Julabo 9021709 DYNEO DD-1001F-BF DYNEO DD Beer Forcing Test Refrigerated-Heating Circulating Bath
- Superseded model 9162638 F38-ME
Specifications
Dimensions and volumes Dimensions
(W × L × H)45 x 64 x 95 cm Filling volume 42 ... 56 l Weight 73.7 kg Pump connections M16x1 male Barbed fittings inner diameter 8/12 mm Temperature values Working temperature range -38 ... +100 °C Temperature stability ±0.01 °C Setting the resolution of the temperature display 0.01 °C Ambient temperature +5 ... +40 °C Performance values Heating capacity 2 kW Cooling capacity
(Medium: Ethanol)°C kW 20 10 0 -10 -20 -30 1 0.95 0.85 0.6 0.32 0.12 Pump capacity flow rate 8 ... 27 l/min Pump capacity flow pressure 0.1 ... 0.7 bar Viscosity max. 50 cST Refrigerant stage 1
Refrigerant R449A Global Warming Potential for R449A 1397 Filling volume 170 g Carbon dioxide equivalent 0.237 t Bath Bath tank Stainless steel Bath cover integrated Usable bath opening
(W x L / D)35 x 41 / 30 cm Cooling Cooling of compressor 1-stage Air Other Classification
according to DIN12876-1Classification III (FL) Pump function Pressure Pump Pump type Immersion Pump Electronics External pt100 sensor connection integrated Integrated programmer 8x60 steps Temperature control PID2 Absolute temperature calibration 3 Point Calibration Temperature display 3.5" TFT Display Temperature setting Shaft Encoder Electronic Timer
hr:min99 ... 59 Included in delivery Stainless steel insert basket for 20 x 0.5 liter bottles Plexiglass bath cover. -
Julabo 9162640 FP40-ME Refrigerated/Heating Circulator, -40 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9162640 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -40 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.68 0.5 0.32 0.04 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 263 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.031 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 37 x 46 x 69 Weight (kg) 48 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/13 Additional voltage versions available JULABO Refrigerated and Heating Circulators are suitable for temperature application to external systems with simultaneous operation in the bath tank. Models in different performance classes are available. The units provide high heating/cooling capacities to ensure rapid heat-up and cool-down times. With ‚Active Cooling Control' to +200 °C (not on ED models). ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Convenient cleaning of dust by removable venting grid. Some models have a handle or castors to allow easy transport. All models provide a drain port on the front for conveniently draining the bath fluid. Typical applications: Temperature applications to external, closed systems, such as for example photometers, refractometers, viscometers, etc. For simultaneous application to small objects in the circulator bath.
-
Julabo 9153632 F32-MA Refrigerated/Heating Circulator, -35 ... +200°C Working Temperature Range, 8 Litre Capacity
Technical Data
Order No. 9153632 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.39 0.15 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant stage 1 R134a Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 64 Weight (kg) 37 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available -
Julabo 9162632 F32-ME Refrigerated/Heating Circulator, -35 ... +200°C Working Temperature Range, 8 Litre Capacity
Technical Data
Order No. 9162632 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.39 0.15 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 166 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.237 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 64 Weight (kg) 37 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available -
Julabo 9153633 F33-MA Refrigerated/Heating Circulator, -30 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9153633 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.5 0.32 0.12 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 145 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.207 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 69 Weight (kg) 44 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162633 F33-ME Refrigerated/Heating Circulator, -30 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9162633 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.5 0.32 0.12 0.05 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 145 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.207 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 69 Weight (kg) 44 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9153634 F34-MA Refrigerated/Heating Circulator, -30 ... +150°C Working Temperature Range, 20 Litre Capacity
Technical Data
Order No. 9153634 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +150 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.32 0.14 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 24 x 30 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 20 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 38 x 58 x 62 Weight (kg) 42 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162634 F34-ME Refrigerated/Heating Circulator, -30 ... +150°C Working Temperature Range, 20 Litre Capacity
Technical Data
Order No. 9162634 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +150 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.32 0.14 0.03 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 24 x 30 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 20 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 38 x 58 x 62 Weight (kg) 42 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air -
Julabo 9153640 FP40-MA Refrigerated/Heating Circulator, -40 ... +200°C Working Temperature Range, 16 Litre Capacity
