Mettler Toledo 51343011 combination pH electrode with plastic shaft, gel electrolyte and fixed cable
Specifications - pH electrode InLab Easy BNC
Measuring range pH 0 – 14 Temperature Range 0 °C – 80 °C Connector BNC Type of junction Ceramic Shaft Material PSU Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Cable (Length) 1.2 m Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte Gel Membrane glass U Membrane resistance (25°C) < 250 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample General Purpose -
WTW 103740 SenTix 940 IDS pH combination electrode with gel electrolyte, plastic shaft and integrated temperature sensor, QSC function, includes 1.5 m fixed cable
Technical Data
SenTix® 940/940-3 950 980 pH 0.000 … 14.000
± 0.0040.000 … 14.000
± 0.0040.000 … 14.000
± 0.004mV – – – Temp. 0 … 80 °C 0 … 80 °C 0 … 100 °C SenTix® 945 Micro 900 Sp-T 900 HW-T-900 Measuring range pH: 0.000 … 14.000 ± 0.002 pH: 0.000 … 14.000 ± 0.002 pH: 2.000 … 13.000 ± 0.002 pH: 0.000 … 14.000 ± 0.002 Area of use 0 … 80 °C 0 … 100 °C 0 … 50 °C 0 … 60 °C Reference electrolyte Gel KCl 3 mol/l Polymer KCl 3 mol/l Membrane form Sphere Cylinder Spear Cylinder Diaphragm 3 x ceramic Platinum wire Hole Grinding Shaft material Glass Glass Plastic Glass Shaft length 120 mm 70/130 mm 65/25 mm 120 mm Shaft diameter 12 mm 12/5 mm 15/5 mm 12 mm Temperature sensor NTC 30 kOhm NTC 30 kOhm NTC 30 kOhm NTC 30 kOhm Connecting cable 1.5 m with digital plug 0.5 m with digital plug 0.5 m with digital plug 0.5 m with digital plug Digital measurement of pH with built-in electrode quality monitoring - usable in all areas of lab and field measurement
- Safely measured values due to signal processing in the sensor
- Easy electrode replacement thanks to calibration data stored inside sensor
- Sensor quality monitoring by QSC function
Full DescriptionWTW SenTix 940 IDS pH combination electrode with gel electrolyte, plastic shaft and integrated temperature sensor, QSC function, includes 1.5 m fixed cable with waterproof digital connector, measuring range pH 0 to 14, temperature 0 to 80 ºC, automatic recognition, memory for 10 calibration records, fail safe signal transfer, low maintenance
-
Mettler Toledo 51343010 combination pH electrode with plastic shaft, gel electrolyte and S7 screw head
Specifications - pH electrode InLab Easy
Measuring range pH 0 – 14 Temperature Range 0 °C – 80 °C Connector S7 Type of junction Ceramic Shaft Material PSU Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte Gel Membrane glass U Membrane resistance (25°C) < 250 MΩ ISM No Temperature probe No For portable meter No Maintenace-free Yes Signal type Analog Sample General Purpose -
WTW 103751 SenTix® Micro 900 -IDS pH combination electrode with 5mm micro head, for measurements in small volumes or vessels, glass shaft, liquid electrolyte, integrated temperature sensor, 1.5m cable with waterproof digital connector, platinum diaphragm
Technical Data
SenTix® 940/940-3 950 980 pH 0.000 … 14.000
± 0.0040.000 … 14.000
± 0.0040.000 … 14.000
± 0.004mV – – – Temp. 0 … 80 °C 0 … 80 °C 0 … 100 °C SenTix® 945 Micro 900 Sp-T 900 HW-T-900 Measuring range pH: 0.000 … 14.000 ± 0.002 pH: 0.000 … 14.000 ± 0.002 pH: 2.000 … 13.000 ± 0.002 pH: 0.000 … 14.000 ± 0.002 Area of use 0 … 80 °C 0 … 100 °C 0 … 50 °C 0 … 60 °C Reference electrolyte Gel KCl 3 mol/l Polymer KCl 3 mol/l Membrane form Sphere Cylinder Spear Cylinder Diaphragm 3 x ceramic Platinum wire Hole Grinding Shaft material Glass Glass Plastic Glass Shaft length 120 mm 70/130 mm 65/25 mm 120 mm Shaft diameter 12 mm 12/5 mm 15/5 mm 12 mm Temperature sensor NTC 30 kOhm NTC 30 kOhm NTC 30 kOhm NTC 30 kOhm Connecting cable 1.5 m with digital plug 0.5 m with digital plug 0.5 m with digital plug 0.5 m with digital plug Digital measurement of pH with built-in electrode quality monitoring - usable in all areas of lab and field measurement
- Safely measured values due to signal processing in the sensor
- Easy electrode replacement thanks to calibration data stored inside sensor
- Sensor quality monitoring by QSC function
Full Description
WTW SenTix® Micro 900 -IDS pH combination electrode with 5mm micro head, for measurements in small volumes or vessels, glass shaft, liquid electrolyte, integrated temperature sensor, 1.5m cable with waterproof digital connector, platinum diaphragm, silver free electrolyte, QSC function, automatic recognition, memory for 10 calibration records, fail safe signal transfer, 70/130(l)x12/5(Ø)mm, measuring range 0-14 pH and 0-100ºC.
-
Mettler Toledo 30253098 pH electrode InLab Water Go combination pH electrode with a plastic shaft, ring junction and S7 screw head
Specifications - pH electrode InLab Water Go
Measuring range pH 1 – 11 Temperature Range 0 °C – 80 °C Connector BNC/RCA (Cinch) IP67 Type of junction Porous PTFE Shaft Material PSU Sensor Type Combined electrode Shaft length 120 mm Shaft Diameter 12 mm Cable (Length) 1.8 m Parameter pH Reference System ARGENTHAL™ with Ag+-trap Reference electrolyte 3 mol/L KCl Membrane glass LoT Membrane resistance (25°C) < 150 MΩ ISM No Temperature probe NTC 30 kΩ For portable meter Yes Maintenace-free No Signal type Analog Sample Low-ion strength (pure water)
waterReference electrolyte Order no. 51343180 -
WTW 103761 SenTix 950-P Robust IDS pH Standard Electrodes
IDS pH combination electrode with liquid (3 mol/l KCl) electrolyte, plastic shaft and integrated temperature sensor. QSC function. Electrode with plug head for AS IDS/1.5 cable or wireless module.