Binder 9010-0305 FD115 Standard, 116 Litres, Series FD | Drying and heating chambers Avantgarde.Line with forced convection, FD115-230V, 230 V 1 50/60 Hz

BINDER drying chambers with natural convection or forced convection are renowned for their high quality and reliability. Thanks to their extensive redevelopment, these all-rounders are now even more firmly focused on addressing the requirements involved in drying or heating samples. What's more, in addition to the best energy efficiency on the market and convenient operation, the latest APT.line™ technology offers outstanding temperature accuracy to give this new generation of incubators real appeal.

Important characteristics

  • Temperature range: ambient temperature plus 10 °C to 300 °C
  • Up to 30% lower energy consumption compared to conventional units on the market
  • High temperature accuracy thanks to APT.line™ technology
  • Forced convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Stackable
  • Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm
  • Ergonomic handle design
  • USB port for recording data
Call 01463 830401 For Any Assistance


DesignationFD115-230V¹FD115UL-120V¹
Option modelStandardStandard
Order number9010-03059010-0306
Measures
Interior volume [L]116116
Net weight of the unit (empty) [kg]5050
permitted load [kg]150150
Load per rack [kg]3030
Doors
Unit doors11
Internal Dimensions
Width [mm]550550
Height [mm]550550
Depth [mm]385385
Outer dimensions
Width net [mm]710710
Height net [mm]735735
Depth net [mm]605605
Wall clearance back [mm]160160
Wall clearance sidewise [mm]100100
Environment-specific data
Energy consumption at 150 °C [Wh/h]340340
Sound-pressure level [dB(A)]4343
Fixtures
Number of shelves (std./max.)2/52/5
Performance Data Temperature
Temperature range 10 °C above ambient temperature to [°C]300300
Temperature variation at 150 °C [± K]1.71.7
Temperature fluctuation at 150 °C [± K]0.30.3
Heating-up time to 150 °C [min]1818
Recovery time after 30 seconds door open at 150 °C [min]44
Electrical data
Rated Voltage [V]230120
Power frequency [Hz]50/6060
Nominal power [kW]1.31.4
Unit fuse [A]6.312.5
Phase (Nominal voltage) [ph]11
  1. All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 °C ±3 °C and a power supply voltage fluctuation of ±10 %. The temperature data is determined to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time.
    • SKU
      9010-0305
    • Commodity Codes
      90278080
  • Manufacturer
    BINDER GmbH


DesignationDescriptionArt. No.

Access port with silicone plug
top
100 mm
8012-1671
top
50 mm
8012-1380
top
30 mm
8012-1364
left
10 mm
8012-1276
right
10 mm
8012-1269
top
10 mm
8012-1263
left
50 mm
8012-1020
right
50 mm
8012-1019
left
30 mm
8012-1016
right
30 mm
8012-1015
right
100 mm
8012-1028
left
100 mm
8012-1027
Analog output 4-20 mA
for temperature values (output not adjustable)
8012-1624
Calibration certificate, expanded
for temperature; for extending the measurement in center of chamber to include another test temperature
8012-1116
Calibration certificate, temperature
temperature measurement incl. certificate and 27 measuring points at specified temperature
8012-1594
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature
8012-1573
temperature measurement incl. certificate, 9 measuring points at specified temperature
8012-1552
for temperature, measurement in center of chamber at specified temperature
8012-1135
Cart
Cart – stable cart, casters with locking brakes, dimensions: W 1,000 x D 800 x H 780 mm
9051-0018
Class 3.1 independent temperature safety device
with visual alarm (DIN 12880)
8012-1643
Clock
battery-backed
8012-1641
Data Logger Kit
T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit
8012-0714
Data Logger Software
LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable)
8012-0821
Door gasket
made of FKM, silicone-free
8012-1650
Door lock
lockable door handle
8012-1665
Ethernet interface
for communication software
8012-0988
Gas-tight option model
Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option
8012-1685
Heating output, reinforced
For faster heating up time and improved recovery time; max. 300 °C; not in conjunction with load management option
230 V option model
8012-1057
HEPA air filter
On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm)
8012-1051
Inert gas connection
With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option
8012-1691
Inner chamber, reinforced
max. total load 170 kg
8012-1054
Instrument tray
with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm
large
4022-0124
with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm
small
4022-0123
Interior lighting
with 15 W light bulb
120 V option model
8012-1632
with 15 W light bulb
230/240 V option model
8012-1628
Measurement of air exchange rate
in accordance with ASTM D5374, definition and protocol according to ambient temperature
8012-1195
Overheating alarm
audible, can be switched off, adjustable limit on the independent temperature safety device
8012-1636
pH-neutral detergent
concentrated, for gentle remove of residual contaminants; 1 kg
1002-0016
Pt 100 temperature sensor
additional flexible Pt 100, interior, for displaying the temperature on the unit display
8012-1620
Rack, heavy load
Stainless steel, max. load per rack 70 kg
6004-0199
Racks
chrome-plated
6004-0167
stainless steel
6004-0151
Rubber pads
set of 4 anti-slip feet, for safe stacking of unit
8012-0001
Shelf, perforated
stainless steel
Stainless steel
6004-0183
Software
APT-COM™ communications software
version 3, BASIC edition
9053-0014
APT-COM™ communications software
version 2 to 3, GLP edition
9053-0016
APT-COM™ communications software
version 3, GLP edition
9053-0015
APT-COM™ communications software
version 3, STANDARD edition
9053-0013
APT-COM™ communications software, price: for free
version 3, GLP DEMO Edition
9053-0008
Viewing window and interior lighting
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior
120 V option model
8012-1706
viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior
230 V option model
8012-1704