Mettler Toledo 51343195 pH electrode InLab Mono glass-body, pH electrode
Specifications - pH electrode InLab Mono
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector S7 Type of junction -- Shaft Material Glass Sensor Type Half-cell Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample General Purpose -
Mettler Toledo 51343153 pH electrode InLab Solids combination pH electrode with S7 screw head
Specifications - pH electrode InLab Solids
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Open junction Shaft Material Glass Sensor Type Combined electrode Shaft length 25 mm Shaft Diameter 6 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte XEROLYT® EXTRA Polymer Membrane glass LoT Membrane resistance (25°C) < 250 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample Semi-solid samples -
Mettler Toledo 30248112 pH electrode InLab Pure glass-body, combination pH electrode with S7 screw head
Specifications - pH electrode InLab Pure
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Immovable glass sleeve Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte FRISCOLYT-B® Membrane glass LoT Membrane resistance (25°C) < 50 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Low-ion strength (pure water) Reference electrolyte Order no. 51343185 -
Mettler Toledo 51343157 pH electrode InLab Surface glass-body, combination pH electrode with S7 Screw Head
Specifications - pH electrode InLab Surface
Measuring range pH 1 – 11 Temperature Range 0 °C – 50 °C Connector S7 Type of junction Ceramic ring Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass LoT Membrane resistance (25°C) < 800 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Surface Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343174 pH electrode InLab Cool glass-body, combination pH electrode with S7 screw head
Specifications - pH electrode InLab Cool
Measuring range pH 1 – 11 Temperature Range -30 °C – 80 °C Connector S7 Type of junction Immovable glass sleeve Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte FRISCOLYT-B® Membrane glass LoT Membrane resistance (25°C) < 50 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Cold samples Reference electrolyte Order no. 51343185 -
Mettler Toledo 51343176 pH electrode InLab Hydrofluoric glass-body, combination pH electrode with S7 screw head
Specifications - pH electrode InLab Hydrofluoric
Measuring range pH 1 – 11 Temperature Range 0 °C – 100 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HF Membrane resistance (25°C) < 100 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample HF bearing samples (<1g/L) Reference electrolyte Order no. 51343180 -
Mettler Toledo 30247850 pH Electrode InLab Cool Pro-ISM glass-body, combination pH Electrode with Integrated Temperature Sensor
Specifications - pH Electrode InLab Cool Pro-ISM
Measuring range pH 1 – 11 Temperature Range -30 °C – 80 °C Connector MultiPin™ Type of junction Immovable glass sleeve Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte FRISCOLYT-B® Membrane glass LoT Membrane resistance (25°C) < 50 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample Cold samples Reference electrolyte Order no. 51343185 -
Mettler Toledo 30248826 pH Electrode InLab Reach Pro-225 glass-body, combination pH electrode with Integrated Temperature Probe
Specifications - pH Electrode InLab Reach Pro-225
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 225 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 30249570 pH Electrode InLab Surface Pro-ISM glass-body, combination pH electrode with integrated temperature probe
Specifications - pH Electrode InLab Surface Pro-ISM
Measuring range pH 1 – 11 Temperature Range 0 °C – 50 °C Connector MultiPin™ Type of junction Ceramic ring Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass LoT Membrane resistance (25°C) < 800 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample Surface Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343061 pH electrode InLab Reach Pro-425 glass-body, combination pH electrode with integrated temperature probe
Specifications - pH electrode InLab Reach Pro-425
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 425 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343151 pH electrode InLab Viscous Pro-ISM glass-body, combination pH electrode with integrated temperature probe
Specifications - pH electrode InLab Viscous Pro-ISM
Measuring range pH 0 – 14 Temperature Range 0 °C – 130 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 40 mm Shaft Diameter 6 mm Parameter pH Reference System SteadyForce™ Reference electrolyte FRISCOLYT-C® Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter No Maintenace-free Yes Signal type Analog Sample Emulsion
Viscous samples -
Mettler Toledo 51343156 pH electrode InLab Solids Go-ISM glass-body, combination pH electrode with integrated temperature probe
Specifications - pH electrode InLab Solids Go-ISM
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector BNC/RCA (Cinch) IP67 Type of junction Open junction Shaft Material Glass Sensor Type Combined electrode Shaft length 25 mm Shaft Diameter 6 mm Cable (Length) 1.8 m Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte XEROLYT® EXTRA Polymer Membrane glass LoT Membrane resistance (25°C) < 250 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter Yes Maintenace-free Yes Signal type Analog Sample Semi-solid samples -
Mettler Toledo 51343160 pH electrode InLab Micro glass-body, micro combination pH electrode with S7 screw head
Specifications - pH electrode InLab Micro
Measuring range pH 0 – 14 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 60 mm Shaft Diameter 3 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass U Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Small samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51344072 pH electrode InLab Science Pro-ISM glass-body, combination pH electrode with integrated temperature probe
Specifications - pH electrode InLab Science Pro-ISM
Measuring range pH 0 – 12 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Movable glass sleeve Shaft Material Glass Sensor Type Combined electrode Shaft length 170 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass A41 Membrane resistance (25°C) < 600 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample General Purpose
non-aquous samples
TRIS buffer
waste waterReference electrolyte Order no. 51343180 -
Mettler Toledo 59904572 pH electrode InLab NMR glass-body, micro combination pH electrode with S7 screw head
Specifications - pH electrode InLab NMR
