LAUDA L002901 H 8 Hydro Water Bath, 8 Litre Capacity , 230V 50/60 Hz Schuko Plug
Hydro H 8 Specifications
- This model replaced the GFL 1102
The water baths of the LAUDA Hydro series are optimally equipped for every application in the laboratory and ensure a homogeneous temperature distribution without local overheating. LAUDA Hydro water baths with precise temperature distribution and optional circulation are designed for the needs of biological, medical or biochemical laboratories.
designation
value
Working temperature min.
25 ° C
Working temperature max.
100 ° C
Ambient temperature min.
10 ° C
Ambient temperature max.
40 ° C
Constant temperature
0.1 ± K
application
In the bathroom
heating capacity
1 kW
Power consumption
Bath volume min.
Bath volume max.
8 L
Bath opening width
245 mm
Bath opening depth
200 mm
Bath depth
165 mm
Height of top edge of bathroom without gable hood
Height including gable hood
-
LAUDA L002954 H 8 Hydro Water Bath, 8 Litre Capacity , 230V 50/60 Hz UK Plug
Hydro H 8 Specifications
- This model replaced the GFL 1102
The water baths of the LAUDA Hydro series are optimally equipped for every application in the laboratory and ensure a homogeneous temperature distribution without local overheating. LAUDA Hydro water baths with precise temperature distribution and optional circulation are designed for the needs of biological, medical or biochemical laboratories.
designation
value
Working temperature min.
25 ° C
Working temperature max.
100 ° C
Ambient temperature min.
10 ° C
Ambient temperature max.
40 ° C
Constant temperature
0.1 ± K
application
In the bathroom
heating capacity
1 kW
Power consumption
Bath volume min.
Bath volume max.
8 L
Bath opening width
245 mm
Bath opening depth
200 mm
Bath depth
165 mm
Height of top edge of bathroom without gable hood
Height including gable hood
-
LAUDA L002906 H 8 A Hydro Water Bath, 8 Litre Capacity , 230V 50/60 Hz Schuko Plug
Hydro H 8 A Specifications
- This model replaced the GFL 1112
The water baths of the LAUDA Hydro series are optimally equipped for every application in the laboratory and ensure homogeneous temperature distribution without local overheating. LAUDA Hydro water baths with precise temperature distribution and optional circulation are designed for the needs of biological, medical or biochemical laboratories. The two circulation water baths H 8 A and H 16 A have integrated the circulation system as standard.
Designation
Value
Working temperature min.
25 °C
Working temperature max.
100 °C
Ambient temperature min.
10 °C
Ambient temperature max.
40 °C
Temperature stability
0.1 ±K
Application
Inside the bath
Heater power
1 kW
Loading
Bath volume min.
Bath volume max.
8 L
Bath opening width
245 mm
Bath opening depth
200 mm
Bath depth
165 mm
Height top edge bath without gable cover
Height incl. gable cover
-
LAUDA L002959 H 8 A Hydro Water Bath, 8 Litre Capacity , 230V 50/60 Hz UK Plug
Hydro H 8 A Specifications
- This model replaced the GFL 1112
The water baths of the LAUDA Hydro series are optimally equipped for every application in the laboratory and ensure homogeneous temperature distribution without local overheating. LAUDA Hydro water baths with precise temperature distribution and optional circulation are designed for the needs of biological, medical or biochemical laboratories. The two circulation water baths H 8 A and H 16 A have integrated the circulation system as standard.
Designation
Value
Working temperature min.
25 °C
Working temperature max.
100 °C
Ambient temperature min.
10 °C
Ambient temperature max.
40 °C
Temperature stability
0.1 ±K
Application
Inside the bath
Heater power
1 kW
Loading
Bath volume min.
Bath volume max.
