Technical Data
Model | HBC 5 Basic | HBC 5 Control | HBC 10 Basic | HBC 10 Control |
Appliance type | Circulation thermostat | Circulation thermostat | Circulation thermostat | Circulation thermostat |
Class designation acc. DIN 12876 | III | III | III | III |
Identification according to DIN 12876 | FL | FL | FL | FL |
Heat output | 2500 W | 2500 W | 2500 W | 2500 W |
Working temperature min. | room temp. +10K @1000rpm °C | room temp. +10K @1000rpm °C | room temp. +10K @1000rpm °C | room temp. +10K @1000rpm °C |
Working temperature max. | 250 °C | 250 °C | 250 °C | 250 °C |
Operating temperature min. (with external cooling) | -20 °C | -20 °C | -20 °C | -20 °C |
Temperature display | yes | yes | yes | yes |
Temperature control | PID | PID | PID | PID |
Working temperature sensor | PT 100 | PT 100 | PT 100 | PT 100 |
Safety temperature sensor | PT1000 | PT1000 | PT1000 | PT1000 |
Working temperature display | LED | TFT | LED | TFT |
Safety temperature display | LED | TFT | LED | TFT |
Temperature stability DIN 12876 | ±0.02 K | ±0.01 K | ±0.02 K | ±0.01 K |
Connection for ext. temperature sensor | PT 100 | PT 100 | PT 100 | PT 100 |
Display resolution | 0.1 K | 0.01 K | 0.1 K | 0.01 K |
Display for operation with ext. sensor | yes | yes | yes | yes |
Set temperature resolution | ±0.1 K | ±0.1 K | ±0.1 K | ±0.1 K |
Warning function optical | yes | yes | yes | yes |
Warning function acoustic | yes | yes | yes | yes |
Warning function excess temperature | yes | yes | yes | yes |
Adjustable safety circuit min. | 0 °C | 0 °C | 0 °C | 0 °C |
Adjustable safety circuit max. | 260 °C | 260 °C | 260 °C | 260 °C |
Sub-level protection | yes | yes | yes | yes |
Over-level protection | yes | yes | yes | yes |
Filling volume min. | 5 l | 5 l | 8 l | 8 l |
Filling volume max. | 7 l | 7 l | 11 l | 11 l |
Pump type | Pressure- / suction pump | Pressure- / suction pump | Pressure- / suction pump | Pressure- / suction pump |
Pump capacity adjustable | yes | yes | yes | yes |
Pump pressure max. (0 liters discharge flow) | 0.61 bar | 0.61 bar | 0.61 bar | 0.61 bar |
Pressure pump (suction side) (0 liter flow) | 0.45 bar | 0.45 bar | 0.45 bar | 0.45 bar |
Flow rate max. (0 bar back pressure) | 31 l/min | 31 l/min | 31 l/min | 31 l/min |
Pump connection | M16x1 | M16x1 | M16x1 | M16x1 |
Cooling coil connection | NW 8 | NW 8 | NW 8 | NW 8 |
Bath depth min. | 150 mm | 150 mm | 150 mm | 150 mm |
Width bath opening | 172 mm | 172 mm | 172 mm | |
Depth bath opening | 82 mm | 82 mm | 82 mm | |
Calibration option | yes | yes | yes | yes |
Technical data complies with the standard | DIN 12876 | DIN 12876 | DIN 12876 | DIN 12876 |
Permissible ON time | 100 % | 100 % | 100 % | 100 % |
Multi-Interface | yes | yes | ||
Alarm output (potential-free contact) max. | 30 V AC/DC | 30 V AC/DC | ||
Alarm output (potential-free contact) max. | 1 A | 1 A | ||
Solenoid valve output | 24 VDC | 24 VDC | ||
Solenoid valve output max. | 0.8 A | 0.8 A | ||
Standby input | 5 VDC | 5 VDC | ||
Width | 275 mm | 275 mm | 275 mm | 275 mm |
Depth | 500 mm | 500 mm | 500 mm | 506 mm |
Height | 406 mm | 406 mm | 456 mm | 456 mm |
Weight | 17 kg | 17.3 kg | 18 kg | 18.3 kg |
Permissible ambient temperature min. | 5 °C | 5 °C | 5 °C | 5 °C |
Permissible ambient temperature max. | 40 °C | 40 °C | 40 °C | 40 °C |
Permissible relative humidity | 80 % | 80 % | 80 % | 80 % |
Protection class according to DIN EN 60529 | IP 21 | IP 21 | IP 21 | IP 21 |
RS 232 interface | yes | yes | yes | yes |
USB interface | yes | yes | yes | yes |
Voltage | 230 / 100 - 115 V | 230 / 100 - 115 V | 230 / 100 - 115 V | 230 / 100 |
Frequency | 50/60 Hz | 50/60 Hz | 50/60 Hz | 50/60 Hz |
Power input | 2650 W | 2650 W | 2650 W | 2650 W |