Daicel 17G94 CHIRALCEL OJ-10 SFC Supercritical Fluid Chromatography Coated Polysaccharide Derivative Analytical HPLC Column, 150mm, 2.1mm, 10µm

Not rated yet
Free Mainland UK Shipping

1535979632228.png

The surface of the silica gel is coated with cellulose-tris(4-methylbenzoate)

USP L80 specified packing

CHIRALCEL ® OJ-3/SFC and CHIRALCEL ® OJ-H/SFC are positive-phase coated chiral columns for polysaccharide derivatives. The surface of the silica gel is coated with cellulose-tris(4-methylbenzoate).

OJ is currently the most widely used chiral filler in the world. The excellent separation ability and tolerance of OJ column have been reported in various literatures.

CHIRALCEL ® OJ-3/SFC / CHIRALCEL ® OJ-H/SFC is suitable for use in normal phase mobile phases and has the high pressure resistance necessary for use on SFCs.

Solvents that can be used are, for example:

Main mobile phase: CO 2

Auxiliary solvents: MeOH, EtOH, IPA, ACN (no more than 30%)

  • £1615.00
In Stock:  
Filler particle size

CHIRALCEL ® OJ-3/SFC: 3μm

CHIRALCEL ® OJ-H/SFC: 5μm

pressure

8-20Mpa

temperature~25°C
Storage solvent

2-Propanol 100%

※ When the chiral column is used on SFC and used on HPLC, the system is quite different. Please strictly follow the instructions in this manual to avoid irreversible damage.


Column Care

  • The use of a guard column is highly recommended for maximum column life. 
  • Samples should be dissolved in the mobile phase and should be filtered through a membrane filter of approximately 0.5µm porosity.  For alkane containing mobile phases, flush the column with Storage Solvent (Hexane / 2-propanol 9:1) when stored for more than one week. 
  • For columns dedicated to polar solvents, flush the column with the regular mobile phase without the additive. 
  • When washing is required, flush pure Ethanol for 3 hours. (Columns used with alkane/alcohol mobile phase only). 
  • Before flushing with 100% Ethanol use 100% 2-propanol as a transition mobile phase. 


Important Notice

  • STRONGLY BASIC solvent modifiers or sample solutions MUST BE AVOIDED, because they are likely to damage the silica gel used in this column. 
  • Operating this column in accordance with the guidelines outlined here will result in a long column life 
    • SKU
      17G94
    • Commodity Codes
      90279050
  • Manufacturer
    Chiral Technnologies (Part of Daicel Group)
  • Country of Origin
    Japan
  • Chromatography HPLC or GC
    • Particle size (µm)
      10
    • Internal Diameter (mm)
      2.1
    • Length (mm)
      150
    • Packing Phase
      CHIRALCEL ® OJ-10 SFC