Technical Data
Order No. 9153640 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -40 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.68 0.5 0.32 0.04 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 16 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 263 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.031 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 37 x 46 x 69 Weight (kg) 48 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/13 Additional voltage versions available -
Julabo 9162650 FP50-ME Refrigerated/Heating Circulator, -50 ... +200°C Working Temperature Range, 8 Litre Capacity
Technical Data
Order No. 9162650 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.9 0.8 0.5 0.16 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 385 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.51 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 70 Weight (kg) 55 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9162651 FPW50-ME Refrigerated/Heating Circulator, -50 ... +200°C Working Temperature Range, 8 Litre Capacity
Technical Data
Order No. 9162651 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.9 0.8 0.5 0.16 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 480 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.883 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 70 Weight (kg) 55 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Water Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9212632 F32-HE Refrigerated/Heating Circulator, -35 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9212632 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.39 0.15 0.06 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 166 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.237 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 66 Weight (kg) 38 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50-60/12 Additional voltage versions available -
Julabo 9312632 F32-HL Refrigerated/Heating Circulator, -35 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9312632 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.39 0.15 0.06 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 166 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.237 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 66 Weight (kg) 38 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50-60/12 Additional voltage versions available -
Julabo 9312633 F33-HL Refrigerated/Heating Circulator, -30 ... +200°C, Working Temperature Range, 16 Litres Capacity
Technical Data
Order No. 9312633 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.5 0.32 0.12 0.03 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 16 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 145 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.207 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 71 Weight (kg) 45 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9212634 F34-HE Refrigerated/Heating Circulator, -30 ... +150°C, Working Temperature Range, 20 Litres Capacity
Technical Data
Order No. 9212634 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -30 ... +150 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.32 0.14 0.03 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 24 x 30 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 20 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 38 x 58 x 64 Weight (kg) 44 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9212640 FP40-HE Refrigerated/Heating Circulator, -40 ... +200°C, Working Temperature Range, 16 Litres Capacity
Technical Data
Order No. 9212640 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -40 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 -40 kW 0.68 0.5 0.32 0.17 0.04 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 16 Refrigerant stage 2 R404A Filling volume refrigerant stage 2 (g) 263 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 2 (t) 1.031 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 37 x 46 x 71 Weight (kg) 49 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/13 Additional voltage versions available -
Julabo 9312640 FP40-HL Refrigerated/Heating Circulator, -40 ... +200°C, Working Temperature Range, 16 Litres Capacity
Technical Data
Order No. 9312640 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -40 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 -40 kW 0.68 0.5 0.32 0.17 0.04 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 23 x 14 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 16 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 263 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.031 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 37 x 46 x 71 Weight (kg) 49 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/13 Additional voltage versions available -
Julabo 9212650 FP50-HE Refrigerated/Heating Circulator, -50 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9212650 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.9 0.8 0.5 0.16 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 385 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.51 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 72 Weight (kg) 57 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9312650 FP50-HL Refrigerated/Heating Circulator, -50 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9312650 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 -40 kW 0.9 0.8 0.5 0.32 0.16 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 385 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.51 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 72 Weight (kg) 57 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9212651 FPW50-HE Refrigerated/Heating Circulator, -50 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9212651 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 0.9 0.8 0.5 0.16 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 480 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.883 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 72 Weight (kg) 57 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Water Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9312651 FPW50-HL Refrigerated/Heating Circulator, -50 ... +200°C, Working Temperature Range, 8 Litres Capacity
