Jenway 570 Portable pH Meter, - 2 to 16 pH range, supplied in a carry case with epoxy pH electrode ( 924 001), ATC probe ( 170 100), buffer sachets and batteries

Technical Specification

 

Model 570
Type pH, mV and temperature
Waterproof Yes (IP66/ 67)
pH Range - 2 to 16
pH Resolution 0.01
pH Accuracy ± 0.02
mV Range - 1000 to 1000mV
mV Resolution 1mV
mV Accuracy ± 1mV
ATC 0 to 100°C
Temperature Range - 39.9 to 149.9°C
Temperature Resolution 0.1°C
Temperature Accuracy ± 0.4°C ( - 10 to 70°C)
No.of Calibration Points 2
Automatic Buffer Recognition Yes
Auto Shut Off 10 mins
Operating Temperature 0 to 100°C
Battery Life (hours) 2500
pH Connector BNC
Temperature Connector Waterproof Lumberg screw-locking type
Dimensions (l x w x d) 141 x 71 x 32mm
Weight 230g
  • £255.15
Qty:  

Model 570 is a general purpose hand held pH, mV and temperature meter. This model offers 2 point calibration and automatic buffer recognition. The unit simultaneously displays either temperature compensated pH readings or electrode potential and temperature. This model has a large easy to read LCD display. The integrated rubber seal ensures that the unit is completely waterproof.

• Simultaneously displays pH or mV and temperature
• Automatic calibration
• Manual or Automatic Temperature Compensation (ATC)
• Auto shut off 10 minutes
• 2500 hours battery life
• Waterproof housing
• 2 year warranty

This meter is supplied ready to use with an epoxy bodied electrode (924 001), a temperature probe (170 100) and buffers and is supplied in a bespoke carry case.

    • SKU
      570271
  • Type
    Portable
  • Manufacturer
    Jenway (part of Cole Parmer)
pplication 924 001 027 227 924 067 924 002 924 005 924 003 924 007 924 010 924 015 924 030 924 034 924 047 924 070 924 049 924 050 924 052 924 051 924 076 924 077 924 078 924 079 924 080
Agar - - - - - - - - - - - + + - - - - -
Alkalines (high) - - - - - - - - - - - - + + - - + + + +
Beer + + - + + + + - + + - - + + + + + + + + + + + + + + + + + +
Blood products + - + + + + - + + + - + + + + + + + + + + + + + + +
Bread/dough - + + - - + + - - + + - - - + - - - - -
Cement + + + + + + + - + + + - + + + + + + + + +
Cosmetics + + + + + + + + + - + + + + + + + + + + + + + + + + +
Dairy products + + + + + + + + + - + + - + + - + + + + + + + + + +
Drinking water + - + - - + - - + + + + - - + + + +
Education + + + + + + + + + + + + + + + + + + + + + + + + + + + +
Fats/cream - + + - + + + - + + - + + + + + + + +
Field use + + + + + - + - - - + + - + + + + + + + + + -
Fish products + + + + + + + - + + - + + + + + + + + +
High temperature - - - - - - - - - - - - - - - + + + +
Jam/preserves - - - - - - - - - - - - - + + - - +
Lab environmental - - - + - - - - - - + + - - - - - -
Lab flasks - - - - - - - - - + + - - - - + + - -
Low ionic - - + + - - + - - - + + + - + + - + + + + -
Meat/cheese - + - - + + - - + + - - - + + - - - - -
Micro samples - - - + + + - + + - + - + - - - - -
Paint - - - + + - + + - - - + + - + + - - - - + +
Photographic - - - - - - - - - - - - + + - - - + +
Soil + + + + + + + + - + + - + + - + + + + +
Surface - - - - - - - - - - - + + - - - - -
Test tubes - - - + - - + + - - + + - - - - - + -
Tris buffer - - - - - - + + - - - + + - + + - - - +
Viscous samples - + - - + - - + - - - + + - + - - -

Key:
++ Electrode recommended for this sample type
+ Electrode would be satisfactory for use with this sample type
– Electrode is not suitable for this application


