WTW 600325 Turb 430 T, Portable Turbidity Meter for Nephelometric Measurement

Not rated yet

Specifications

MethodNephelometrisch (90° Straylight)
Light SourceTungsten
acc. to Standard MethodUS-EPA 180.1
Measuring Range0-1100 FNU/NTU
Resolution0,01 for 0,00 -9,99
 0,1 for 10 – 99,90
 1 for 100 - 1100
Accuracy0.01 NTU or +/- 2% of meas.value
Reproducability< 0.5%
CalibrationAutomatic, 3 Point
Calibration Protocolyes
Calibration Intervalyes
Data Storage1000 values
Response TimeCa. 3 s
Cuvette28 x 60 mm, 20 ml Sample Volume
Ident Numberyes
Firmware-Updateyes
InterfaceRS 232, USB via Adapter (optional)
Operation Temp.0... +50°C
Power Supply4 Mignon (AA) > 3000 Measurements
Rech.Batt.optional
Data Management GLP compliantoptional PC software LSdata
LabStation+ PC-Software LSdataoptional as small benchtop solution
  • £1584.81
In Stock:  
  • Portable turbidimeter (90°, tungsten) acc. US EPA 180.1 incl. calibration standard kit (0,02-10-1000 NTU) and accessories: 5 empty cuvette (28mm), claening tissues, batt. Optional: LabStation LS Flex/430 with software package LS Flex/430 for GLP-compliant data export (order no. 251301) or rechargeable batteries RB Flex/430 (order no. 251300), PC software LS Flex/430 (standalone order no. 902762)


Turbidity measurement acc. to US EPA 180.1 for any demand up tp 1100 NTU with lab option
Turb® 430 T meet the requirements of nephelometric measurement at 90° stray light for drinking water with highest precision particularly suitable in the range < 1 NTU and is therefore suitable for water analysis,control, such, fuel, cell cultures, food and beverage industries and (health) administration surveillance.

  • Measuring range comprises 0.02 -1100 NTU/FNU with automatic measuring range switching
  • AQA: Calibration interval setting and GLP-compliant documentation
  • Stray light behavior according to pharmacopoeia 5.0
  • Higly precise 

AMCO Clear® Standards


The measurement and automatic 3-point calibration runs menu-guided. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata . The quality assurance of the measured results is supported by calibration interval setting with documentation. This makes Turb® 430 not only a portable meter – also available in a practical field set - but also a precise and reliable benchtop meter for applications of up to 1100 NTU/FNU with optimized data administration!



AMCO Clear® standards

Polymer calibration standards resist against Formazine by significantly higher accuracy and stability without drifting, which increases the measuring accuracy significantly:

  • Manufacturing tolerance of only ±1% for highest result accuracy
  • Long-term stable particle distribution and size
  • No health hazard
  • Easy to dispose of
  • N.I.S.T. traceability 
    • SKU
      600325
    • Commodity Codes
      90275000
  • Manufacturer
    WTW - Xylem Inc
  • Country of Origin
    Germany