8 L
Bath opening width
245 mm
Bath opening depth
200 mm
Bath depth
165 mm
Height top edge bath without gable cover
Height incl. gable cover
-
KGW Isotherm Glass Refills for Dewar Flasks Cylindrical
- Special manufactured products are excluded from being returned
-
Daicel AC345 DCpak® PTZ HILIC SFC ACHIRAL Semi-Preparative Column, 20mm, 250mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC344 DCpak® PTZ HILIC SFC ACHIRAL Semi-Preparative Column, 20mm, 150mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
CERI 742230 L-column2 ODS C18 Octadecyl Semi Preparative HPLC Column, 20mm x 50mm, 5μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
CERI 742520 L-column2 ODS C18 Octadecyl Semi Preparative HPLC Column, 20mm x 150mm, 5μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
CERI 742120 L-column2 ODS C18 Octadecyl Semi Preparative HPLC Column, 20mm x 250mm, 5μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
CERI 741230 L-column2 ODS C18 Octadecyl Semi Preparative HPLC Column, 20mm x 50mm, 3μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
Daicel AC335 DCpak® PTZ HILIC SFC ACHIRAL Semi-Preparative Column, 10mm, 250mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC334 DCpak® PTZ HILIC SFC ACHIRAL Semi-Preparative Column, 10mm, 150mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC582 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 3mm, 50mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC583 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 3mm, 100mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC584 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 3mm, 150mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC585 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 3mm, 250mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC324 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 150mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC325 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 250mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC394 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 2.1mm, 150mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC395 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 2.1mm, 250mm, 5µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC522 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 50mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC523 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 100mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC524 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 150mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC525 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 4.6mm, 250mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC592 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 2.1mm, 50mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC593 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 2.1mm, 100mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
Daicel AC594 DCpak® PTZ HILIC SFC ACHIRAL Analytical Column, 2.1mm, 150mm, 3µm
Filler particle size DAICEL DCpak ® PTZ: 3μm
pressure In order to extend the service life of the chiral column, it is recommended to keep the pressure below 30 MPa. pH value pH 2.0 ~ 8.0 temperature 5~40°C Storage solvent Water / acetonitrile = 10/90 (v / v)
-
CERI 752110 L-column2 ODS C18 Octadecyl HPLC Guard Column (10.0–20.0 mm ID), 10mm x 20mm, 5μm Particle Size
Connection type: 1/16 inch Waters (W)
A tube and a connector, used to connect a guard column to an analytical column, are not attached.
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
Nacalai Tesque 13790-31 COSMOSIL HP (3-Hydroxyphenyl) SFC Column, 20mm, 250mm, 5µm
Supercritical Fluid Chromatography (SFC) has become more attractive because it offers some advantages over HPLC, such as high speed, unique selectivity and environmentally friendly separations. Many conventional normal-phase stationary phases, such as diol, amino and cyano, have been used for SFC applications. However, these phases present limitations for separations. COSMOSIL SFC Columns have been developed to enhance the capability of SFC separations. -
Nacalai Tesque 13791-21 COSMOSIL HP (3-Hydroxyphenyl) Guard SFC Column, 10mm, 20mm, 5µm
Supercritical Fluid Chromatography (SFC) has become more attractive because it offers some advantages over HPLC, such as high speed, unique selectivity and environmentally friendly separations. Many conventional normal-phase stationary phases, such as diol, amino and cyano, have been used for SFC applications. However, these phases present limitations for separations. COSMOSIL SFC Columns have been developed to enhance the capability of SFC separations. -
CERI 711770 L-column2 ODS C18 Octadecyl HPLC Column, 2.1mm x 20mm, 3μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS exceeds even the high performance of L-column ODS by virtue of its advanced new end-capping method. It accommodates the analysis of acidic, basic and chelating compounds.
- Sharper peaks for acidic, basic and chelating compounds due to extremely low silanol adsorption.
- Superior peak shapes in both acetonitrile/water and methanol/water mobile phases makes L-column2 ODSconvenient to use.
- Economical due to high durability in a wide range of pH and temperature.
- Uniform lot to lot reproducibility of analyses due to extensive quality control measures.
-
CERI 711771 L-column2 C8 Octyl HPLC Column, 2.1mm x 20mm, 3μm Particle Size
Average particle size: 3 µm, 5 µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 10 % Bonded phase: C8 (Octyl) End-capping: Yes USP category: L7 Range of pH: pH 2 – pH 7.5 L- column 2 C8 is a next-generation high performance octyl group column that suppresses the influence of residual silanol groups to the utmost by advanced end-capping method and exceeds L-column C8 . It is a column that is easy to use with high durability, as well as detecting peaks sharply. It is ideal for shortening the analysis time of hydrophobic substances and concomitant solvent saving
-
CERI 711776 L-column2 C6 Phenyl-Hexyl HPLC Column, 2.1mm x 20mm, 3μm Particle Size
Particle size 3 μm, 5 μm Pore size 12 nm Specific surface area 340 m 2 / g Carbon content 13% Modifying group Phenylhexyl group End capping method Advanced End Capping USP category L 11 Used pH range pH 2 to pH 7.5 L- column 2 C6-Phenyl is a next-generation high-performance phenyl column that combines the separation properties of phenylhexyl column and low adsorption by the high end capping of L-column 2
-
CERI 713770 L-column2 ODS C18 Octadecyl HPLC Column, 2.1mm x 20mm, 2μm Particle Size
Average particle size: 2µm, 3µm, 5µm Average pore size: 120 Å Surface area: 340 m2/g Carbon contents: 17 % Bonded phase: C18 (Octadecyl) End-capping: Yes USP category: L1 Range of pH: pH 2 – pH 9 L-column2 ODS, 2μm was developed with usability in mind. Its low pressure reduces the load of columns and equipment, and its high durability provides a high theoretical plate number for a wide range of mobile phase flow rates. Therefore, L-column2 ODS, 2μm is an ideal 2-μm particle column