- Acid Corrosive Cabinets
- Arabidopsis Chambers
- Air Compressors
- Anemometer
- Autoclaves
- Balances
- Baths
- Blenders
- BOD Measurement
- Bunsen Burners
- Calibration Weights
- Calorimeters
- Cell Disruptors Ultrasonic
- Cell Manipulation
- Centrifuges
- Chemical Oxygen Demand
- Chromatography Columns & Consumables
- Climate Chambers
- Circulating Coolers
- Cold Boxes
- Colony Counters
- Colorimeters and Photometers
- Conductivity Meters
- Cryogenics
- Density Meters
- Desiccator
- Dissolved Oxygen
- Dispersers
- Dry Block Heaters
- Electrophoresis
- Flocculator
- Freezer Dryers
- Fume Hood Safety Containments
- Furnances
- Glove Box
- Hazardous Storage Cabinets
- Gas Generators
- Heating Mantles & Tapes
- Humidity Cabinets
- Hotplates
- Ice Machines
- Incubators
- Kjeldahl Equipment
- Laboratory Air Drying Cabinet or Warming Cabinet
- Laboratory Glasswashers and Accessories
- Liquid Handling Products
- Melting Point
- Microbiological Safety Cabinets
- Microscopes
- Milling
- Mixers
- Mixing and Storage Vessels
- Multi Parameters Meters
- Organisers and Bins
- Ovens
- PCR Workstation and UV Cabinets
- Plant Growth Cabinets
- Pellet Presses
- Personel Protective Equipment
- pH Measurement
- Pumps
- Refractometers
- Refrigeration - Refrigerators and Freezers
- Rheometers
- Rotators
- Rotary Evaporator
- Shakers
- Sieve Shakers
- Spare Parts
- Specialist Application Products
- Spectrophotometers
- Stirrers
- Stomachers
- Thermal Cyclers
- Toxic Substance Cabinets
- Titration
- Turbidity
- Ultrasonic Cleaners
- Ultra Violet Products
- Vacuum Chambers
- Vibratory Feeder
- Viscometers
- Water Purification Systems
- Water Stills
- Demonstration Stock
Electrothermal MC5 Analogue 1-Way Heating Controller , 230V, 50 60 Hz, 800W
Technical Specifications
1-Way Heating Controller model | MC5 | MC242 | MC227 | MC228X1 |
---|---|---|---|---|
Electrical requirements: 230V | 230V, 50 60 Hz, 800W | 230V, 50 60 Hz, 1800W | 230V, 50 60 Hz, 2300W | Not applicable |
Electrical requirements: 115V | 115V, 50 60 Hz, 460W | 115V, 50 60Hz, 1150W | Not applicable | 115V, 50 60Hz, 1100W |
Controller power consumption | 1W | 1W | 1W | 1W |
Dimensions (d x w x h), mm | 130 x 95 x 105 | 130 x 95 x 105 | 115 x 120 x 80 | 115 x 120 x 80 |
Weight, kg | 0.42 | 0.42 | 0.82 | 0.82 |

Analogue Heating Controllers
MC5, MC242, MC227, MC228X1
Electrothermal offer 3 different models of 1-Way Heating Controllers which operate up to 800W (MC5), 1800W (MC242) or 2300W (MC227); MC228X1 is the 115V version of MC227 and operates up to a maximum of 1100W. These heating controllers can control one piece of laboratory equipment at a time, or an equivalent load, i.e. for a CMUV22/L which has 3 elements, an MC5 would be needed on each element.
Electrothermal offer 3 different models of 1-Way Heating Controllers which operate up to 800W (MC5), 1800W (MC242) or 2300W (MC227); MC228X1 is the 115V version of MC227 and operates up to a maximum of 1100W. These heating controllers can control one piece of laboratory equipment at a time, or an equivalent load, i.e. for a CMUV22/L which has 3 elements, an MC5 would be needed on each element.
For all 1-Way Heating Controllers
The MC5, MC242, MC227 and MC228X1 Heating Controllers have been designed to control the heating of resistive loads for bench top operation. The heating controllers deliver different levels of power according to your requirements and are suitable for EM series Electromantles, the Electric Bunsen and Heating Cords and Tapes.
Each heating controller has 2 neon indicators: "Power On" white neon light and "Mantle/Bunsen Heater On" amber neon light. They all have a regulator control knob which can be turned clockwise to increase power. As the knob is turned, the heating controller's amber neon light will pulsate to show that power is being supplied to the equipment being controlled, e.g. mantles, heating tape or cord. The pulse frequency will decrease as the regulator control knob setting is increased, and at maximum setting, the amber neon will be continually illuminated.
A rod support clamp is provided at the rear of each heating controller to take a standard 12.5mm (1/2") diameter rod. They have a short mains lead with an IEC socket to connect them to the resistive load. An accessory extension mains lead is available where remote operation is required, e.g. in a fume extraction unit. The heating controllers can be mounted on standard 1/2" (12mm) dia scaffold or retort stand, they can also be wall mounted using a mounting bracket or stand directly on the bench.
The MC5, MC242, MC227 and MC228X1 Heating Controllers have been designed to control the heating of resistive loads for bench top operation. The heating controllers deliver different levels of power according to your requirements and are suitable for EM series Electromantles, the Electric Bunsen and Heating Cords and Tapes.
Each heating controller has 2 neon indicators: "Power On" white neon light and "Mantle/Bunsen Heater On" amber neon light. They all have a regulator control knob which can be turned clockwise to increase power. As the knob is turned, the heating controller's amber neon light will pulsate to show that power is being supplied to the equipment being controlled, e.g. mantles, heating tape or cord. The pulse frequency will decrease as the regulator control knob setting is increased, and at maximum setting, the amber neon will be continually illuminated.
A rod support clamp is provided at the rear of each heating controller to take a standard 12.5mm (1/2") diameter rod. They have a short mains lead with an IEC socket to connect them to the resistive load. An accessory extension mains lead is available where remote operation is required, e.g. in a fume extraction unit. The heating controllers can be mounted on standard 1/2" (12mm) dia scaffold or retort stand, they can also be wall mounted using a mounting bracket or stand directly on the bench.