More search options
8 products found
    • £1379.00
  • Hanna HI-83399 Water and Wastewater Multi-Parameter with COD Photometer & pH Meter

    One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.

    40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter.

    Specifications

    Input Channels1 pH electrode input and 5 photometer wavelengths
    pH ElectrodeDigital pH electrode (not included)
    Logging typeLog on demand with user name and sample ID optional input
    Logging Memory1000 readings
    ConnectivityUSB-A host for flash drive; micro-USB-B for power and computer connectivity
    GLPCalibration data for connected pH electrode
    Display128 x 64 pixel LCD with backlight
    Battery Type/Life3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
    Power supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
    Dimensions206 x 177 x 97mm (8.1 x 7.0 x 3.8")
    Weight1.0 kg (2.2lbs)
    Photometer/Colorimeter Light Source5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
    Photometre/Colorimeter Light DetectorSilicon Photodetector
    Bandpass filter Bandwidth8nm
    Bandpass filter wavelength accruacy+-1nm
    Cuvette TypeRound, 24.6mm
    Number of Methods128 Max
    Ordering InformationHI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
    Price Upon Application Or Discontinued
  • Hanna HI-83314-02 Multi-parameter Wastewater & Water Photometer with COD and pH meter

    One meter can be used for both photometric and pH measurements. HI-83314 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. Ten key water and wastewater quality parameters with 20 different methods.

    Specifications

    Input Channels1 pH electrode input and 5 photometer wavelengths
    pH ElectrodeDigital pH electrode (not included)
    Logging typeLog on demand with user name and sample ID optional input
    Logging Memory1000 readings
    ConnectivityUSB-A host for flash drive; micro-USB-B for power and computer connectivity
    GLPCalibration data for connected pH electrode
    Display128 x 64 pixel LCD with backlight
    Battery Type/Life3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement
    Power supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
    Environment0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing
    Dimensions206 x 177 x 97mm (8.1 x 7.0 x 3.8")
    Weight1.0 kg (2.2lbs)
    Photometer/Colorimeter Light Source5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters
    Photometre/Colorimeter Light DetectorSilicon Photodetector
    Bandpass filter Bandwidth8nm
    Bandpass filter wavelength accruacy+-1nm
    Cuvette TypeRound, 24.6mm
    Number of Methods128 Max
    Ordering InformationHI-83314 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.
    Price Upon Application Or Discontinued
  • WLD-TEC 8.200.000 Fuego SCS Safety Enhanced Laboratory Gas Burner with touch free IR-sensor and button function

    Technology

    Microprocessor, illuminated graphic display with acoustic signals as operating aids

    6 Programs
    IR-Sensor:


    Foot pedal:


    Button:

    Temperature regulation:


    Start-Stop with timer, 1 sec - 2 h
    Auto-Off with timer, 0 sec - 2 h

    Standard (flame during pressed foot pedal)
    Start-Stop with timer, 1 sec - 2 h

    Start-Stop with timer, 1 sec - 2 h

    with timer, 1 sec - 2 h
    temperature range from +35 °C to +350 °C

    Safety features
    Safety Control System (SCS)
    with gas safety cut off:



    Residual heat display:

    Zero-Pressure shut-off:



    ignition and flame control, temperature monitor
    burner head clogging and assembly monitor (BHC)
    automatic unit switch off after 1 - 2h, adjustable

    indicated a hot burner head

    end of work procedure to lower the pressure in the supply hose

    Comfort functions

    cooling reminder
    gas consumption display for gas cartridges

    Gas supply & consumption 
    Gas connection:

    Gas types:


    Connected load:

    Continuous cartridge operation:

     

     


    1/4” left with gas filter

    II2ELL3B/P: natural gas E/LL,18 - 25 mbar
    liquid gas, 47,5 - 57,5 mbar

    70 g/h liquid gas; 95 l/h natural gas (LL)

    CV 360 - 40 min,
    Express 444 - 50 min,
    CG 1750 - 150 min,
    C 206 - 170 min,
    CP 250 - 210 min,
    CV 470 - 370 min

    Temperatures
    Flame temperature:


    Temperature threshold level:


    1350 °C on liquid gas
    1300 °C on natural gas (E)