Combination pH Electrodes

Part Code Description
924 001 General purpose, epoxy bodied for standard measurements of general solutions (max. temperature 60°C)
924 067 Replacement pH electrode with S7 connector (430, max. temperature 60°C)
924 002 12mm stem spear type, glass bodied for measurement of soil and slurry samples
924 003 Redox (platinum), glass bodied for redox measurements
924 005 General purpose, glass bodied for standard measurements of general solutions
924 007 4.5mm semi-micro, 90mm reach, glass bodied for small volume liquid samples
924 010 Spear type, 6mm stem, glass bodied for small volume soil and slurry samples
924 078 350mm reach probe, glass bodied for measurement in flasks
924 015 Glass electrode, pH only requires separate reference electrode
924 070 3 in 1 combination pH temperature, epoxy bodied (370, 3505, 3510, 3520 and 3540 max. temperature 100°C)


Application Specific pH Electrodes

Part Code Description
924 049 Life science, 6mm micro, 150mm reach, glass bodied for test tubes and small sample volumes (max. temperature 100°C)
924 030 Tris buffer, semi-micro with 90mm reach, glass bodied for pH measurements in biological buffers, blood and protein samples (max. temperature 50°C)
924 050 Environmental, glass bodied, suitable for low ionic strength solutions and purified water (max. temperature 50°C)
924 068 Environmental pH electrode with S7 connector (430, max. temperature 50°C)
924 051 Food, epoxy bodied, flat membrane, ideal for measurements of food extracts and agar plates (max. temperature 60°C)
924 069 Food pH electrode with S7 connector (430, max. temperature 60°C)
924 077 Jam electrode, epoxy bodied, ideal for measurements of jam and preserves
924 034 Spear knife probe, epoxy based for the measurement of solid samples
924 035 Replacement electrode for spear knife probe
924 076 Difficult applications, glass bodied for measurement of oils, biofuels and non-aqueous samples and Tris buffers
924 079 High temperature probe, glass bodied for measurements up to 110°C
924 080 Laboratory electrode, glass bodied for measurement of aggressive chemical solutions


Waterproof pH Electrodes

Part Code Description
027 227 Waterproof, general purpose, epoxy–bodied with ATC (max. temperature 100°C)
924 052 Waterproof environmental with ATC (max. temperature 50°C)
924 053 Waterproof 12mm stem spear type, glass bodied with ATC
924 054 Waterproof redox (platinum), glass bodied for redox measurements with ATC
924 055 Waterproof Tris buffer, glass bodied for pH measurements in biological buffers, blood and protein samples with ATC (max. temperature 50°C)
924 056 Waterproof food pH electrode with ATC (max. temperature 60°C)
538 014 Adapter lead with waterproof connector to BNC electrode connector


Temperature and Reference Electrodes

Part Code Description
027 500 ATC/ temperature probe (370, 3505, 3510, 3520 and 3540)
027 502 PTFE-coated ATC probe for use with aggressive/corrosive samples (370, 3505, 3510, 3520 and 3540)
924 016 Single junction, calomel, glass bodied reference electrode (max. temperature 50ºC)
924 017 Double junction, AgCl, glass bodied reference electrode (max. temperature 50ºC)
924 036 Single junction, AgCl, glass bodied reference electrode (max. temperature 100ºC)

Jenway offer a range of pH buffers either as single use sachets or longer lasting 500ml bottles. To care for your Jenway pH electrodes there is also a range of storage solutions and fill solutions tailored to your specific probe.


Ordering Information

Part Code Description
025 037 pH 4 buffer (red, 500ml)
025 038 pH 7 buffer (yellow, 500ml)
025 039 pH 10 buffer (blue, 500ml)
025 162 pH 9.22 buffer (500ml)
025 163 pH 2 buffer (500ml)
025 179 pH 4 buffer sachets (pack of 10)
025 180 pH 7 buffer sachets (pack of 10)
025 181 pH 10 buffer sachets (pack of 10)
025 192 pH electrode storage solution (100ml)
025 196 pH electrode fill solution 4M KCl, AgCl saturated (150ml)
025 197 4M KCl/AgCl partial gel (150ml)
025 160 3M KCl pH fill solution (100ml)
025 161 pH electrode cleaning solution (500ml)
025 157 Redox standard (200mV) (500ml)
025 158 Redox standard (300mV) (500ml)

A number of accessories are available for use with the 550 and 570 pH meters:


Ordering Information

Part Code Description
033274 Carry case for 550 pH meter
033275 Carry case for 570 pH meter
170101 Temperature probe for 550 pH meter
170100 Temperature probe for 570 pH meter