  • WTW 1CA100 Conductivity Benchtop Meter inoLab® Cond 7110, for two and four electrode cells for routine measurements without documentation

    Technical Data

    Values ±1 digit
    Conductivity0 μS/cm … 1000 mS/cm ±0.5 % of value.
    Salinity0.0 … 70.0 (nach IOT)
    0.00 … 20 MOhm cm
    TDS0 … 1999 mg/l
    Temperature-5.0 … 105.0 °C ±0.1 °C
    Reference temperature20/25°C



    • Easy to use
    • Wide range of applications with standard and special measuring cells
    • Suitable for pure water measurements according to pharmacopeia


    Full Description

    inoLab Cond 7110 Easy-to-operate basic conductivity bench-top meter for routine measurement. For AC and battery operation. - Easy handling - Large LCD display - For 2- and 4-electrodes conductivity cells - Automatic Auto Read function - Calibration timer - Smooth, easy-to-c

    Price Upon Application Or Discontinued
  • WTW 1CA101 Conductivity Benchtop Meter inoLab® Cond 7110 SET 1, for two and four electrode cells for routine measurements without documentation , TetraCon® 925 Graphite four electrode measuring cell, 1.5 fixed cable

    Technical Data

    Values ±1 digit
    Conductivity0 μS/cm … 1000 mS/cm ±0.5 % of value.
    Salinity0.0 … 70.0 (nach IOT)
    0.00 … 20 MOhm cm
    TDS0 … 1999 mg/l
    Temperature-5.0 … 105.0 °C ±0.1 °C
    Reference temperature20/25°C



    • Easy to use
    • Wide range of applications with standard and special measuring cells
    • Suitable for pure water measurements according to pharmacopeia


    Full Description

    inoLab Cond 7110 SET 1 Easy-to-operate basic conductivity bench-top meter for routine measurement. For AC and battery operation. Set including conductivity cell. - Easy handling - Large LCD display - For 2- and 4-electrodes conductivity cells - Automatic Auto-read function

    Price Upon Application Or Discontinued
  • Mettler Toledo 30339959 SevenCompact Duo pH/Cond S213-Std-Kit, pH/Conductivity dual channel benchtop meter with InLab Expert Pro-ISM and InLab 731-ISM

    ParameterpH
    Conductivity
    ORP
    ChannelDual-channel
    Version kitReady-to-measure kit
    SensorInLab Expert Pro-ISM
    InLab 731-ISM
    pH measuring range-2 – 20
    pH resolution0.001
    0.01
    0.1
    pH accuracy (±)0.002
    Conductivity measuring range0.001 μS/cm – 1000 mS/cm
    Conductivity resolution0.001 – 1
    Conductivity accuracy (±)0.5 %
    mV measuring range0
    mV resolution0.1
    1
    mV accuracy (±)0.1
    Temperature Range-30 °C – 130 °C
    Temperature resolution0.1 °C
    Temperature accuracy (±)0.1 °C
    PortableNo
    Security and complianceGLP
    Password protection
    User management
    ISM supportYes
    Memory size1.000 measurements
    Data TransferPC
    Printer
    USB stick
    Flexibilty and modularityBarcode reader
    Stirrer
    Protection RatingWatertight and dustproof (IP54)
    • £1750.00
  • WTW 1CA300 Bench-Top Laboratory Conductivity Meter inoLab® Cond 7310 for measurements/documentation according GLP/AQA


    Technical Data

    Conductivity0 μS/cm … 1000 mS/cm ±0.5 % of value
    Salinity0,0 … 70.0 (after IOT
    0.00 … 20 MOhm cm
    TDS1 … 1999 mg/l, 0 to 199.9 g/l
    Specific resistance0.000 Ohm * cm … 199.9 MOhm* cm
    Temperature-5.0 … 105.0 °C ±0.1 °C
    Reference temperature20/25 °C
    Values ±1 digit



    Precise and high performance laboratory conductivity meter with GLP supportung functions for documentation measuring results

    • Convenient and safe operation via plain text menus
    • Documentation of all data via USB interface or optional built-in printer - fast and error-free
    • Suitable for measurements according pharmacopeia


    Full Description

    Precise and convenient conductivity  meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For 2- and 4-electrodes conductivity cells - input for serial


