Atago Digital Portable Benchtop Refractometer, Palette Series

Score: 5.00 (votes: 1)
No reviews.
SKU Range Accuracy Model Weight (In Grams) Price (excluding VAT) Availability Qty To Purchase
Atago Digital Portable Benchtop Refractometer, Palette Series 3405 Brix : 0.0 to 32.0% Brix ±0.1% PR-32α 270 £686.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3442 Brix : 0.0 to 45.0% Brix ±0.1% PR-101α 270 £1053.33 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3452 Brix : 0.0 to 60.0% Brix ±0.1% PR-301α 270 £1786.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3462 Brix : 45.0 to 90.0% Brix ±0.1% PR-201α 270 £1511.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3477 Concentration of Isopropyl Alcohol 0.0 to 60.0% (W/W) 0 to 30%:±0.5% PR-60PA 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3480 Refractive Index : 1.3306 to 1.4436 0.0 to 60.0% (W/W) Refractive Index ±0.0002 (water at 20°C) PR-RI 270 £1054.00 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3478 Water Solution of Hydrogen Peroxide 0.0 to 50.0% (W/W) Concentration of Hydrogen Peroxide :±0.5% PR-50HO 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3486 Concentration of Ethyl Alcohol : 0.0 to 45.0%(w/w) Concentration of Ethyl Alcohol :+0.5% (0 to 30%) PET-109 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3464 Urine Specific Gravity. : 1.0000 to 1.0600 Urine Specific Gravity ±0.0010 UG-α 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3488 Concentration of Salinity : 0 to 100‰(w/w) Concentration of Salinity:±2‰ PR-100SA 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3454 Butyro 30.0 to 90.0 and RI 1.4450 to 1.4850 Butyro ±0.5 (at 40℃) RI ±0.0003 (at 40℃) PR-BUTYRO 270 £686.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3489 Concentration of Dimethylformamide : 0.0 to 40.0%(w/w) Concentration of Dimethylformamide :±0.3% PR-40DMF 270 £1191.67 1 + -
Atago Digital Portable Benchtop Refractometer, Palette Series 3415 Brix (determined by ICUMSA) : 0.0 to 45.0% T.A. 1990 (Titre Alcoometrique established in 1990) : 0.0 to 26.0% T.A. 1971 (Titre Alcoometrique established in 1971) : 0.0 to 25.0% Oe (GER) (Oechsle used in Germany) : 0 to 240° Oe (Oechsle) : 0 to 240° KMW (o Brix (determined by ICUMSA) : ± 0.1% T.A. 1990 (Titre Alcoometrique established in 1990) : ± 0.2% T.A. 1971 (Titre Alcoometrique established in 1971) : ± 0.2% Oe (GER) (Oechsle used in Germany) : ± 1° Oe (Oechsle) : ± 1° KMW (or babo) : ± 0.2° Baume : ± 0 WM-7 270 £1191.67 1 + -

 

 

Timeless Quality and Performance IoT Supported With Near Field Communication Technology

This model is suitable for fruits juice, food and beverage as well as chemicals and industrial liquids such as cutting oil, cleaning liquid.The unit is programmed with the user-scale feature which allows to input the coefficient to display the concentrations directly. Also, it is equipped with ELI function for the accurate measurements with confidence even at outside.

In addition to the Bluetooth-enabled refractometers, ATAGO ® released refractometers with near-field communication (NFC) technology for the ease of storing and sharing data with phones, tablets, laptops, and other NFC-equipped devices. Simply by tapping NFC-equipped devices, up to 100 measurement data with the date and time are transferred in a matter of seconds. The NFC solution is simpler and prevents typical human errors in data collection and data generation.

With the ever-evolving movement of profound change in how humans interact with machine automation, this upgrade seizes one’s time to write down measurements with a pen or paper.


The Palette series - digital refractometers, are compact battery-operated instruments that can display the measured values of samples quickly with one touch of the START switch.

 

Brix Models and Specifications

 

 

This model is suitable for fruits juice, food and beverage as well as chemicals and industrial liquids such as cutting oil, cleaning liquid.The unit is programmed with the user-scale feature which allows to input the coefficient to display the concentrations direcly. Also, it is equipped with ELI function for the accurate measurements with confidence even at outside.

This model is suitable for fruits juice, food and beverage as well as chemicals and industrial solutions such as cutting oil, cleaning liquid.The unit is programmed with the user-scale feature which allows to input the coefficient to display the concentrations direcly. Also, it is equipped with ELI function for the accurate measurements with confidence even at outside.