    1.0 kW liquid gas, 1.0 kW natural gas

    Electrical 
    IR-Sensor detection range:
    DoubleClick IR-Sensor:

    Power consumption:
    Switching power supply:


    5 - 50 mm, adjustable
    time range 0.5 - 2.5 sec (adjust. / disengageable)

    2 VA (stand by max. 0.1 VA)
    100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A
    Level 6 (stand by power consumption max. 0.1W)

    Mechanical
    Casing & operating controls:
    Burner head:
    Cover of burner shaft:

    Measurements (w x h x d):
    Weight:


    stainless steel / glass, UV and solvent resistant
    removable and decomposable, stainless steel
    Ø 23 mm, with drains

    103 x 49 x 130 mm
    700 g

    Licenses 
    DIN-DVGW Reg.-No.:
    CE:
    EU guidelines:


    NG-2211AS0167
    EN 61326-1, EN61010-1, EN61010-2-010
    2014/30/EU, 2014/35/EU, 2011/65/EU

    Price Upon Application Or Discontinued
  • WLD-TEC 8.204.000 Fuego SCS pro Safety Enhanced Laboratory Gas Burner, battery operated with touch free IR-sensor and button function

    Technology

    Microprocessor, illuminated graphic display with acoustic signals as operating aids

    6 Programs
    IR-Sensor:


    Foot pedal:


    Button:

    Temperature regulation:


    Start-Stop with timer, 1 sec - 2 h
    Auto-Off with timer, 0 sec - 2 h

    Standard (flame during pressed foot pedal)
    Start-Stop with timer, 1 sec - 2 h

    Start-Stop with timer, 1 sec - 2 h

    with timer, 1 sec - 2 h
    temperature range from +35 °C to +350 °C

    Safety features
    Safety Control System (SCS)
    with gas safety cut off:




    Residual heat display:

    Zero-Pressure shut-off:



    ignition and flame control, temperature monitor
    burner head clogging and assembly monitor (BHC)
    automatic unit switch off after 1 - 2h, adjustable
    tilt sensor (>90°)

    indicated a hot burner head

    end of work procedure to lower the pressure in the supply hose

    Comfort functions

    cooling reminder
    gas consumption display for gas cartridges

    Gas supply and consumption 
    Gas connection:

    Gas types:


    Connected load:

    Continuous cartridge operation:

     

     

     


    1/4” left with gas filter

    II2ELL3B/P: natural gas E/LL,18 - 25 mbar
    liquid gas, 47,5 - 57,5 mbar

    70 g/h liquid gas; 95 l/h natural gas (LL)

    CV 360 - 40 min,
    Express 444 - 50 min,
    CG 1750 - 150 min,
    C 206 - 170 min,
    CP 250 - 210 min,
    CV 470 - 370 min

    Temperatures
    Flame temperature:


    Temperature threshold level:


    1350 °C on liquid gas
    1300 °C on natural gas (E)

    1.0 kW liquid gas, 1.0 kW natural gas

    Electrical 
    IR-Sensor detection range:
    DoubleClick IR-Sensor:

    Power consumption:
    Switching power supply:


    5 - 50 mm, adjustable
    time range 0.5 - 2.5 sec (adjust. / disengageable)

    2 VA (stand by max. 0.1 VA)
    100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A
    Level 6 (stand by power consumption max. 0.1W)

    Technical Data Battery Operation
    Type:

    Operating time:

    Charging time:
    Charging current:



    NIHM 2.4V (2 x Mignon (AA) rechargeable battery, 1.2V 2600mAh)
    up to 9 hours of continuous start/stop operation
    (up to 2000 inoculation loop annealing operations)

    90% / 3 hours
    700 mA

    Mechanical
    Casing and operating controls:
    Burner head:
    Cover of burner shaft:

    Measurements (w x h x d):
    Weight:


    stainless steel / glass, UV and solvent resistant
    removable and decomposable, stainless steel
    Ø 23 mm, with drains

    103 x 49 x 130 mm
    700 g

    Licenses 
    DIN-DVGW Reg.-No.:
    CE:
    EU guidelines:


    NG-2211AS0167
    EN 61326-1, EN 61010-1, EN 61010-2-010
    2014/30/EU, 2014/35/EU, 2011/65/EU  

    Price Upon Application Or Discontinued