    Price Upon Application Or Discontinued
  • WTW 1CA300P Bench-Top Laboratory Conductivity Meter inoLab® Cond 7310P for measurements/documentation according GLP/AQA with built-in printer


    Technical Data

    Conductivity0 μS/cm … 1000 mS/cm ±0.5 % of value
    Salinity0,0 … 70.0 (after IOT
    0.00 … 20 MOhm cm
    TDS1 … 1999 mg/l, 0 to 199.9 g/l
    Specific resistance0.000 Ohm * cm … 199.9 MOhm* cm
    Temperature-5.0 … 105.0 °C ±0.1 °C
    Reference temperature20/25 °C
    Values ±1 digit



    Precise and high performance laboratory conductivity meter with GLP supportung functions for documentation measuring results

    • Convenient and safe operation via plain text menus
    • Documentation of all data via USB interface or optional built-in printer - fast and error-free
    • Suitable for measurements according pharmacopeia


    Full Description

    Precise and convenient conductivity  meter, menu controlled, for measurements/documentation according GLP/AQA with integrated thermal printer. For AC and battery operation. - Backlit graphic display - Date, time, ID numbers - For 2- and 4-electrodes conductivity cells - input for serial


    Price Upon Application Or Discontinued
  • WTW 1CA301 Bench-Top Laboratory Conductivity Meter inoLab® Cond 7310 SET 1 for measurements/documentation according GLP/AQA with TetraCon® 325 4-electrode conductivity cell with graphite electrodes, integrated temperature sensor, epoxy shaft, 1.5m cable


    Technical Data

    Conductivity0 μS/cm … 1000 mS/cm ±0.5 % of value
    Salinity0,0 … 70.0 (after IOT
    0.00 … 20 MOhm cm
    TDS1 … 1999 mg/l, 0 to 199.9 g/l
    Specific resistance0.000 Ohm * cm … 199.9 MOhm* cm
    Temperature-5.0 … 105.0 °C ±0.1 °C
    Reference temperature20/25 °C
    Values ±1 digit



    Precise and high performance laboratory conductivity meter with GLP supportung functions for documentation measuring results

    • Convenient and safe operation via plain text menus
    • Documentation of all data via USB interface or optional built-in printer - fast and error-free
    • Suitable for measurements according pharmacopeia


    Full Description

    inoLab Cond 7310 SET 1Precise and convenient conductivity  meter, menu controlled, for measurements/documentation according GLP/AQA. For AC and battery operation. Set including conductivity cell. - Backlit graphic display - Date, time, ID numbers


    Price Upon Application Or Discontinued
  • WTW 1FD560 Multi 9620 IDS Multiparameter Benchtop Meter InoLab

    Technical Data

    ParameterpH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels2
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD color graphic
    CMC/QSCYes/Yes
    Data memorymanual 500/10000 automatic
    Analog pH/ORP/ISE sensorsADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Loggermanual/time-controlled
    InterfaceUSB A/Mini USB-B
    PrinterThree pre-installed drivers (description see Operating Instructions)
    Power supplyUniversal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with two inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    •Wireless ready
    •Simultaneous measurement with two independent measuring channels
    •Fatigue proof reading on brilliant color display

    Price Upon Application Or Discontinued
  • WTW 1FD354 inoLab Multi 9310 SET 4 Multiparameter Benchtop Meter

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    •Uncompromised measuring accuracy
    •Wireless ready
    •Digital sensor recognition
    •Smart sensor evaluation

    Price Upon Application Or Discontinued
  • WTW 1FD353 inoLab Multi 9310 SET 3 Multiparameter Benchtop Meter

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    •Uncompromised measuring accuracy
    •Wireless ready
    •Digital sensor recognition
    •Smart sensor evaluation

    Price Upon Application Or Discontinued
  • WTW 1FD56C Inolab Multi 9620 IDS SET C Multiparameter Benchtop Meter

    ParameterpH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels2
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD color graphic
    CMC/QSCYes/Yes
    Data memorymanual 500/10000 automatic
    Analog pH/ORP/ISE sensorsADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Loggermanual/time-controlled
    InterfaceUSB A/Mini USB-B
    PrinterThree pre-installed drivers (description see Operating Instructions)
    Power supplyUniversal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with two inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    •Wireless ready
    •Simultaneous measurement with two independent measuring channels
    •Fatigue proof reading on brilliant color display

