- Acid Corrosive Cabinets
- Arabidopsis Chambers
- Air Compressors
- Anemometer
- Autoclaves
- Balances
- Baths
- Blenders
- BOD Measurement
- Bunsen Burners
- Calibration Weights
- Calorimeters
- Cell Disruptors Ultrasonic
- Cell Manipulation
- Centrifuges
- Chemical Oxygen Demand
- Chromatography Columns & Consumables
- Climate Chambers
- Circulating Coolers
- Cold Boxes
- Colony Counters
- Colorimeters and Photometers
- Conductivity Meters
- Cryogenics
- Density Meters
- Desiccator
- Dissolved Oxygen
- Dispersers
- Dry Block Heaters
- Electrophoresis
- Flocculator
- Freezer Dryers
- Fume Hood Safety Containments
- Furnances
- Glove Box
- Hazardous Storage Cabinets
- Gas Generators
- Heating Mantles & Tapes
- Humidity Cabinets
- Hotplates
- Ice Machines
- Incubators
- Kjeldahl Equipment
- Laboratory Air Drying Cabinet or Warming Cabinet
- Laboratory Glasswashers and Accessories
- Liquid Handling Products
- Melting Point
- Microbiological Safety Cabinets
- Microscopes
- Milling
- Mixers
- Mixing and Storage Vessels
- Multi Parameters Meters
- Organisers and Bins
- Ovens
- PCR Workstation and UV Cabinets
- Plant Growth Cabinets
- Pellet Presses
- Personel Protective Equipment
- pH Measurement
- Pumps
- Refractometers
- Refrigeration - Refrigerators and Freezers
- Rheometers
- Rotators
- Rotary Evaporator
- Shakers
- Sieve Shakers
- Spare Parts
- Specialist Application Products
- Spectrophotometers
- Stirrers
- Stomachers
- Thermal Cyclers
- Toxic Substance Cabinets
- Titration
- Turbidity
- Ultrasonic Cleaners
- Ultra Violet Products
- Vacuum Chambers
- Vibratory Feeder
- Viscometers
- Water Purification Systems
- Water Stills
- Demonstration Stock
IKA Digital Dry Block Heater 1 For 1 Aluminium Block - Adjustable Temperature up to 120 °C
Technical Data
Number of blocks | 1 |
Heat output | 165 W |
Heating temperature range | room temp. +5° - 120 °C |
Temperature display | yes |
Adjustment and display resolution | 1 K |
Connection for ext. temperature sensor | CT (DIN12878) |
PT 1000 variation;DIN EN 60751 Kl. A | ≤ ± (0,15 +0,002xITI) K |
Temperature stability within the blocks at 37°C * | 0.2 ±°C |
Temperature stability within the blocks at 60°C * | 0.4 ±°C |
Temperature Uniformity @ 37°C * | 0.2 K |
Temperature Uniformity @ 60°C * | 0.4 K |
Heatingrate / Heat up time with external sensor * | 5 K/min |
Set-up plate material | Aluminium alloy |
Set-up plate dimensions | 96 x 76 mm |
Fixed safety circuit | 150 °C |
Timer | yes |
Time setting range | 1 - 5999 min |
* Measured in IKA DBH Testingblock | Refer Manual for more details |
Dimensions (W x H x D) | 151 x 73 x 228 mm |
Weight | 1 kg |
Permissible ambient temperature | 5 - 40 °C |
Permissible relative humidity | 80 % |
Protection class according to DIN EN 60529 | IP 21 |
USB interface | no |
RS 232 interface | no |
Voltage | 220 - 240 / 115 / 100 V |
Frequency | 50/60 Hz |
Power input | 165 W |
Includes the following:

A digital block heater for one aluminum block provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates, and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations, and in situ hybridizations.
- Stepless adjustable temperature up to 120 °C
- Timer: Countdown, adjustable from 1 min to 99h 59min
- Counter: Display of heating time
- Highly versatile with a large number of blocks
- Error code display
- Fixed safety circuit
- Acoustic signal at end of the test
Scope of delivery
- Dry Block Heater 1
- Block remove tool
- PT 1000.60 Temperature sensor, stainless steel