It is suitable for various samples up to Brix 60% including jams, concentrated juices and lubricant.The unit is programmed with the user-scale feature which allows to input the coefficient to display the concentrations direcly. Also, it is equipped with ELI function for the accurate measurements with confidence even at outside.

It is suitable for higher concentration like jellies, raw liquid sugar, etc.The unit is programmed with the user-scale feature which allows to input the coefficient to display the concentrations direcly. Also, it is equipped with ELI function for the accurate measurements with confidence even at outside.

 

PR-32α

PR-101α

PR-201α

PR-301α

Cat.No.

3405

3442

3452

3462

Measurement Range

Brix

0.0 to 32.0%

Brix

0.0 to 45.0%

Brix

0.0 to 60.0%

Brix

45.0 to 90.0%

Minimum Indication

Brix0.1%

Measurement

Accuracy

Brix±0.1%

(5 to 40℃)

Brix±0.1%

(10 to 40℃)

Brix±0.1%

(10 to 30℃)

Measurement

Temperature

5 to 40℃

Automatic Temperature Compensation

10 to 40℃

Automatic Temperature Compensation

Ambient Temperature

5 to 40℃

10 to 40℃

Sample Volume

0.1mL or more

Measurement Time

3 seconds (approximately)

Backlight

The backlight stays on for 30 seconds after any Button is pressed.

Output

NFC Forum Type 4 Tag              ISO/IEC 14443 Type A

Output category : Date Time, Brix [%] or adjusted value, Temp [degC] yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx

(e.g.)2018/08/17␣09:30:45,␣␣12.3,␣␣20.4

Power Supply

006P Alkaline Battery (9V)

International

Protection Class

IP 65 Water Resistant

Dimensions and

Weight

17(W)×9(D)×4(H)cm, 270g

 

Special Scale Models and Specifications

 

The salinity per mill (‰) of seawater can be measured with only a small quantity of sample and with a simple procedure. The temperature is automatically corrected and not necessary to worry about the temperature.

New PR-BUTYRO perfect for Butter, Ghee & Edible Oil industry for checking purity / adulteration. PR-BUTYRO has dual scales of Butyro and Refractive Index.The temperature is automatically corrected and not necessary to worry about the temperature.

The concentration of dimethylformamide used as a solvent for synthetic leather/fiber and gas refinement can be measured with only a small quantity of sample and with a simple procedure.The temperature is automatically corrected and not necessary to worry about the temperature.

The concentration of isopropyl alcohol used for cleaning, wetting in printout and other uses can be measured with only a small quantity of sample and with a simple procedure.The temperature is automatically corrected and not necessary to worry about the temperature.

It is suitable for measuring the refractive indices of liquid samples in pharmaceutical and chemical products.When the start key is pressed after placing some droplets of sample on the prism, the refractive index and temperature will be displayed.

The concentration of a water solution of hydrogen peroxide used as a disinfecting solution for cartons for soft drinks and milk-based drinks can be measured with only a small quantity of sample and with a simple procedure.The temperature is automatically corrected and not necessary to worry about the temperature.

The concentration of ethyl alcohol used for foods, cleaning, cooling and other purposes can be measured with only a small quantity of sample and with a simple procedure.The temperature is automatically corrected and not necessary to worry about the temperature.

This new Digital Urine Specific Gravity Refractometer UG-α (alpha) is an upgraded version of the late UG-1.After pressing the START key, with the sample placed on the prism, the measurement values will be displayed within 3 seconds.

 

PR-100SA

PR-BUTYRO

PR-40DMF

 PR-60PA

PR-RI PR-50HO PET-109 UG-α

 

Measurement range

Concentration of salinity : 0 to 100‰(w/w)

Butyro 30.0 to 90.0 (Automatic Temperature Compensation)
RI 1.4450 to 1.4850
(Converted at 40℃、Automatic Temperature Compensation)

Concentration of dimethylformamide : 0.0 to 40.0%(w/w)

 

Concentration of Isopropyl Alcohol
0.0 to 60.0%(w/w)

Refractive Index
1.3306 to 1.4436 
Concentration of Hydrogen Peroxide 
0.0 to 50.0%(w/w)

Concentration of Ethyl Alcohol
0.0 to 45.0%(w/w)

Urine Specific Gravity
  1.0000 to 1.0600

 