Technical Data
Order No. 9312651 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -50 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 -40 kW 0.9 0.8 0.5 0.32 0.16 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 Refrigerant stage 1 R404A Filling volume refrigerant stage 1 (g) 480 Global Warming Potential for R404A 3922 Carbon dioxide equivalent stage 1 (t) 1.883 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 49 x 72 Weight (kg) 57 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Water Power requirement V / Hz / A 230/50/14 Additional voltage versions available -
Julabo 9153625 F25-MA Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9153625 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 61 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9162625 F25-ME Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9162625 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 61 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50-60/13 Additional voltage versions available -
Julabo 9162626 F26-ME Refrigerated/Heating Circulator, -28 ... +200°C Working Temperature Range, 4.5 Litre Capacity
Technical Data
Order No. 9162626 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control PID, cascade Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 42 x 42 Weight (kg) 31 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9153618 FP35-MA Refrigerated/Heating Circulator, -35 ... +150°C Working Temperature Range, 2.5 Litre Capacity
Technical Data
Order No. 9153618 Model series TopTech Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +150 Temperature control PID Temperature stability (°C) ±0.02 Setting / display resolution 0.01 (-9.99...99.99) / 0.1 °C Temperature Display LED Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 -30 kW 0.45 0.34 0.15 0.05 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 18 x 12 / -- Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 2.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 190 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.272 Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 31 x 42 x 64 Weight (kg) 37 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9212625 F25-HE Refrigerated/Heating Circulator, -28 ... +200°C, Working Temperature Range, 4.5 Litres Capacity
Technical Data
Order No. 9212625 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 64 Weight (kg) 32 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9312625 F25-HL Refrigerated/Heating Circulator, -28 ... +200°C, Working Temperature Range, 4.5 Litres Capacity
Technical Data
Order No. 9312625 Model series HighTech Category Refrigerated - Heating Circulators Working temperature range (°C) -28 ... +200 Temperature control ICC Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 0 -20 kW 0.26 0.2 0.06 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 12 x 14 / 14 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 4.5 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 84 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.12 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 42 x 64 Weight (kg) 32 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air Power requirement V / Hz / A 230/50/12 Additional voltage versions available -
Julabo 9312618 FP35-HL Refrigerated/Heating Circulator, -35 ... +150°C, Working Temperature Range, 2.5 Litres Capacity
Technical Specifications
Dimensions and volumes Dimensions
(W × L × H)31 x 42 x 66 cm Filling volume 2.5 l Weight 38 kg Pump connections M16x1 male Barbed fittings inner diameter 8/12 mm Temperature values Working temperature range -35 ... +150 °C Temperature stability ±0.01 °C Setting the resolution of the temperature display 0.01 °C Temperature display resolution 0.01 °C Ambient temperature +5.0 ... +40.0 °C Performance values Heating capacity 2 kW Cooling capacity
(Medium: Ethanol)°C kW 20 0 -20 -30 0.45 0.34 0.15 0.05 Pump capacity flow rate 22 ... 26 l/min Pump capacity flow pressure 0.4 ... 0.7 bar Maximum suction 0.2 ... 0.4 bar Viscosity max. 70 cST Refrigerant stage 1
Refrigerant R134a Global Warming Potential for R134a 1430 Filling volume 190 g Carbon dioxide equivalent 0.272 t Bath Bath cover integrated Usable bath opening
(W x L / D)18 x 12 / cm Cooling Cooling of compressor 1-stage Air Other Classification
according to DIN12876-1Classification III (FL) IP Code
according to IEC 60529IP 21 Pump type Immersion Pump Electronics Digital interface Profibus optional External pt100 sensor connection integrated Integrated programmer 6x60 steps Temperature control ICC Absolute temperature calibration 3 Point Calibration Temperature display VFD Temperature setting Keypad Included in delivery 2 Barbed fittings for tubing 8 and 12 mm ID. (Pump connections M16x1 male) -
Julabo 9021701 DYNEO DD-200F Refrigerated/Heating Circulator, Working Temperature Range -20 ... +200 °C, 3 ... 4 Filling Volume Litres
Technical Data
