Spot the Difference in the SGE Lineup!
The SGE inlet liner range aims to make it simple for all gas chromatographers to select the correct liner. Choosing the right inlet liner and injection parameters can increase peak areas and reduce detection limits by up to 300%.
- Easy to choose - color coded by geometry to simplify your selection.
- Easy to use - contains o-rings so you're ready to go.
- Confidence in your analysis - certified deactivation.
Features and benefits
- Straight liners facilitate higher split flows.
- Narrow bore straight liners facilitate fast GC work.
- Small injection volumes of less than 0.5 µL are best used.
- Narrow bore straight liners improve focusing of gaseous samples (purge, trap and headspace).
- Color coded purple.
Recommended applications
Straight liners are recommended for the following sample or injection modes:
- General purpose.
- Concentrated samples.
- Dirty samples (only if quartz wool is present).
- Gaseous samples.
- Purge and trap.
- Headspace.
- Split/splitless.
Product specifications
Straight liners available for Agilent, PerkinElmer, Shimadzu 2010, 17A, 2014 and 2025 injectors, Thermo Scientific, and Varian/Bruker 1177 and 1078/1079 injectors.
Injector |
Length (mm) |
OD (mm) |
ID (mm) |
Agilent |
78.5 |
6.3 |
4 |
Agilent |
78.5 |
6.3 |
1.2 |
Agilent |
78.5 |
6.3 |
2 |
PerkinElmer |
92 |
6.2 |
4 |
PerkinElmer |
92 |
6.2 |
2 |
PerkinElmer |
86.2 |
4 |
2 |
PerkinElmer |
112 |
6 |
3 |
PerkinElmer |
100 |
5 |
3 |
Shimadzu |
95 |
5 |
2.6 |
Shimadzu |
95 |
5 |
3.4 |
Thermo |
105 |
8 |
3 |
Thermo |
105 |
8 |
5 |
Thermo |
78.5 |
6.3 |
4 |
Varian/Bruker |
78.5 |
6.3 |
4 |
Varian/Bruker |
78.5 |
6.3 |
1.2 |
Varian/Bruker |
54 |
5 |
0.5 |
-
ManufacturerTrajan Scientific Europe Ltd
-
Country of OriginAustralia
-
Length (mm)78.5, 92
-
Internal Diameter (mm)1.2, 2, 4
-
Pack SizeEach, 5, 25
-
TypeStraight Inlet Liner, Straight Inlet Liner, With Quartz Glass, Straight Inlet Liner, With Quartz Wool, OptChem™ Straight Inlet Liner with Pre-Fitted CRS ONE O-Ring
-
Instrument CompatabilityAgilent Intuvo 9000, 8890, 8860, 7890, 7890B, 7820A, 6890, 6850, 5890 and 4890; Bruker/Varian 1177; Lucidity GC-FID; PerkinElmer GC 2400, Clarus 690 and 590; Scion Instruments 8500 and 8300; Thermo Scientific TRACE 1600, 1610, 1300 series and GC Ultra, Agilent 8890, 8860, 7890, 6890, 6850, 5890, 4890 and 7820A, Bruker/Varian 1078, 1079, 1093 and 1094, Dani GC 1000 and Master GC, PerkinElmer Clarus 680, 580, 480 and Autosystem, Shimadzu Nexis GC-2030, GC-2025, GC-2014, GC-2010 Pro and GC-2010, Shimadzu Nexis GC-2030, GC-2010 Pro, GC-2010 and GC-17A