Measuring range pH 0 – 14 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 200 mm Shaft Diameter 3 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass U Membrane resistance (25°C) < 1000 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Small samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51344163 pH electrode InLab Micro Pro-ISM glass-body, micro combination pH electrode with integrated temperature sensor
Specifications - pH electrode InLab Micro Pro-ISM
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 130 mm Shaft Diameter 5 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass U Membrane resistance (25°C) < 300 MΩ ISM Yes Temperature probe NTC 30 kΩ For portable meter No Maintenace-free No Signal type Analog Sample Small samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343164 pH electrode InLab Flex-Micro semi-micro combination pH electrode with a flexible shaft and fixed cable
Specifications - pH electrode InLab Flex-Micro
Measuring range pH 0 – 14 Temperature Range 0 °C – 80 °C Connector BNC Type of junction Porous PTFE Shaft Material Epoxy Sensor Type Combined electrode Shaft length 180 mm Shaft Diameter 6 mm Cable (Length) 1 m Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte Gel Membrane glass U Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample Small samples -
Mettler Toledo 51343165 pH electrode InLab Semi-Micro glass-body, semi-micro combination pH electrode with S7 screw head
Specifications - pH electrode InLab Semi-Micro
Measuring range pH 0 – 12 Temperature Range 0 °C – 100 °C Connector S7 Type of junction Open junction Shaft Material Glass Sensor Type Combined electrode Shaft length 100 mm Shaft Diameter 6 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte XEROLYT® EXTRA Polymer Membrane glass A41 Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample Small samples
Viscous samples -
Mettler Toledo 30248828 pH Electrode InLab Reach Pt1000-225 glass-body, combination pH electrode with integrated Pt1000 temperature probe
Specifications - pH Electrode InLab Reach Pt1000-225
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 225 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe Pt1000 For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343062 pH electrode InLab Reach Pt1000-425 glass-body, combination pH electrode with integrated Pt1000 temperature probe
Specifications - pH electrode InLab Reach Pt1000-425
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector MultiPin™ Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 425 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe Pt1000 For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343150 pH electrode InLab Viscous glass-body, combination pH electrode with SteadyForceTM and S7 Screw Head
Specifications - pH electrode InLab Viscous
Measuring range pH 0 – 14 Temperature Range 0 °C – 130 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 40 mm Shaft Diameter 6 mm Parameter pH Reference System SteadyForce™ Reference electrolyte FRISCOLYT-C® Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample Emulsion
Viscous samples -
Mettler Toledo 59902917 pH electrode InLab Flow glass-body, combination pH electrode with SteadyForceTM and S7 screw head
Specifications - pH electrode InLab Flow
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Double ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 40 mm Shaft Diameter 7 mm Parameter pH Reference System SteadyForce™ Reference electrolyte DPA Gel Membrane glass LoT Membrane resistance (25°C) < 250 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog -
Mettler Toledo 30253098 pH electrode InLab Water Go combination pH electrode with a plastic shaft, ring junction and S7 screw head
Specifications - pH electrode InLab Water Go
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector BNC/RCA (Cinch) IP67 Type of junction Porous PTFE Shaft Material PSU Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Cable (Length) 1.8 m Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass LoT Membrane resistance (25°C) < 150 MΩ ISM No Temperature probe NTC 30 kΩ For portable meter Yes Maintenace-free No Signal type Analog Sample Low-ion strength (pure water)
waterReference electrolyte Order no. 51343180 -
Mettler Toledo 51343070 pH electrode InLab Science glass-body, combination pH electrode with S7 screw head and movable glass sleeve junction
Specifications - pH electrode InLab Science
Measuring range pH 0 – 12 Temperature Range 0 °C – 100 °C Connector S7 Type of junction Movable glass sleeve Shaft Material Glass Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass A41 Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample General Purpose
TRIS buffer
waste waterReference electrolyte Order no. 51343180 -
WTW 103732 SenTix RJD pH Electrode with Polymer Electrolyte
pH electrode, NTC 30 kOhm, polymer electrolyte, split ring junction, glas shaft, 1 m fixed cabel with DIN plug and 4 mm banana plug.
-
WTW 103762 SenTix 980-P IDS Precision pH Electrode
IDS pH combination electrode with liquid electrolyte (3 mol/l KCl), glass shaft and integrated temperature sensor. QSC function. Electrode with plug head for AS IDS/1.5 cable or wireless module.
-
Mettler Toledo 30244733 pH Electrode InLab Reach 225 glass-body, Combination pH Electrode with S7 Screw Head and 225 mm Long Shaft
Specifications - pH electrode InLab Reach 225
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 225 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 30248120 pH Electrode InLab Reach 425 glass-body, combination pH electrode with S7 Screw Head and 425 mm Long Shaft
Specifications - pH Electrode InLab Reach 425
Measuring range pH 0 – 14 Temperature Range 0 °C – 100 °C Connector S7 Type of junction Ceramic Shaft Material Glass Sensor Type Combined electrode Shaft length 425 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass HA Membrane resistance (25°C) < 600 MΩ ISM No Temperature probe No For portable meter No Maintenace-free No Signal type Analog Sample Large samples Reference electrolyte Order no. 51343180 -
Mettler Toledo 51343196 pH electrode InLab Mono Plus glass-body
Specifications - pH electrode InLab Mono Plus
Measuring range pH 0 – 12 Temperature Range 0 °C – 130 °C Connector S7 Type of junction -- Shaft Material Glass Sensor Type Half-cell Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Membrane glass A41 (thick-walled glass) Membrane resistance (25°C) < 700 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample hot samples -
WTW 103731 SenTix HWD pH Electrode with Split Ring Junction
pH-electrode, NTC 30 kOhm, split ring junction, liquid electrolyte (3 mol/l KCl), 1 m fixed cable with DIN plug and 4 mm banana plug.
306 products found