Daicel Polymethacrylate Chiral Stationary Phases

Daicel Polymethacrylate Chiral Stationary Phases

CHIRALPAK® OT(+) and OP(+) columns These were the first CSPs invented by Professor Okamoto of Nagoya University (Japan). The chiral selector is a chiral synthetic methacrylate polymer coated onto a 10µm silica support. The best chromatographic results are obtained using 100% Methanol as mobile phase. The polymer used for the CHIRALPAK® OT(+) column is very delicate and is slowly degraded by alcohols. To avoid this phenomenon, we recommend to run the analyses at low temperatures (0 ~ 5°C).

Items: 14 of 4
Show: 40
  • Daicel 23025 CHIRALPAK®  OT(+)  Polymethacrylate Chiral Analytical HPLC Column, 4.6mm, 250mm, 10µm
    • Free Mainland UK Shipping

    Daicel 23025 CHIRALPAK® OT(+) Polymethacrylate Chiral Analytical HPLC Column, 4.6mm, 250mm, 10µm

    CHIRALPAK ® OP(+), CHIRALPAK ® OT(+)

    The 10 μm silica gel surface was coated with a polymethacrylate chiral polymer.
    The separation effect is best when 100% methanol is used as the mobile phase. The chiral polymers in the
    CHIRALPAK ® OT(+) column are very sensitive and can be slowly degraded by alcohols. To avoid degradation, it is recommended to use the chiral column at a lower temperature (0-5 ° C).

    1569953815357.png

    Silicone surface coating - triphenyl-methyl-methacrylate

    CHIRALPAK ® OT (+) is a polymethacrylate chiral column coated with triphenyl-methyl-methacrylate on the surface of the silica gel. 

    The chiral column was used at 0~5 °C, and the separation effect was the best.

    Price Upon Application Or Discontinued
  • Daicel 23022 CHIRALPAK®  OT(+)  Polymethacrylate Chiral Analytical Guard Column, 4.6mm, 50mm, 10µm
    • Free Mainland UK Shipping

    Daicel 23022 CHIRALPAK® OT(+) Polymethacrylate Chiral Analytical Guard Column, 4.6mm, 50mm, 10µm

    CHIRALPAK ® OP(+), CHIRALPAK ® OT(+)

    The 10 μm silica gel surface was coated with a polymethacrylate chiral polymer.
    The separation effect is best when 100% methanol is used as the mobile phase. The chiral polymers in the
    CHIRALPAK ® OT(+) column are very sensitive and can be slowly degraded by alcohols. To avoid degradation, it is recommended to use the chiral column at a lower temperature (0-5 ° C).

    1569953815357.png

    Silicone surface coating - triphenyl-methyl-methacrylate

    CHIRALPAK ® OT (+) is a polymethacrylate chiral column coated with triphenyl-methyl-methacrylate on the surface of the silica gel. 

    The chiral column was used at 0~5 °C, and the separation effect was the best.

    Price Upon Application Or Discontinued
  • Daicel 22022 CHIRALPAK®  OP(+)  Polymethacrylate Chiral Analytical Guard Column, 4.6mm, 50mm, 10µm
    • Free Mainland UK Shipping

    Daicel 22022 CHIRALPAK® OP(+) Polymethacrylate Chiral Analytical Guard Column, 4.6mm, 50mm, 10µm

    CHIRALPAK ® OP(+), CHIRALPAK ® OT(+)

    The 10 μm silica gel surface was coated with a polymethacrylate chiral polymer.
    The separation effect is best when 100% methanol is used as the mobile phase. The chiral polymers in the
    CHIRALPAK ® OT(+) column are very sensitive and can be slowly degraded by alcohols. To avoid degradation, it is recommended to use the chiral column at a lower temperature (0-5 ° C).


    1569954494677.png

     

    Silicone surface coating - diphenyl-(2-pyridyl)methyl-methacrylate

    CHIRALPAK ® OP (+) is a polymethacrylate chiral column coated with diphenyl-(2-pyridyl)methyl-methacrylate on silica gel.

    The separation effect is best when 100% methanol is used as the mobile phase.

    Price Upon Application Or Discontinued
  • Daicel 22025 CHIRALPAK®  OP(+)  Polymethacrylate Chiral Analytical HPLC Column, 4.6mm, 250mm, 10µm
    • Free Mainland UK Shipping

    Daicel 22025 CHIRALPAK® OP(+) Polymethacrylate Chiral Analytical HPLC Column, 4.6mm, 250mm, 10µm

    CHIRALPAK ® OP(+), CHIRALPAK ® OT(+)

    The 10 μm silica gel surface was coated with a polymethacrylate chiral polymer.
    The separation effect is best when 100% methanol is used as the mobile phase. The chiral polymers in the
    CHIRALPAK ® OT(+) column are very sensitive and can be slowly degraded by alcohols. To avoid degradation, it is recommended to use the chiral column at a lower temperature (0-5 ° C).


    1569954494677.png

     

    Silicone surface coating - diphenyl-(2-pyridyl)methyl-methacrylate

    CHIRALPAK ® OP (+) is a polymethacrylate chiral column coated with diphenyl-(2-pyridyl)methyl-methacrylate on silica gel.

    The separation effect is best when 100% methanol is used as the mobile phase.

    Price Upon Application Or Discontinued