Resolution

Concentration of salinity :1‰   Temperature : 0.1℃

Butyro 0.1 RI 0.0001
Temperature 0.1 ℃

Concentration of dimethylformamide : 0.1%  Temperature : 0.1℃

 

Concentration of Isopropyl Alcohol 0.1%
Temperature : 0.1℃

Refractive Index 0.0001 
Temperature 0.1 ℃ 
Concentration of Hydrogen Peroxide : 0.1% Temperature : 0.1℃ Concentration of Ethyl Alcohol : 0.1 %

Urine Specific Gravity
0.0001

Temperature 0.1℃

 

 

Measurement accuracy

Concentration of salinity:±2‰

Butyro ±0.5 (at 40℃) RI ±0.0003 (at 40℃)
Temperature ±1 ℃

Concentration of dimethylformamide :±0.3%

 

Concentration of Isopropyl Alcohol :±0.5%(0 to 30%)

Accuracy declines gradually after the concentration of 30% is exceeded. Accuracy is, for example, ±0.8% when the concentration is 40%, and ±1.6% at a concentration of 60%.

 Refractive Index ±0.0002 (water at 20 ℃)
Temperature ±1 ℃
Concentration of Hydrogen Peroxide :±0.5% Concentration of ethyl alcohol :+0.5% (0 to 30%)
Accuracy declines gradually after the concentration
of 30% is exceeded. Accuracy is, for example,
+0.8% when the concentration is 40%, and + 1.2%
at a concentration of 45%.
Urine Specific Gravity ±0.0010

 

Measurement temperature range

5 to 40℃ (Automatic Temperature Compensation)

10 to 50 ℃ (Automatic Temperature Compensation)

5 to 40℃ (Automatic Temperature Compensation)

 

10 to 35 ℃ (Automatic Temperature Compensation)

5 to 45℃  5 to 40℃ (Automatic Temperature Compensation) 10 to 35° C (Automatic Temperature Compensation) 10 to 35° C (Automatic Temperature Compensation)

 

Ambient temperature range

5 to 40℃

10 to 40 ℃

5 to 40℃

 

10 to 35℃

10 to 40℃  5 to 40℃ 10 to 35℃ 10 to 35℃

 

Sample volume

0.1mL or more

0.1mL or more

0.1mL or more

 0.1mL or more

0.1mL or more  0.1mL or more   0.1mL or more  0.1mL or more 

 

Measurement time

3 seconds (approximately)

3 seconds (approximately)

3 seconds (approximately)

 3 seconds (approximately)

3 seconds (approximately)  3 seconds (approximately)   3 seconds (approximately)   3 seconds (approximately) 

Backlight

The backlight stays on for 15 seconds after any button is pressed.

The backlight stays on for 15 seconds after any button is pressed

The backlight stays on for 15 seconds after any button is pressed.

The backlight stays on for 15 seconds after any button is pressed.

The backlight stays on for 15 seconds after any button is pressed.  The backlight stays on for 15 seconds after any button is pressed.   The backlight stays on for 15 seconds after any button is pressed. The backlight stays on for 15 seconds after any button is pressed.

 

 

Output

NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: Date Time, Seawater [per mille], Temp [degC]
      yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
    (e.g.)2018/08/17␣09:30:45,␣␣␣␣23,␣␣20.4
NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: Date Time, Butyro, RI, Temp [degC]
  yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
(e.g.)2018/08/17␣09:30:45,32.3 ,1.4532 ,␣␣20.4
 NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: 
Date Time, Dimethylformamide [g/100g], Temp [degC]
  yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
(e.g.)2018/08/17␣09:30:45,␣␣12.3,␣␣20.4

NFC Forum Type 4 Tag      ISO/IEC 14443 Type A Output category:

Date Time, Isopropyl alcohol [g/100g], Temp [degC] yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx (e.g.)2018/08/17␣09:30:45,␣␣12.3,␣␣20.4

 NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: Date Time, RI, Temp [degC]
  yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
(e.g.)2018/08/17␣09:30:45,1.3425,␣␣20.4
 NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: 
Date Time, Hydrogen peroxide [g/100g], Temp [degC]
  yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
(e.g.)2018/08/17␣09:30:45,␣␣12.3,␣␣20.4
  NFC Forum Type 4 Tag   ISO/IEC 14443 Type A
Output category: Date Time, Urine S.G., Temp [degC]
  yyyy/mm/dd␣HH:MM:SS,xxxxxx,xxxxxx
(e.g.)2018/08/17␣09:30:45,1.0356,␣␣20.4

