The SG-Ultra Max Plus battery hydrometer measures the density and density-related values of your sample within seconds. Results appear on the large color touch screen and are ready for storage, printout or export to a PC. The lightweight and robust design enable on-site operation in a wide range of environments. Completely sealed, pump spills do not enter the instrument.
The design features a leak-proof housing for operation in industrial and field applications including battery testing for utilities and telecoms, food & beverage testing, quality control, biotechnology, and many more. Supported measuring units include: density, density at reference temperature, specific gravity, alcohol, API, °Baumé, °Brix, and ten programmable custom functions to ensure your measurement requirements.
SG-Ultra Max Plus Kit Includes:
- SG-Ultra Max Plus
- 180 mm Sample Tube
- 2 mL Plastic Syringes
- Luer Adapter 1/4” UNF
- Bluetooth Adapter
- Carrying Case
- Electronic User Manual
Benefits
- 99.999% Accurate, tests density and temperature simultaneously
- User-Friendly Compact, lightweight, and allows for one-hand measurement
- Robust & rugged, comes with protective carrying case. Measuring cell can be exchanged and replaced if necessary
- Wireless Communication via Bluetooth or data exchange with a PC and data export to a printer
- Stores up to 1,024 total measurement results including time stamp and sample ID
- Automatic temperature compensation
Technical Data
Measurement Range: | Density: 0.000 – 3.000 g/cm3 Sample Temperature: 01 – 40 °C (321 – 104 °F) Viscosity: 0 – 1,000 mPa |
---|---|
Accuracy: | Density: 0.001 g/cm3 Temperature: ±0.2 °C (±0.4 °F) |
Resolution: | 0.0001 g/cm3 |
Repeatability: | 0.0005 g/cm3 |
Minimum Sample Volume: | 2 mL |
Communication: | Bluetooth, RFID |
Display: | Backlit color with capacitive touch controls |
Internal Storage: | 1024 Results |
Operating Environment: | -10 – 50 °C (14 – 122 °F) |
Power Requirements: | (3) 1.5 V LR06 AA Alkaline Batteries |
Dimensions: | 245 x 103 x126 mm (9.6 x 4 x 5 in) |
Weight: | 660 g (23.3 oz) |
(1) Sample must not freeze in the measuring cell
-
ManufacturerEagle Eye Power Solutions, LLC
-
Country of OriginUnited States
-
Measurement Range:Density: 0.000 – 3.000 g/cm3 Sample Temperature: 01 – 40 °C (321 – 104 °F) Viscosity: 0 – 1,000 mPa
-
Accuracy:Density: 0.001 g/cm3 Temperature: ±0.2 °C (±0.4 °F)
-
Resolution:0.0001 g/cm3
What is the measurement range of the SG-Ultra Max Plus Digital Hydrometer / Density Meter?
The density range is 0.000-3.000 g/cm3
Does the SG-Ultra Max Plus work with my solution?
The SG-Ultra Max Plus works with a vast range of solutions across many unique industries. The best method to verify if the unit will work with your solution is to compare the Ultra Max wetted parts list with a chemical compatibility chart of your solution (parts list found below):
SG Ultra Max Wetted Parts List:
- Borosilicate glass Measuring cell, pump cylinder
- PP (Polypropylene) Faradex MS002 Housing
- PVDF (Polyvinylidene fluoride) Connection block, bolt
- Viton O-ring
How accurate is the SG-Ultra Max Plus?
The SG-Ultra Max Plus is accurate to 0.001g/cm3 with repeatability of 0.0005
How does the SG-Ultra Max Plus communicate?
The Ultra Max utilizes Bluetooth and RFID.
What is the measurement range of the SG-Ultra Max Plus?
The density range is 0.000-3.000 g/cm3
How long does the SG-Ultra Max Plus take to display measurement results?
Measurement times vary depending on unit and sample temperature. The sample will have to equilibrate inside the measuring cell. This process generally takes only a few seconds but in some situations may take up to a minute
How many measurements does they SG-Ultra Max Plus Density Meter store?
The maximum stored results are 1,024
What file format is the data imported to the PC as?
Data is exported from the SG-Ultra Max Plus as either a CSV or TXT file. This can be viewed using Microsoft Excel or Exmons Ultra Plus software
What is the maintenance for the SG-Ultra Max Plus digital hydrometer?
Precise measurements demand a well-functioning precision tool. The device should be cleaned after each use. The consumable parts of the Ultra Max should be monitored closely and replaced regularly as needed
How often should I calibrate my SG-Ultra Max Plus digital hydrometer?
It is recommended to have the unit calibrated annually