Daicel 14595 CHIRALCEL OD-3 Coated Polysaccharide Derivative Analytical HPLC Column, 250mm, 2.1mm, 3µm

Not rated yet
Free Mainland UK Shipping

The surface of the silica gel is coated with cellulose-tris(3,5-dimethylphenylcarbamate)

USP L40 specified packing

OD is a polysaccharide derivative normal phase coated chiral column, and the surface of the silica gel is coated with cellulose-tris(3,5-dimethylphenylcarbamate).

OD is one of the most widely used chiral fillers in the world. The excellent separation ability and tolerance of OD columns have been reported in various literatures.

CHIRALCEL ® OD-3 / CHIRALCEL ® OD-H / CHIRALCEL ® OD are suitable for use in normal phase mobile phases.

Provide regular analytical columns of different specifications, micro-diameter columns with an inner diameter of 2.1mm, and semi-preparative columns and preparation columns with different inner diameters. You can select the appropriate specifications according to the experimental needs.

  • £1760.00
In Stock:  


Particle sizeCHIRALCEL OD-3: 3 μm
CHIRALCEL OD-H: 5 μm
CHIRALCEL OD: 10 μm
(CHIRALCEL OD preparative column / preparative guard column (50 × 500 mm, 50 × 100 mm): 20 μm)
pressureWe recommend you to use it within the range not exceeding 30 MPa in order to use the column for a long time.
(However, for CHIRALCEL OD, we recommend that you use it within the range not exceeding 10 MPa.)
temperature0 to 40 ° C
Sealing solventn - Hex./IPA=90/10 (v / v)


Column Care

  • The use of a guard column is highly recommended for maximum column life. 
  • Samples should be dissolved in the mobile phase and should be filtered through a membrane filter of approximately 0.5µm porosity.  For alkane containing mobile phases, flush the column with Storage Solvent (Hexane / 2-propanol 9:1) when stored for more than one week. 
  • For columns dedicated to polar solvents, flush the column with the regular mobile phase without the additive. 
  • When washing is required, flush pure Ethanol for 3 hours. (Columns used with alkane/alcohol mobile phase only). 
  • Before flushing with 100% Ethanol use 100% 2-propanol as a transition mobile phase. 


Important Notice

  • STRONGLY BASIC solvent modifiers or sample solutions MUST BE AVOIDED, because they are likely to damage the silica gel used in this column. 
  • Operating this column in accordance with the guidelines outlined here will result in a long column life 
    • SKU
      14595
    • Commodity Codes
      90279050
  • Manufacturer
    Chiral Technnologies (Part of Daicel Group)
  • Country of Origin
    Japan
  • Chromatography HPLC or GC
    • Particle size (µm)
      3
    • Internal Diameter (mm)
      2.1
    • Length (mm)
      250
    • Temperature range (°C)
      0 ~ 40 ℃
    • Packing Phase
      CHIRALCEL ® OD-3