SKU Scale Method Model Range Weight (In Grams) Price (excluding VAT) Availability Qty To Purchase
Atago Digital Portable Salt Meters 4250 Salt concentration (g/100mL) and Temperature ゚C Conductivity Method PAL-SALT 0.00 to 10.0% (g/100mL) 100 £360.00 1 + -
Atago Digital Portable Salt Meters 4251 Salt concentration (g/100mL) and Temperature ゚C Conductivity Method PAL-SALT Mohr 0.00 to 10.0% (g/100mL) 100 £360.00 1 + -
Atago Digital Portable Salt Meters 4225 Fish Salinity % and Temperature ゚C Titration PAL-Fish Fillets Not applicable 100 £580.00 1 + -
Atago Digital Portable Salt Meters 4222 Salt concentration (g/100g) Conductivity Method PAL-SALT PROBE 0.00 to 7.0% 100 £549.33 1 + -
  

Only in the world
Titanium electrode
Longevity and Reliability 

 

PAL-SALT is widely used in various industries for food and industrial solutions. For food products, in addition to checking salt content, salt meter is used to make sure salt is properly added and not forgotten for such product as bread, rice balls and frozen. For industrial use, salt meter is widely used for salt resistance test for cars and such.
*Offset feature use examples
#1. Program a dilution factor to display the original salt%
#2. Program a conversion factor to align the readings with titration methods.
PAL-SALT Mohr gives a reading similar to those obtained from the Mohr’s method (titration). Like other ATAGO salt meters, PAL-SALT Mohr utilizes conductivity to measure samples. This unit also features an offset function which allows for readings to be compensated based on known standards.

Renewal! New release of PAL-Fish Fillets

PAL-FM1 has been renewed and released as a new version, PAL-Fish Fillets - ideal for measuring both dried fish and raw fillets! It is now possible to measure closer to titration values and more precisely with a minimum error of 0.0%*! In addition, by expanding the temperature compensation range to 5 - 40 ゚C, which is more in line with actual environmental site temperatures, measurements have become more stable. Insert the probe into the fillet and in just 3 seconds receive a value that is close to titration. For dried fish, it is recommended to measure in the abdomen area. PAL-Fish Fillets frees the user from the hassle and trouble of past methods!
* According to research. Results depend on the type and position of dried fish and raw fillets being measured.
The PAL-SALT PROBE features convenient operation of submerging the probe in a liquid for measuring the salt content in as fast as 3 seconds. The probe may be inserted directly into semi-solid food. However,measurements at different locations may be inconsistent,and such direct measurements may vary from measurements by dilution methods.
・Electrode pins have extended from 5mm to 10mm for easier measurement.
・Screen now features a backlight for an easier to read

Technical Specifications

Model PAL-SALT PAL-SALT Mohr  PAL-Fish Fillets PAL-SALT PROBE
Cat.No. 4250 4251  4225 4222
Scale Salt concentration (g/100g)
Temperature
Salt concentration (g/100mL)
Temperature
 Fish Salinity %
Temperature ゚C
Salt concentration (g/100g)
Method Conductivity method Conductivity method   Conductivity method
Range 0.00 to 10.0% (g/100g) 0.00 to 10.0% (g/100mL)  0.0 to 10.0%
0.0 to 100 ゚C
0.00 to 7.0%
Resolution 0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
0.01% for salt concentration of 0.00 to 2.99%
0.1% for salt concentration of 3.0 to 10.0%
 0.1%
0.1 C
0.01% (0.00 to 1.99%)
0.1% (2.0 to 7.0%)
Accuracy Displayed value ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision ±5%
(for salt concentration of 1.00 to 10.0%)
Displayed value ±0.05%
(for salt concentration of 0.00 to 0.99%)
Relative precision ±5%
(for salt concentration of 1.00 to 10.0%)
 Fish salinity% :
Absolute Precision ±0.1%(0.0 to 3.9%)
Relative Precision ±5%(4.0 to 10.0%)
* In the case of saline solution
±1゚C
± 0.1% (0.00 to 1.99%)
Relative precision : ± 5% (2.1 to 5.0%)
Relative precision : ± 10% (5.1 to 7.0%)
Dimensions and Weights       Main Unit : 55(W)×31(D)×109(H)mm, 100g
Electrode probe : Φ15×570mm (Cable length : applox.400mm)

 

9 Reasons - Why ATAGO Salt Meters are Chosen

 

Sturdy Titanium Electrodes. Mere 0.08% Failure Rate.

The world’s first to use durable and sturdy “titanium” electrodes. The use of titanium electrodes conquered typical issues like susceptibility to scratches over a period of time and fluctuating measurement results that are common with gold plated electrodes.

Completely Water Protected Model No Other Offers

Rated IP 65 water protection. Ready to sustain tough conditions whether in a kitchen or production floor.

Highly Chemical Resistant PBT Body

 

Highly chemical resistant material, PBT (Polybutylene Terephthalate) is used as a casing material. Unbreakable and sturdy body casing.

 Salinity To A Decimal Point

 

 

We have heard many concerned voices with the accuracy of the conventional salt meters that only display rough estimated salt levels and how results may vary depending on how the sample was measured. ATAGO’s salt meter will not just estimate whether it is too salty or not, but rather numerically display the result as a salt concentration.