    Price Upon Application Or Discontinued
  • Mettler Toledo 30339958 SevenCompact Duo pH/Cond S213-meter, pH/Ion dual channel benchtop meter

    ParameterpH
    Conductivity
    ORP
    ChannelDual-channel
    Version kitMeter only
    pH measuring range-2 – 20
    pH resolution0.001
    0.01
    0.1
    pH accuracy (±)0.002
    Conductivity measuring range0.001 μS/cm – 1000 mS/cm
    Conductivity resolution0.001 – 1
    Conductivity accuracy (±)0.5 %
    mV measuring range0
    mV resolution0.1
    1
    mV accuracy (±)0.1
    Temperature Range-30 °C – 130 °C
    Temperature resolution0.1 °C
    Temperature accuracy (±)0.1 °C
    PortableNo
    Security and complianceGLP
    Password protection
    User management
    ISM supportYes
    Memory size1.000 measurements
    Data TransferPC
    Printer
    USB stick
    Flexibilty and modularityBarcode reader
    Stirrer
    Protection RatingWatertight and dustproof (IP54)
    • £1310.00
  • WTW 1FD350 Multi-Parameter Benchtop Meter inoLab® Multi 9310 IDS for pH, ORP, dissolved oxygen and conductivity

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters - Universal application. 

    Price Upon Application Or Discontinued
  • WTW 1FD570 Multi-Parameter Benchtop Meter inoLab® Multi 9630 IDS or IDS sensors, for measurements/documentation according GLP/AQA


    Technical Data

    Parameter
    pH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels
    3
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD color graphic
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/10000 automatic
    Analog pH/ORP/ISE sensors
    ADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Logger
    manual/timer-controlled
    Interface
    USB A/Mini USB-B
    Printer
    Three preinstalled drivers (description see Operating Instructions)
    Power supply
    Universal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with three inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    • Wireless ready
    • Simultaneous measurement with three independent measuring channels
    • Fatigue proof reading on brilliant color display


    Full Description

    Inolab Multi 9630 IDS - Wirelesss ready professional digital multi-parameter benchtop meter for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen and conductivity. Meter including universal power supply, stand, operation manual, software and USB cable.

    Price Upon Application Or Discontinued
  • WTW 1FD35C inoLab Multi 9310 SET C Multi Parameter Benchtop Meter for pH, ORP, Dissolved Oxygen and Conductivity

    Specifications

    Measuring channel1 (universal)
    ParameterpH, ORP, dissolved oxygen, conductivity
    Measuring rangeDepends on the IDS sensor used
    DisplayLCD graphic, backlit
    CMC/QSCYes/Yes
    Data memorymanual 500/4500 automatic
    Loggermanual/timer-controlled
    InterfaceMini USB-B
    Printer (optional)Thermal printer, width 58 mm
    Power supplyUniversal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries
    • £1520.56
  • WTW 1FD350P Multi-Parameter Benchtop Meter inoLab® Multi 9310P IDS for pH, ORP, dissolved oxygen and conductivity , with built-in printer

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    ionlab Multi 9310P Digital multi-parameter bench-top for IDS sensors with integrated printer for measurements/documentation according GLP/AQA, with integrated thermal printer. Single channel input. - Back-lit graphic display - Automatic recognition of IDS sensors.

    Price Upon Application Or Discontinued
  • Mettler Toledo 30339980 SevenCompact Duo pH/Cond S213-Water Kit, pH/Ion dual channel benchtop meter with InLab Routine Pro-ISM and InLab 741-ISM