Order No. 9021701 Order No. with RS232 Option 9021701.D Order No. with analog Option 9021701.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -20 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 200 20 10 0 -10 -20 kW 0.2 0.2 0.17 0.15 0.1 0.02 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Bath opening / bath depth (W x L / D cm) 13 x 15 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 3 ... 4 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 70 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.1 Digital interfaces USB Analog connection input / output Optional Ambient temperature 5...40 °C Dimensions W x L x H (cm) 23 x 39 x 65 Weight (kg) 25.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9021702 DYNEO DD-201F Refrigerated/Heating Circulator, Working Temperature Range -20 ... +200 °C, 3 ... 4 Filling Volume Litres
Technical Data
Order No. 9021702 Order No. with RS232 Option 9021702.D Order No. with analog Option 9021702.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -20 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 200 20 10 0 -10 -20 kW 0.2 0.2 0.17 0.15 0.1 0.02 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Bath opening / bath depth (W x L / D cm) 13 x 15 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 3 ... 4 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 70 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.1 Ambient temperature 5...40 °C Dimensions W x L x H (cm) 44 x 41 x 44 Weight (kg) 24.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9021703 DYNEO DD-300F Refrigerated/Heating Circulator, Working Temperature Range -20 ... +200 °C, 3 ... 4 Filling Volume Litres
Technical Data
Order No. 9021703 Order No. with RS232 Option 9021703.D Order No. with analog Option 9021703.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -25 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 10 0 -10 -20 kW 0.3 0.3 0.27 0.19 0.08 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Bath opening / bath depth (W x L / D cm) 13 x 15 / 15 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 3 ... 4 Refrigerant stage 1 R134a Filling volume refrigerant stage 1 (g) 100 Global Warming Potential for R134a 1430 Carbon dioxide equivalent stage 1 (t) 0.143 Digital interfaces USB Analog connection input / output Optional Ambient temperature 5...40 °C Dimensions W x L x H (cm) 24 x 42 x 66 Weight (kg) 27.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9021705 DYNEO DD-601F Refrigerated/Heating Circulator, Working Temperature Range -35 ... +200 °C, 8..10 Filling Volume Litres
Technical Data
Order No. 9021705 Order No. with RS232 Option 9021705.D Order No. with analog Option 9021705.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -35 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 200 20 10 0 -10 -20 -30 kW 0.6 0.6 0.54 0.5 0.33 0.19 0.07 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Bath opening / bath depth (W x L / D cm) 22 x 15 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 8 ... 10 Refrigerant stage 1 R452A Filling volume refrigerant stage 1 (g) 150 Global Warming Potential for R452A 2140 Carbon dioxide equivalent stage 1 (t) 0.321 Digital interfaces USB Analog connection input / output Optional Ambient temperature 5...40 °C Dimensions W x L x H (cm) 36 x 46 x 74 Weight (kg) 38.2 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9021706 DYNEO DD-900F Refrigerated/Heating Circulator, Working Temperature Range -38 ... +200 °C, 21..30 Filling Volume Litres
Technical Data
Order No. 9021706 Order No. with RS232 Option 9021706.D Order No. with analog Option 9021706.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -38 ... +200 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 10 0 -10 -20 -30 kW 0.9 0.85 0.8 0.52 0.31 0.11 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Bath opening / bath depth (W x L / D cm) 26 x 35 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 21 ... 30 Refrigerant stage 1 R452A Filling volume refrigerant stage 1 (g) 220 Global Warming Potential for R452A 2140 Carbon dioxide equivalent stage 1 (t) 0.471 Refrigerant stage 2 R452A Digital interfaces USB Analog connection input / output Optional Ambient temperature 5...40 °C Dimensions W x L x H (cm) 39 x 62 x 75 Weight (kg) 51.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9021708 DYNEO DD-1001F Refrigerated/Heating Circulator, Working Temperature Range -38 ... +100 °C, 42...56 Filling Volume Litres
Technical Data
Order No. 9021708 Order No. with RS232 Option 9021708.D Order No. with analog Option 9021708.A Model series DYNEO Category Refrigerated - Heating Circulators Working temperature range (°C) -38 ... +100 Temperature control PID Temperature stability (°C) ±0.01 Setting / display resolution 0.01 °C Temperature Display 3.5" TFT Display Heating capacity (kW) 2 Cooling capacity (Medium Ethanol) °C 20 10 0 -10 -20 -30 kW 1 0.95 0.85 0.6 0.32 0.12 Pump capacity flow rate (l/min) 8 ... 23 Pump capacity flow pressure (bar) 0.1 ... 0.6 Viscosity max. (cSt) 50 Bath opening / bath depth (W x L / D cm) 35 x 41 / 30 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 42 ... 56 Refrigerant stage 1 R452A Filling volume refrigerant stage 1 (g) 170 Global Warming Potential for R452A 2140 Carbon dioxide equivalent stage 1 (t) 0.364 Digital interfaces USB Analog connection input / output Optional Ambient temperature 5...40 °C Dimensions W x L x H (cm) 45 x 64 x 95 Weight (kg) 73.7 Included with each unit 2 each barbed fitting for tubing 8 and 12 mm inner dia. (pump connections M16x1 male) Bath tank Stainless steel Bath cover integrated Cooling of compressor Air -
Julabo 9162670 F70-ME Ultra-Low Refrigerated-Heating Circulators, -70 ... +100 °C, 11-16 Pump capacity flow rate (l/min)
Upper middle class with ext. Pt100 sensor connection
JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.
