Daicel Immobilized Polysaccharide Columns
Daicel immobilized columns exhibit greatly enhanced robustness and remarkable stability. These innovative products allow chromatographers to employ essentially any organic solvent as mobile phase to develop methods for the most challenging separations. These columns are available in a variety of particle sizes and offer superior speed and column resolving power. Columns packed with 3-µm CSPs offer high-speed separations, and a reduction in analysis time and cost per sample. Columns, packed with 3-µm particles, may be used in conventional HPLC units without significant loss in performance, even with the smaller column dimensions.
The immobilized columns are used for applications ranging from analytical method development to large-scale enantiomer resolutions
Subcategories
-
Daicel 80256 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 50mm, 20µm
CHIRALPAK ® IA-3 / CHIRALPAK ® IA
Silica gel surface covalently bonded amylose-tris (3,5-dimethylphenylcarbamate)
IA solvent-resistant chiral column, silica gel surface covalent bond with amylose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 80266 CHIRALPAK ® IA Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 500mm, 100mm, 20µm
CHIRALPAK ® IA-3 / CHIRALPAK ® IA
Silica gel surface covalently bonded amylose-tris (3,5-dimethylphenylcarbamate)
IA solvent-resistant chiral column, silica gel surface covalent bond with amylose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81321 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 50mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81323 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 100mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81324 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 150mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81325 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81394 CHIRALPAK ® IB Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 2.1mm, 150mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81335 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81345 CHIRALPAK ® IB Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 20mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81311 CHIRALPAK ® IB Guard Cartridge (Pack of 3) - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4mm, 10mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81375 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 30mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81355 CHIRALPAK ® IB Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 50mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81337 CHIRALPAK ® IB Guard Semi Preparative HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81423 CHIRALPAK ® IB SFC Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 4.6mm, 100mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81435 CHIRALPAK ® IB SFC Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 10mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81445 CHIRALPAK ® IB SFC Semi Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 20mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81475 CHIRALPAK ® IB SFC Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 30mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81455 CHIRALPAK ® IB SFC Preparative Analytical HPLC Chiral Column - Polysaccharide Derivatives Solvent-Rich Chiral Column, 50mm, 250mm, 5µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81522 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81523 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81525 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 250mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81511 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Chiral Guard Cartridges (Pack of 3), 4mm, 10mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81592 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 50mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81593 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 100mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81594 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 150mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81595 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 250mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81524 CHIRALPAK ® IB-3 Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
IB solvent-resistant chiral column, silica gel surface covalently bonded with cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration.
Solvents that can be used, for example:
Positive phase: n-Hexane, IPA, EtOH
Special mobile phase: Ethyl acetate, CH 3 Cl, THF, MTBE
Reverse phase: H 2 O, IPA, MeOH
-
Daicel 81S82 CHIRALPAK ® IB-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 3mm, 50mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S83 CHIRALPAK ® IB-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 3mm, 100mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S84 CHIRALPAK ® IB-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 3mm, 150mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S22 CHIRALPAK ® IB-3 SFC Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S24 CHIRALPAK ® IB-3 SFC Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S25 CHIRALPAK ® IB-3 SFC Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 250mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S23 CHIRALPAK ® IB-3 SFC Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 100mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S94 CHIRALPAK ® IB-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 150mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 81S95 CHIRALPAK ® IB-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 2.1mm, 250mm, 3µm
Silica gel is covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IB-3 / SFC, CHIRALPAK ® IB / SFC Solvent-based chiral column, silica gel covalently bonded to cellulose-tris (3,5-dimethylphenylcarbamate).
Solvents use unrestricted, wide dissolution conditions, any solvent can be used as a mobile solvent, dissolved samples, chiral column regeneration. And has the necessary anti-high pressure performance when used on SFCs.
Solvents that can be used, for example:
The main mobile phase: CO 2
Solvent: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (not more than 30%)
-
Daicel 80S22 CHIRALPAK ® IA-3 SFC Supercritical Fluid Chromatography Polysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 50mm, 3µm
The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.
Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.
Examples of solvents that can be used:
The main mobile phase: CO 2
Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%
-
Daicel 80S24 CHIRALPAK ® IA-3 SFC Supercritical Fluid Chromatography olysaccharide Derivatives Solvent-Rich Analytical HPLC Chiral Column, 4.6mm, 150mm, 3µm
The surface of silica was covalently bound with amylose - tris (3,5-dimethylphenylcarbamate)
CHIRALPAK ® IA-3 / SFC, CHIRALPAK ® IA / SFC solvent-resistant chiral column with amylose-tris (3,5-dimethylphenylcarbamate) covalently bonded to the surface of silica gel.
Unrestricted use of solvents, a wide range of dissolution conditions, the use of any miscible solvent as a mobile phase, dissolved samples, chiral column regeneration. It also has the necessary high pressure resistance for use on SFC.
Examples of solvents that can be used:
The main mobile phase: CO 2
Auxiliary solvents: Ethyl acetate, CH3Cl, THF, MTBE, n-Hexane, IPA, EtOH, H2O, IPA, MeOH (accounting for no more than 30%