Anton Paar Portable Alcohol Hydrometer, Alcohol by Volume , for Distilled Spirits

Score: 5.00 (votes: 1)
No reviews.
SKU Model Measuring Range Accuracy Weight (In Grams) Price (excluding VAT) Availability Qty To Purchase
Anton Paar Portable Alcohol Hydrometer, Alcohol by Volume ,  for Distilled Spirits 183054 Snap 41 Alcohol: 0 %v/v to 100 %v/v - Temperature: 5 °C to 30 °C (41 °F to 86 °F) Alcohol: 0.2 %v/v - Temperature: 0.2 °C (0.4 °F) 660 £1797.00 1 + -
Anton Paar Portable Alcohol Hydrometer, Alcohol by Volume ,  for Distilled Spirits 183055 Snap 51 Alcohol: 0 %v/v to 100 %v/v - Temperature: 0 °C to 40 °C (32 °F to 104 °F) Alcohol: 0.1 %v/v - Temperature: 0.1 °C (0.2 °F) 860 £3995.00 1 + -

Snap 41 and Snap 51 are digital alcohol hydrometers for on-site measurement of spirits with outstanding accuracy. One instrument will replace all the glass hydrometers in your distillery and ensure what is on the label is in the bottle. Snap 41/51 measures the alcohol content in all your sugar-free distilled spirits at any strength along the whole production process. Use the portable instrument directly at the container and get results within a few seconds. With cutting-edge technology in a long-life instrument, the Snap series gives your hand-crafted spirits the high-quality measurement they deserve.

Technical Specifications

  Snap 41 Snap 51
Patents granted Patent AT516421 (B1), EP3015847 (B1)
Measuring range Alcohol: 0 %v/v to 100 %v/v
Temperature: 5 °C to 30 °C (41 °F to 86 °F)
(automatic temperature correction)
Alcohol: 0 %v/v to 100 %v/v
Temperature: 0 °C to 40 °C (32 °F to 104 °F)
(automatic temperature correction)
Accuracy Alcohol: 0.2 %v/v
Temperature: 0.2 °C (0.4 °F)
Alcohol: 0.1 %v/v
Temperature: 0.1 °C (0.2 °F)
Repeatability, s.d.* Alcohol: 0.1 %v/v
Temperature: 0.1 °C (0.2 °F)
Alcohol: 0.05 %v/v
Temperature: 0.05 °C (0.1 °F)
Reproducibility, s.d.* Alcohol: 0.15 %v/v Alcohol: 0.07 %v/v
Resolution Alcohol: 0.01 %v/v
Temperature: 0.1 °C (0.1 °F)
Alcohol: 0.01 %v/v
Temperature: 0.01 °C (0.01 °F)
Ambient temperature 0 °C to 35 °C (32 °F to 95 °F) -10 °C to +50 °C (14 °F to 122 °F)
Measuring principle Oscillating U-tube technology Oscillating U-tube technology
Supported measuring units Alcohol concentration in %v/v at 20 °C or at 15 °C, °Proof Alcohol concentration in %v/v (at 20 °C or at 15 °C) or °Proof
Density
Sugar/extract concentration in °Brix or °Plato
Ten programmable custom-specific measuring units
Internal Storage 1024 measured results, 250 sample IDs, 30 measuring methods
Power supply Three 1.5 V LR06 AA alkaline batteries Three 1.5 V LR06 AA alkaline batteries
Sample volume 2 mL 2 mL
Dimensions 245 mm x 103 mm x 126 mm (9.6 in x 4 in x 5 in) 468 mm x 108 mm x 119 mm (18.4 in x 4.3 in x 4.7 in)
Weight 660 g (23.3 ounces) 860 g (30.3 ounces)
Interfaces Bluetooth® (for software update only) Bluetooth® (data transfer to a PC or printer), RFID (sample identification)
Protection class IP54 IP54
Optional available accessories Wristband, rubber protection housing for the operating panel, transportation suitcase Wristband, rubber protection housing for the operating panel, portable Bluetooth® printer, Bluetooth® USB adapter

 

Key Features

Alcohol measurement with easy procedures – no human errors

Alcohol measurement with easy procedures – no human errors

  • No manual temperature correction necessary
  • Get the final result: values are shown in %v/v (corrected to 20 °C and 15 °C for the Japanese market) or °Proof (corrected to 60 °F)
  • Accuracy of 0.2 %v/v
  • Influence of viscosity on your density result is automatically corrected
  • Predefined routine to carry out calibrations with deionized water
  • New adjustment routine ensures alcohol measurements accurate to 0.2 %v/v, even at low measuring temperatures and alcohol concentrations

Only one alcohol meter for distilled spirits at all strengths

Only one alcohol meter for distilled spirits at all strengths

  • Snap 41 replaces all glass hydrometers
  • Measuring range from 0 %v/v to 100 %v/v
  • Usable during all stages of spirits production

Save time and effort with on-site alcohol measurements

Save time and effort with on-site alcohol measurements

  • Sample is taken directly from the storage container with the help of the built-in pump
  • Only 2 mL of sample are required, reducing sample waste to a minimum
  • Measurements can simply be started via a gesture while using your other hand to note down results
  • A measurement is finished within just a few seconds
  • The alcohol content, compensated to the reference temperature, is shown on the color display

An impressively long working life

An impressively long working life

  • Splash-proof housing
  • Special rubber protection for measuring cell included to absorb knocks during routine operation
  • Unique (AT516421 B1) patented design for connection of the measuring cell

Unbeaten usability – for easy-to-learn measuring routines

Unbeaten usability – for easy-to-learn measuring routines

  • Intuitive user interface for an immediate understanding of the instrument
  • Operated via capacitive keys with a sensitivity suitable for use with or without gloves
  • Suitable for both left- and right-handed users
  • Measuring cell with inspection window and backlight for convenient inspection of proper sample filling
  • Automatically rotating screen for conveniently readable results at any instrument position
    • Weight (In Grams)
      660 g
    • SKU
      183054
    • Commodity Codes
      90278080
  • Manufacturer
    Anton Paar GmbH
  • Country of Origin
    Austria
  • Model
    Snap 41, Snap 51
  • Measuring Range
    Alcohol: 0 %v/v to 100 %v/v - Temperature: 5 °C to 30 °C (41 °F to 86 °F), Alcohol: 0 %v/v to 100 %v/v - Temperature: 0 °C to 40 °C (32 °F to 104 °F)
  • Accuracy