Technical Data
Order No. 9162670 Model series TopTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -70 ... +100 Temperature stability (°C) ±0.02 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 1.3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60 kW 0.34 0.22 0.17 0.13 0.07 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 12 x 12 / 13 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 4.5 Refrigerant R23, R404A External Pt100 sensor connection integrated Digital interfaces Optional Profibus Ambient temperature 5...40 °C Dimensions W x L x H (cm) 42 x 54 x 71 Weight (kg) 63 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air -
Julabo 9162681 F81-ME Ultra-Low Refrigerated-Heating Circulator, -81 ... +100 °C, 11-16 Pump capacity flow rate (l/min)
Upper middle class with ext. Pt100 sensor connection
JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.
Technical Data
Order No. 9162681 Model series TopTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -81 ... +100 Temperature stability (°C) ±0.02 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 1.3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60 -80 kW 0.45 0.38 0.36 0.32 0.27 0.07 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 13 x 15 / 16 Pump connections M10x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 6.5 Refrigerant R23, R404A External Pt100 sensor connection integrated Digital interfaces Optional Profibus Ambient temperature 5...40 °C Dimensions W x L x H (cm) 50 x 58 x 88 Weight (kg) 86 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air -
Julabo 9162689 FP89-ME Ultra-Low Refrigerated-Heating Circulators, -90 ... +100 °C, 11-16 Pump capacity flow rate (l/min)
Upper middle class with ext. Pt100 sensor connection
Ultra-low Refrigerated Circulator with 2-stage cascade-cooling
JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.
Technical Data
Order No. 9162689 Model series TopTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -90 ... +100 Temperature stability (°C) ±0.02 Setting / display resolution 0.01 °C Integrated programmer 1x10 steps Temperature Display VFD Heating capacity (kW) 1.3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60 -80 kW 1 0.92 0.88 0.75 0.58 0.2 Pump capacity flow rate (l/min) 11-16 Pump capacity flow pressure (bar) 0.23-0.45 Bath opening / bath depth (W x L / D cm) 13 x 15 / 16 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 10 Filling volume (liters) 8 Refrigerant R404A, R508B External Pt100 sensor connection integrated Digital interfaces RS232
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 55 x 60 x 90 Weight (kg) 133 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 barbed fittings suitable for tubing 8 and 10 mm inner dia. (pump connections M10x1 female) Cooling of compressor Air -
Julabo 9312681 F81-HL Ultra-Low Refrigerated-Heating Circulator, -81 ... +100 °C, 22-26 Pump capacity flow rate (l/min)
Technical Data
Order No. 9312681 Model series HighTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -81 ... +100 Temperature stability (°C) ±0.02 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 1.3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60 -80 kW 0.45 0.38 0.36 0.32 0.27 0.07 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 13 x 15 / 16 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 6.5 Refrigerant R23, R404A External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 50 x 58 x 89 Weight (kg) 88 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 female). Cooling of compressor Air JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc.
-
Julabo 9352751 FP51-SL Ultra-Low Refrigerated-Heating Circulator, -51 ... +200°C, 22-26 Pump capacity flow rate (l/min)
Technical Data
Order No. 9352751 Model series HighTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -51 ... +200 Temperature stability (°C) ±0.05 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD , LCD Heating capacity (kW) 3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 kW 2 1.5 1 0.26 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (bar) 0.4-0.7 Pump capacity flow suction (bar) 0.2-0.4 Bath opening / bath depth (W x L / D cm) 18 x 12 / 20 Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume (liters) 11 Refrigerant R507 External Pt100 sensor connection integrated Digital interfaces RS232
RS485
Optional ProfibusAmbient temperature 5...40 °C Dimensions W x L x H (cm) 46 x 55 x 89 Weight (kg) 90 Classification according to DIN12876-1 Classification III (FL) Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia. (pump connections M16x1 male). Cooling of compressor Air JULABO Ultra-Low Refrigerated Circulators for heating and cooling. The units are suitable for external temperature applications with simultaneous operation in the bath tank. The units provide particularly high heating and cooling capacities for rapid heat-up and cool-down times even for large volume, external systems. ‚FP‘ models offer proportional cooling control to ensure energy-saving performance and to reduce heat generation to the environment. Models with the designation ‚W‘ are water-cooled. With handle or castors to allow easy transport. With drain port for conveniently draining the bath fluid. The units offer an improved insulation to prevent ice-formation and have a filling level display. Typical applications: Temperature applications to jacketed reaction vessels, autoclaves, miniplant installations, kilo labs, freezing point determination, calibration at low temperatures, petroleum testing, etc
87 products found
Sort by:
Recommended