Accurate Measurement With Calibration Function

 

The majority of the simplified conventional salt meters do not have calibration function and cannot be calibrated even when measurement values are off. ATAGO’s salt meter can zero set to air and provide calibration service as the JCSS verified manufacturer

High Temperature Soup Can Be Measured Accurately With Drop Style Pal-SALT

 

High temperature and oil containing soup dishes such as miso soup, tsuyu for oden (soup sauce for Japanese one-pot dish consisting of several ingredients such as eggs, konjac and processed fishcakes), ramen soup, can be measured with stable readings. The sample temperature can be anywhere from 5 to 100 ℃ (41 to 212 ˚F) .

Solid Samples Such As Ham, Bacon, Or Himono (Dried Fish) Can Be Measured

 

Solid samples such as ham, bacon, himono, potato chips can be measured by diluting cut or chopped small pieces with water. ATAGO’s salt meter can be used by those with high blood pressure or other lifestyle diseases that would like to record a daily salt consumption measurement.

Perfectly Compact Size With Portability

 

A perfectly compact size to be used on a production floor. Its light weight allows to easily take measurement at home or even when dining out for personal health monitoring.

Renewal! New Release Of Pal-Fish Fillets

 

PAL-FM1 has been renewed and released as a new version, PAL-Fish Fillets - ideal for measuring both dried fish and raw fillets! It is now possible to measure closer to titration values and more precisely with a minimum error of 0.0%*!
In addition, by expanding the temperature compensation range to 5 - 40 ゚C, which is more in line with actual environmental site temperatures, measurements have become more stable. Insert the probe into the fillet and in just 3 seconds receive a value that is close to titration. PAL-Fish Fillets frees the user from the hassle and trouble of past methods!
*According to research. Results depend on the type and position of dried fish and raw fillets being measured.

 

 

Ease of Measurement 

 

Function and Design

 

How To Make Dilution 

 


 

 

Measuring Tips

Thin, drinkable liquids

Thinner or lower concentration liquids, such as soup or miso soup, can be measured by placing a few drops of the sample directly on the sensor.

Thick, syrupy or paste-like liquids

 

Thick, syrupy or paste-like liquids

Sauces, soup bases, seasonings, gravies and such need to be diluted to 10% for accurate measurement results. Anything that is highly concentrated (anything that measures above 6% Brix with a refractometer), must be diluted. The PAL-SALT and ES-421 measure the conductivity of electrolytes through electrical currents (conductivity). The thicker a solution is, the more closely the molecules are packed, and therefore, the less conductive. This makes the sample more difficult to measure. If not diluted, the measurement values may appear lower than the actual salt content.

Products with a salt content that exceeds the measurement range (above 10% salt)


Products with a salt content that exceeds the measurement range (above 10% salt)

Products that contain more than 10% salt, such as pickle brine, need to be diluted. For example, the 10 times dilution of 12% salt brine will measure 1.2%, and the 5 times dilution will measure 2.4%. Adjust the dilution factor so that the salinity falls within the measurement range.

Solid food


Solid food

Solid foods (ham, bacon, dried foods, and fish) need to be minced, ground, or crushed, diluted with water (1:10 dilution), and mixed thoroughly. As a general guideline, let sit for a few minutes (approx. 3 minutes) to allow the salt to leach out of the food. Depending on the qualities of the sample (whether or not the salt is easily drawn out into the water), the salt concentration of the food, the mincing or crushing method, or how well the sample is mixed with the water, the time needed for the salt to be drawn out into the water will vary. Set a soaking period that works for each product (that allows the salt to be thoroughly drawn out). Measure the salinity of the water and multiply the reading by 10. The PAL-SALT PROBE also has a probe sensor that can be inserted directly into the solid sample for measurement.

Oily / fatty food


Oily / fatty food

Foods containing oil or fats can also be measured. However, the measurement values of foods that have oil floating on their surface, such as Ramen soup (a Japanese noodle soup), may be unstable. If the readings fluctuate when measuring oily/fatty foods, try stirring the sample, and measure again for more stable readings. When measuring the salinity of oil-packed products, extract the sample from the oil and allow excess oil to drain. Mix 10g of sample with 90g of water to create a 10% dilution. Mix or shake very well and let settle. Residual oil should float to the top of the container. Take a sample from below the oil layer and place on the sensor. Multiply the displayed reading by 10 to obtain the salt concentration of the original sample.

    • Weight (In Grams)
      100 g
    • SKU
      4250
    • UPC/ISBN
      4560161232420
    • Commodity Codes
      90275000
  • Measurement Range
    Salt Concentration 0.00 to 10.0% (g/100g)
  • Resolution
    0.01%
  • Measurement Accuracy
    ±0.05%
  • Measurement Temperature (°C)
    5 to 100
  • Ambient Temperature (°C)
    10 to 40
  • Use
    Salt Concentration
  • International Protection Class
    IP65
  • Manufacturer
    Atago Co Ltd
  • Country of Origin
    Japan
  • Scale
    Salt concentration (g/100mL) and Temperature ゚C, Fish Salinity % and Temperature ゚C, Salt concentration (g/100g), Brix and Salinity
  • Method
    Conductivity Method, Titration, Not Applicable
  • Model
    PAL-SALT, PAL-SALT Mohr, PAL-Fish Fillets, PAL-SALT PROBE, PAL-BX | SALT +5
  • Range
    0.00 to 7.0%, 0.00 to 10.0% (g/100mL), Not applicable, Brix: 0.0-90.0% and Salinity: 0.00-15.00% (Standard Scale)

The video includes

  • How to use the PAL-SALT
  • How to PREPARE samples like CHEESES and MEATS
  • How to match the values to Titration

Accessories