacity: | 1000ml |
Maximum recommended capacity: | 3500ml |
Maximum Recommended Sample Temp: | 60°C |
Recommended Operating Ambient Temperature Range: | 10-35°C |
Recommended Operating Relative Humidity Range: | 10-89% |
Fixed Timer settings: | 30 secs (+/-5%) 60 secs (+/-5%) 120 sec (+/-5%) Continuous |
No load paddle speeds: (@nominal 20°C) |
125rpm (±5%)LOW 150rpm (±5%) NORM 175rpm (±5%) HIGH |
Paddle Clearance: | 0-20mm |