    ParameterpH
    Conductivity
    ORP
    ChannelDual-channel
    Version kitReady-to-measure kit
    SensorInLab Pure Pro-ISM
    InLab 741-ISM
    pH measuring range-2 – 20
    pH resolution0.001
    0.01
    0.1
    pH accuracy (±)0.002
    Conductivity measuring range0.001 μS/cm – 1000 mS/cm
    Conductivity resolution0.001 – 1
    Conductivity accuracy (±)0.5 %
    mV measuring range0
    mV resolution0.1
    1
    mV accuracy (±)0.1
    Temperature Range-30 °C – 130 °C
    Temperature resolution0.1 °C
    Temperature accuracy (±)0.1 °C
    PortableNo
    Security and complianceGLP
    Password protection
    User management
    ISM supportYes
    Memory size1.000 measurements
    Data TransferPC
    Printer
    USB stick
    Flexibilty and modularityBarcode reader
    Stirrer
    Protection RatingWatertight and dustproof (IP54)
    • £1990.00
  • WTW 1FD351 Multi-Parameter Benchtop Meter inoLab® Multi 9310 SET 1 IDS for pH, ORP, dissolved oxygen and conductivity with SenTix® 940-3 Low-maintenance IDS pH gel electrode, 3 m fixed cable

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 SET 1 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Set including IDS sensor. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters

    Price Upon Application Or Discontinued
  • WTW 1FD352 Multi-Parameter Benchtop Meter inoLab® Multi 9310 SET 2 IDS for pH, ORP, dissolved oxygen and conductivity with 103780 SenTix® 980 IDS electrode with 3 mol/l KCl, glass shaft, platinum diaphragm

    inoLab® benchtop devices offer the correct solution for pH, ORP, dissolved oxygen and conductivity measurements in the lab

    • Uncompromised measuring accuracy
    • Wireless ready
    • Digital sensor recognition
    • Smart sensor evaluation

     

    Technical Data

    Measuring channel
    1 (universal)
    Parameter
    pH, ORP, dissolved oxygen, conductivity
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD graphic, backlit
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/4500 automatic
    Logger
    manual/timer-controlled
    Interface
    Mini USB-B
    Printer (optional)
    Thermal printer, width 58 mm
    Power supply
    Universal power supply, 100 to 240 V, 50/60 Hz, 4 x 1.5 V AA or 4 x 1.2 V NiMH batteries


    Full Description

    inolab Multi 9310 SET 1 Digital multi-parameter bench-top meter for IDS sensors, for measurements/documentation according GLP/AQA. Set including IDS sensor. Single digital input. - Back-lit graphic display - Automatic recognition of IDS sensors - Documentation of sensor parameters

    Price Upon Application Or Discontinued
  • WTW 1FD57K Multi-Parameter Benchtop Meter inoLab® Multi 9630 IDS SET K in set with IDS sensors: digital IDS pH electrode SenTix® 980, buffer 4, 7 and 10.01, 3 mol/l KCl, optical IDS D.O. sensor FDO 925, digital IDS cond cell TetraCon® 925, 0.01 mol/l KCl


    Technical Data

    Parameter
    pH, mV, ISE, saturation, concentration, partial pressure, conductivity, spec. resistance, salinity, TDS, temperature
    Universal measuring channels
    3
    Measuring range
    Depends on the IDS sensor used
    Display
    LCD color graphic
    CMC/QSC
    Yes/Yes
    Data memory
    manual 500/10000 automatic
    Analog pH/ORP/ISE sensors
    ADA 94 pH/IDS DIN or ADA 94 pH/IDS BNC
    Logger
    manual/timer-controlled
    Interface
    USB A/Mini USB-B
    Printer
    Three preinstalled drivers (description see Operating Instructions)
    Power supply
    Universal power supply 100 to 240 V, 50/60 Hz


    Digital high performance multi-parameter device with three inputs for pH, ISE, conductivity and dissolved oxygen and comprehensive GLP functions

    • Wireless ready
    • Simultaneous measurement with three independent measuring channels
    • Fatigue proof reading on brilliant color display


    Full Description

    Inolab Multi 9630 IDS SET K- Wirelesss ready professional digital multi-parameter benchtop meter for IDS sensors, for measurements/documentation according GLP/AQA. With three universal inputs for pH/mV/ISE, dissolved oxygen and conductivity. Meter including universal power supply, stand, operation manual, software and USB cable plus probes optical dissolved oxygen (FDO 925), 4-electrode conductivity cell (TetraCon 925) and pH electrode (SenTix 980)

    Price Upon Application Or Discontinued
  • WTW 108144 IDS WLM Kit IDS Wireless Modules

    Kit consisting of one of each IDS WLM-S, IDS WLM-M and WLM Charger including USB power supply for wireless operation of IDS plug head sensors. 

    • £363.24