Grant Bio RTS Single Use Reverse Spin Personal Bioreactors for Mixing and Oxygenating
The Grant Bio RTS Single-Use Reverse Spin Personal Bioreactors are innovative and specialized bioreactor systems designed for mixing and oxygenating biological samples, particularly for applications such as cell culture, fermentation, and bioprocessing. These bioreactors are highly suitable for research and small-scale production where precision, flexibility, and ease of use are key requirements.
RTS-1 is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.
Software features:
Typical applications:
|
RTS-1C is personal bioreactor which utilize patented Reverse-Spin® technology that applies non-invasive, mechanically driven, low energy consumption, innovative type of agitation where cell suspension is mixed by the singleuse falcon bioreactor tube rotation around its axis with a change of direction of rotation motion resulting in highly efficient mixing and oxygenation for aerobic cultivation. Combined with a near-infrared optical system it is possible to register cell growth kinetics non-invasively in real time.
Software features:
Typical applications:
|
Model | RTS-1 | RTS-1C |
---|---|---|
Measurement range | 0–10 OD at 10–20ml volume (0–19 OD λ600 nm equivalent) 0–8 OD at 20–30ml volume (0–15.2 OD λ600 nm equivalent) |
0–10 OD at 10–20ml volume (0–19 OD λ600 nm equivalent) 0–8 OD at 20–30ml volume (0–15.2 OD λ600 nm equivalent) |
Measurement precision | ±0.3 OD | ±0.3 OD |
Light source | NIR Light diode | NIR Light diode |
Measurement wavelength (λ) | 850 nm | 850 nm |
Measurement periodicity per hour | 1–60 | 1–60 |
Cultural media volume | 10–30 ml | 10–30 ml |
Temperature setting range | +25°C ... +70°C | +4°C ... +70°C |
Temperature control range | 5°C above ambient ... +70°C | 15°C below ambient ... +70°C |
Temperature stability | ±0.1°C | ±0.1°C |
Display | LCD | LCD |
Speed control range | 50–2,000 rpm | 50–2,000 rpm |
Max. number of units connected to the software | 10 | 10 |
Type of tube for aerobic cultivation | 50 ml tube with membrane filter (TubeSpin® Bioreactor 50, TPP®)* | 50 ml tube with membrane filter (TubeSpin® Bioreactor 50, TPP®)* |
Type of tube for anaerobic cultivation | 50 ml tube with membrane filter (TubeSpin® Bioreactor 50, TPP®)* * — it is also possible to use other manufacturer tubes of the same type, e.g. Corning® 50ml Mini Bioreactor, but the device rotor must be modified. It is possible to request this modif. |
50 ml tube with membrane filter (TubeSpin® Bioreactor 50, TPP®)* * — it is also possible to use other manufacturer tubes of the same type, e.g. Corning® 50ml Mini Bioreactor, but the device rotor must be modified. It is possible to request this modif. |
Minimum PC requirements | Intel/AMD Processor, 1 GB RAM Windows Vista/7/8/8.1/10/11, USB 2.0 port | Intel/AMD Processor, 1 GB RAM Windows Vista/7/8/8.1/10/11, USB 2.0 port |
Optimal PC requirements | Intel/AMD Processor, 3 GB RAM Windows Vista/7/8/8.1/10/11, USB 2.0 port | Intel/AMD Processor, 3 GB RAM Windows Vista/7/8/8.1/10/11, USB 2.0 port |
Overall dimensions (W×D×H) | 130 × 212 × 200 mm | 130 × 212 × 200 mm |
Weight | 1.7kg | 2.2 kg |
Input current/power consumption | 12 V DC, 3.3 A / 40 W | 12 V DC, 5 A / 60 W |
External power supply | Input AC 100–240 V 50/60 Hz, Output DC 12 V | Input AC 100–240 V 50/60 Hz, Output DC 12 V |
-
ManufacturerGrant Instruments (Cambridge) Ltd
-
Country of OriginLatvia
-
Temperature Setting Range+25 to 70 (increment 0.1°C), +4 to +70 (increment 0.1°C)
-
Bottom Control Range PointAmbient +5°C, Ambient -15°C
-
Measurement Precision±0.3 OD, Not Applicable
-
Measurement Wavelength (nm)850, Not Applicable
-
Cultural Media Volume (ml)10-30, Not Applicable