Anton Paar DMA 35 Portable Density Meter

Score: 5.00 (votes: 1)
No reviews.
SKU Model Ambient Temperature Intrinsic Safety Weight (In Grams) Price (excluding VAT) Availability Qty To Purchase
Anton Paar DMA 35 Portable Density Meter 172244 DMA 35 Standard -10 °C to +50 °C (14 °F to 122 °F) No 660 £3147.00 1 + -
Anton Paar DMA 35 Portable Density Meter 226130 DMA 35 Ampere -10 °C to +50 °C (14 °F to 122 °F) No 660 £3881.00 1 + -
Anton Paar DMA 35 Portable Density Meter 183056 DMA 35 Ex -10 °C to +40 °C (14 °F to 104 °F) Yes 660 £3683.00 1 + -
Anton Paar DMA 35 Portable Density Meter 183057 DMA 35 Ex Petrol -10 °C to +40 °C (14 °F to 104 °F) Yes 660 £3683.00 1 + -

Take DMA 35 with you at all times and measure the density and concentration of your sample directly on-site. One portable density meter replaces all the glass hydrometers in your workplace and gives you the accuracy expected from a lab instrument. DMA 35 uses only two milliliters of sample and saves you a lot of time as there is no need to transport the sample to the lab. It is built to withstand the knocks and spills of outdoor use. An RFID interface for quick sample identification and a Bluetooth® interface for convenient data handling in the field are integral parts of the instrument.

We’ve been making portable density meters since 1981, and have led the global market in density measurement for more than half a century.

A portable density meter providing accurate results, also under harsh conditions

The splash-proof DMA 35 is made for density and concentration measurement in harsh environments, including outdoor operation, while providing the accuracy expected from a lab instrument. The smart oscillator placement makes sure that gas bubbles move to where they can’t affect your result: outside the measuring cell. 

DMA 35 Standard

DMA 35 Ex DMA 35 Ex Petrol DMA 35 Ampere
  • Quality checks in the field, e. g. on wine and wine must (°Brix, °KMW, Oechsle, Baumé)
  • Checks for wort and apparent extract in beer (°Plato)
  • Fermentation graph for each tank directly on the screen
  • One device replaces all glass hydrometers in the workplace

 

  • For measuring flammable chemicals in hazardous environments
  • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
  • Leak-proof sealed housing to withstand rough conditions
  • Protection class IP54
  • For measuring petroleum samples in hazardous environments
  • The only intrinsically safe portable density meter on the market (Ex marking [Ex] II 2 G Ex ib IIB T4)
  • Fully complies with the ASTM D7777 and IP 559 standards
  • Protection class IP54
  • For measuring the specific gravity of sulfuric acid in lead-acid batteries in one second
  • Ideal for use in lead-acid battery production and the maintenance of uninterruptible power supply systems (UPS)
  • Protection class IP54
  • High chemical resistance for use in harsh environments

 

 

Technical Specifications

Patents granted Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1), CN 105571982 B
Other special functions Viscosity correction for reliable measurements, also on highly viscous samples
Gesture control for easy one-handed measurements
Identification of results outside your specified limits
Measuring range Density: 0 g/cm³ to 3 g/cm³
Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
Accuracy Density: 0.001 g/cm³ **
Temperature: 0.2 °C (0.4 °F)
Repeatability, s.d.*** Density: 0.0005 g/cm³ **
Temperature: 0.1 °C (0.2 °F)
Reproducibility, s.d.*** Density: 0.0007 g/cm³
Digital Resolution Density: 0.0001 g/cm³
Temperature: 0.1 °C (0.1 °F)
Ambient temperature****              Standard Version, Ampere Version: -10 °C to +50 °C (14 °F to 122 °F)
Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)
Supported measuring units
  • Specific gravity
  • Alcohol tables
  • Sugar/extract tables
  • API functions
  • H2SO4 tables
  • Ten programmable custom-specific measuring units
Sample volume 2 mL
Dimensions (L x W x H) 245 mm x 103 mm x 126 mm
Data memory 1024 measured results, 30 measuring methods, 250 sample IDs
Power supply Three 1.5 V LR06 AA alkaline batteries
Weight 660 g
Interfaces Bluetooth®, RFID (both included by default)
Protection class IP54 
(first digit: 5 – protection against dust ingress; second digit: 4 – protection against splash water from any direction)
Intrinsic safety of Ex and Ex Petrol version ATEX: II 2G Ex ib IIB T4 Gb
IECEx: Ex ib IIB T4 Gb
Scope of supply Portable density meter, filling tube, adapter for syringe filling, syringes, transportation case, rubber protection for measuring cell, three batteries, Allen key, instructions
Menu language English, German, Chinese, Japanese, French, Russian, Italian, Portuguese, Turkish, Spanish
Available options             