Power supply

006P Alkaline Battery (9V)

006P Alkaline Battery (9V)

006P Alkaline Battery (9V)

 006P Alkaline Battery (9V)

006P Alkaline Battery (9V)  006P Alkaline Battery (9V)   006P Alkaline Battery (9V)  006P Alkaline Battery (9V) 

 

International Protection Class

IP 65

IP 65

IP 65

IP 65

IP 65  IP 65   IP 65   IP 65  

Dimensions & Weight

17(W)×9(D)×4(H)cm, 270g

17(W)×9(D)×4(H)cm, 270g

17(W)×9(D)×4(H)cm, 270g

17(W)×9(D)×4(H)cm, 270g

17(W)×9(D)×4(H)cm, 270g  17(W)×9(D)×4(H)cm, 270g   17(W)×9(D)×4(H)cm, 270g   17(W)×9(D)×4(H)cm, 270g  

 

Applications

Food
Always have a constant taste!

Seasoning / soy sauce / sauce / soy milk / Sauce / jam / honey / bean paste syrup / oil / fat etc.

Beverage
Active in quality stability!!

Fruit drink / soft drink Carbonated drinks

Eating out When stewed To check the end point!

Ramen soup / Mentsuyu Sauce / bowl sauce, etc.

Agriculture
To determine the harvest time!

Fruit / vegetable / leaf juice Stem juice / root juice

Salt
Pickling liquid and seawater For concentration check!


Saline / seawater / pickle preparation liquid 
Metal Processing
Of cutting oil For concentration control!

Chemical Of various solutions For refractive index management!

Cleaning solution / antifreeze solution / brine solution Snow melting agent / cosmetics

Medical
Urine specific gravity, serum protein For inspection!

Urine / serum
※There is also a scale for clinical use.

    • Weight (In Grams)
      270 g
    • SKU
      3405
    • UPC/ISBN
      4560161235933
    • Commodity Codes
      90275000
  • Manufacturer
    Atago Co Ltd
  • Country of Origin
    Japan
  • Range
    Brix : 0.0 to 32.0%, Brix : 0.0 to 45.0%, Brix : 0.0 to 60.0%, Brix : 45.0 to 90.0%, Refractive Index : 1.3306 to 1.4436 0.0 to 60.0% (W/W), Concentration of Isopropyl Alcohol 0.0 to 60.0% (W/W), Water Solution of Hydrogen Peroxide 0.0 to 50.0% (W/W), Urine Specific Gravity. : 1.0000 to 1.0600, Concentration of Ethyl Alcohol : 0.0 to 45.0%(w/w), Concentration of Salinity : 0 to 100‰(w/w), Butyro 30.0 to 90.0 and RI 1.4450 to 1.4850, Concentration of Dimethylformamide : 0.0 to 40.0%(w/w), Brix (determined by ICUMSA) : 0.0 to 45.0% T.A. 1990 (Titre Alcoometrique established in 1990) : 0.0 to 26.0% T.A. 1971 (Titre Alcoometrique established in 1971) : 0.0 to 25.0% Oe (GER) (Oechsle used in Germany) : 0 to 240° Oe (Oechsle) : 0 to 240° KMW (o
  • Accuracy
    Brix ±0.1%, Refractive Index ±0.0002 (water at 20°C), 0 to 30%:±0.5%, Concentration of Hydrogen Peroxide :±0.5%, Urine Specific Gravity ±0.0010, Concentration of Ethyl Alcohol :+0.5% (0 to 30%), Concentration of Salinity:±2‰, Butyro ±0.5 (at 40℃) RI ±0.0003 (at 40℃), Concentration of Dimethylformamide :±0.3%, Brix (determined by ICUMSA) : ± 0.1% T.A. 1990 (Titre Alcoometrique established in 1990) : ± 0.2% T.A. 1971 (Titre Alcoometrique established in 1971) : ± 0.2% Oe (GER) (Oechsle used in Germany) : ± 1° Oe (Oechsle) : ± 1° KMW (or babo) : ± 0.2° Baume : ± 0
  • Model
    PR-32α, PR-101α, PR-201α, PR-301α, PR-RI, PR-60PA, PR-50HO, UG-α, PET-109, PR-100SA, PR-BUTYRO, PR-40DMF, WM-7

Accessories