Hanna HI-83399 Water and Wastewater Multi-Parameter with COD Photometer & pH Meter
One meter can be used for both photometric and pH measurements. HI-83399 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available, with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and imperfections in the glass cuvette.
40 key water and wastewater quality parameters with 73 different methods covering multiple ranges are programmed into the meter.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83399 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. -
Hanna HI-83314-02 Multi-parameter Wastewater & Water Photometer with COD and pH meter
One meter can be used for both photometric and pH measurements. HI-83314 is a compact, multi-parameter photometer for measuring key water and wastewater quality parameters. The meter is one of the most advanced photometers available with an innovative optical design that utilises a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. Ten key water and wastewater quality parameters with 20 different methods.
Specifications
Input Channels 1 pH electrode input and 5 photometer wavelengths pH Electrode Digital pH electrode (not included) Logging type Log on demand with user name and sample ID optional input Logging Memory 1000 readings Connectivity USB-A host for flash drive; micro-USB-B for power and computer connectivity GLP Calibration data for connected pH electrode Display 128 x 64 pixel LCD with backlight Battery Type/Life 3.7 VDC Li-polymer rechargeable battery/ >500 photometric measurements or 50 hours of continuous pH measurement Power supply 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included) Environment 0 to 50.0°C (32 to 122.0°F; 0 to 95% RH, non-condensing Dimensions 206 x 177 x 97mm (8.1 x 7.0 x 3.8") Weight 1.0 kg (2.2lbs) Photometer/Colorimeter Light Source 5 LEDs with 420nm, 466nm, 525nm, 575nm, and 610nm narrow band interference filters Photometre/Colorimeter Light Detector Silicon Photodetector Bandpass filter Bandwidth 8nm Bandpass filter wavelength accruacy +-1nm Cuvette Type Round, 24.6mm Number of Methods 128 Max Ordering Information HI-83314 is supplied with sample cuvettes and caps (x4), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual. -
WLD-TEC 8.200.000 Fuego SCS Safety Enhanced Laboratory Gas Burner with touch free IR-sensor and button function
Technology
Microprocessor, illuminated graphic display with acoustic signals as operating aids
6 Programs
IR-Sensor:
Foot pedal:
Button:
Temperature regulation:
Start-Stop with timer, 1 sec - 2 h
Auto-Off with timer, 0 sec - 2 h
Standard (flame during pressed foot pedal)
Start-Stop with timer, 1 sec - 2 h
Start-Stop with timer, 1 sec - 2 h
with timer, 1 sec - 2 h
temperature range from +35 °C to +350 °CSafety features
Safety Control System (SCS)
with gas safety cut off:
Residual heat display:
Zero-Pressure shut-off:
ignition and flame control, temperature monitor
burner head clogging and assembly monitor (BHC)
automatic unit switch off after 1 - 2h, adjustable
indicated a hot burner head
end of work procedure to lower the pressure in the supply hoseComfort functions
cooling reminder
gas consumption display for gas cartridgesGas supply & consumption
Gas connection:
Gas types:
Connected load:
Continuous cartridge operation:
1/4” left with gas filter
II2ELL3B/P: natural gas E/LL,18 - 25 mbar
liquid gas, 47,5 - 57,5 mbar
70 g/h liquid gas; 95 l/h natural gas (LL)
CV 360 - 40 min,
Express 444 - 50 min,
CG 1750 - 150 min,
C 206 - 170 min,
CP 250 - 210 min,
CV 470 - 370 minTemperatures
Flame temperature:
Temperature threshold level:
1350 °C on liquid gas
1300 °C on natural gas (E)
1.0 kW liquid gas, 1.0 kW natural gasElectrical
IR-Sensor detection range:
DoubleClick IR-Sensor:
Power consumption:
Switching power supply:
5 - 50 mm, adjustable
time range 0.5 - 2.5 sec (adjust. / disengageable)
2 VA (stand by max. 0.1 VA)
100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A
Level 6 (stand by power consumption max. 0.1W)Mechanical
Casing & operating controls:
Burner head:
Cover of burner shaft:
Measurements (w x h x d):
Weight:
stainless steel / glass, UV and solvent resistant
removable and decomposable, stainless steel
Ø 23 mm, with drains
103 x 49 x 130 mm
700 gLicenses
DIN-DVGW Reg.-No.:
CE:
EU guidelines:
NG-2211AS0167
EN 61326-1, EN61010-1, EN61010-2-010
2014/30/EU, 2014/35/EU, 2011/65/EU -
WLD-TEC 8.204.000 Fuego SCS pro Safety Enhanced Laboratory Gas Burner, battery operated with touch free IR-sensor and button function
Technology
Microprocessor, illuminated graphic display with acoustic signals as operating aids
6 Programs
IR-Sensor:
Foot pedal:
Button:
Temperature regulation:
Start-Stop with timer, 1 sec - 2 h
Auto-Off with timer, 0 sec - 2 h
Standard (flame during pressed foot pedal)
Start-Stop with timer, 1 sec - 2 h
Start-Stop with timer, 1 sec - 2 h
with timer, 1 sec - 2 h
temperature range from +35 °C to +350 °CSafety features
Safety Control System (SCS)
with gas safety cut off:
Residual heat display:
Zero-Pressure shut-off:
ignition and flame control, temperature monitor
burner head clogging and assembly monitor (BHC)
automatic unit switch off after 1 - 2h, adjustable
tilt sensor (>90°)
indicated a hot burner head
end of work procedure to lower the pressure in the supply hoseComfort functions
cooling reminder
gas consumption display for gas cartridgesGas supply and consumption
Gas connection:
Gas types:
Connected load:
Continuous cartridge operation:
1/4” left with gas filter
II2ELL3B/P: natural gas E/LL,18 - 25 mbar
liquid gas, 47,5 - 57,5 mbar
70 g/h liquid gas; 95 l/h natural gas (LL)
CV 360 - 40 min,
Express 444 - 50 min,
CG 1750 - 150 min,
C 206 - 170 min,
CP 250 - 210 min,
CV 470 - 370 minTemperatures
Flame temperature:
Temperature threshold level:
1350 °C on liquid gas
1300 °C on natural gas (E)
1.0 kW liquid gas, 1.0 kW natural gasElectrical
IR-Sensor detection range:
DoubleClick IR-Sensor:
Power consumption:
Switching power supply:
5 - 50 mm, adjustable
time range 0.5 - 2.5 sec (adjust. / disengageable)
2 VA (stand by max. 0.1 VA)
100-240V / 50/60Hz / max. 0.3 A; 9V DC / 1.3A
Level 6 (stand by power consumption max. 0.1W)Technical Data Battery Operation
Type:
Operating time:
Charging time:
Charging current:
NIHM 2.4V (2 x Mignon (AA) rechargeable battery, 1.2V 2600mAh)
up to 9 hours of continuous start/stop operation
(up to 2000 inoculation loop annealing operations)
90% / 3 hours
700 mAMechanical
Casing and operating controls:
Burner head:
Cover of burner shaft:
Measurements (w x h x d):
Weight:
stainless steel / glass, UV and solvent resistant
removable and decomposable, stainless steel
Ø 23 mm, with drains
103 x 49 x 130 mm
700 gLicenses
DIN-DVGW Reg.-No.:
CE:
EU guidelines:
NG-2211AS0167
EN 61326-1, EN 61010-1, EN 61010-2-010
2014/30/EU, 2014/35/EU, 2011/65/EU
8 products found
Sort by:
Recommended