Elongated filling tube 
Portable thermal printer with Bluetooth® interface 
Bluetooth® USB adapter 
Wristband 
Carrying strap 
ISO calibration

  * Measurements up to 100 °C possible 
** Viscosity <300 mPa•s, density <2 g/cm³ 
*** according to ISO 5725 
**** Sample must not freeze within the measuring cell; Ex and Ex Petrol version: -10 °C to +40 °C (14 °F to 104 °F)

DMA is a registered trademark of Anton Paar (EM 013414867) 

Key Features 

Designed for on-site density measurements

  • Leak-proof sealed housing to withstand harsh conditions in industrial and field applications
  • Additional rubber protection keeps the measuring cell safe
  • Operation via capacitive keys so sensitive they can be used with gloves
  • Suitable for both left- and right-handed users
  • RFID tag readings, measurement start or abort, via gesture control: One hand is free to hold you steady with hard-to-reach samples.
  • For sample temperatures up to 100 °C, quick decision support, e. g. in the beer brewing process (measurement of hot wort)
  • Graphical visualization of the fermentation process for each fermentation tank
  • Smart patented oscillator connection (AT516421 B1, EP3015847 B1) permits replacement in case of cell rupture

 

 

Intrinsically safe – for use in hazardous locations

  • Intrinsically safe models DMA 35 Ex and DMA 35 Ex Petrol (Ex marking [Ex] II 2 G Ex ib IIB T4) for use in hazardous areas
  • The only option available on the market for safe measurements in explosive atmospheres
  • DMA 35 Ex is particularly suitable for measuring flammable chemicals.
  • DMA 35 Ex Petrol provides excellent resistance to petroleum samples and fully complies with the ASTM D7777 and IP 559 standards.

Fastest filling and measurement – for a huge variety of samples

  • Fill all kinds of samples – no matter what the viscosity is – in one second using the built-in manual pump or a syringe.
  • No expensive electrical wearing parts: You can easily do all cleaning and maintenance work yourself.
  • Measuring cell with inspection window and backlight for convenient inspection of proper sample filling
  • The most reliable portable density meter for fermenting beer or wine, due to intelligent oscillator placement (potential bubbles automatically move outside the measuring cell)
  • Lock-position of pump preventing sample carryover
  • Auto-rotating display for perfect visibility of results at any instrument position
  • Influence of viscosity on your density result is automatically corrected: for reliable measurements, also on highly viscous samples

 

Perfect traceability of density and concentration results

  • Storage of up to 250 sample IDs for easy sample identification
  • RFID interface for changing measurement settings quickly by reading RFID tags
  • Storage of up to 1024 measurement results including time stamp and sample ID
  • Wireless data exchange with a PC (csv or txt format) and data export to a printer via Bluetooth® for convenient data handling in the field – no extra software required

 

Leave your glass hydrometer or pycnometer for a digital density meter

  • Measurement directly at the sample container
  • Requires only 2 mL of sample, filled via the built-in pump
  • Preinstalled and programmable concentration units – no further calculations necessary
  • Results available in seconds
  • Perfect traceability of results

 

Quickly determining the state of charge of lead-acid batteries

  • Determination of the specific gravity of sulfuric acid
  • Used for measurement of sulfuric acid in lead-acid battery production and maintenance of uninterruptible power supply (UPS) systems
  • Protection class IP54 and high chemical resistance

 

    • Weight (In Grams)
      660 g
    • SKU
      172244
    • Commodity Codes
      90278080
  • Manufacturer
    Anton Paar GmbH
  • Country of Origin
    Austria
  • Model
    DMA 35 Standard, DMA 35 Ex, DMA 35 Ex Petrol, DMA 35 Ampere
  • Measuring Range
    Density: 0 g/cm³ to 3 g/cm³ - Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
  • Accuracy
    Density: 0.001 g/cm³ ** - Temperature: 0.2 °C (0.4 °F)
  • Ambient Temperature
    -10 °C to +50 °C (14 °F to 122 °F), -10 °C to +40 °C (14 °F to 104 °F)