- for nephelometric measurement (90°) acc. DIN EN 27027, incl. calibration standard kit (0.02 - 10 - 1000 NTU/FNU), 5 empty cuvette, tissues, batt. (4 AA Mignon), suitable for drinking water. Optional: LabStation LS Flex/430 with software package LSdata Flex/430 for GLP-compliant data export and rech.batt. RB Flex/430 (order no. 251 301) or rechargeable batteries RB Flex/430 (order no. 251 300, PC software LSdata Flex/430 (stand alone 902762).
The turbidity meters Turb® 430 IR acc. to DIN ISO 27027 and Turb® 430 T acc. to US EPA 180.1 meet the requirements of the nephelometric measurement at 90° stray light for drinking water with highest precision, especially in the range < 1 NTU. The measuring range comprises 0-1100 NTU/FNU with automatic measuring range switching and is therefore suitable for water analysis as well as quality control, such as gasoline, cell cultures, as well as in the food and beverage industries.
The measurement and automatic 3-point calibration runs self-explanatory and menu-controlled. The calibration takes place via an AMCO Clear® standard set (0.02-10-1000 NTU). Up to 1000 data sets including sample ID numbers can be stored and later put out GLP-compliant via the PC software LSdata . The quality assurance of the measured results is supported by calibration interval setting with documentation. This makes Turb® 430 not only a portable meter – also available in a practical field set - but also a precise and reliable benchtop meter for applications of up to 1100 NTU/FNU with optimized data administration!
Turb® 430 IR and Turb® 430 T with Labstation – Lab solution up to 1100 NTU/FNU:
- High quality lab precision
- Turbidity measurement in drinking water according to DIN ISO 27027 and US EPA 180.1.
- GLP-compliant data management via optional software LSData
- Optional Lab Station for easy handling incluing LSData
AQA Analytical Quality Assurance is supported by:
- Calibration interval setting
- Calibration protocol
- Stable, highly precise and retraceable AMCO Clear® standards
AMCO Clear® standards
Polymer calibration standards resist against Formazine by significantly higher accuracy and stability without drifting, which increases the measuring accuracy significantly:
- Manufacturing tolerance of only ±1% for highest result accuracy
- Long-term stable particle distribution and size
- No health hazard
- Easy to dispose of
- N.I.S.T. traceability
Specifications
Light source | LED |
pH measurement | yes |
Turbidity measurement | yes |
Calibration interval/record | yes |
Cal. adjustment for selected programs | no |
Special methods with pH and Temp. | yes |
User-defined progr. via LSdata Software | 100 |
Data storage | 1000 |
Sets | available |
Rechargeable batteries w. universal plug | optional |
Methods/programs | ca. 200 |
Cells / Cuvettes: round | 16 mm ( H:91-104 mm); 28 mm |
Ident number | yes |
Interface | RS232 |
PC-Connection | yes |
Method-update via Internet | yes |
Firmware-update via Internet | yes |
LabStation for lab use incl. rechargeable battery + PC Software LSdata | optional |
LSdata Stand alone optional | optional |
Certificates | CE/ETLus/cETL |
Waterproof housing | IP 67 |