WTW 1P21 CR 3200 Thermoreactors for Chemical Oxygen Demand, 2 x 12 Maximum Number of Samples , Same Program

Not rated yet

Specification

Reactor typeDry temperature control device with safety cover
Cell shafts2 x 12 cell shafts for reaction cells, diameter: 16 ± 0.2 mm
Reaction time settingprogram settings or user-defined programs up to 180 min
Temperature settingstored program, user-defined settings from room temperature up to 170°C
Controlling accuracy± 1 °C ± 1 digit
Temperature stability± 0.5 K
Overtemperature protection190 °C ± 5 °C
DimensionsD x W x H: 312 x 255 x 185 mm
Weight:4 kg
Outputunidirectional RS232 interface with 2 banana sockets for external temperature sensor (article-# 250 100), printer, PC
Power supply115/230 VAC 50/60 Hz switchable via fuse setting
allowed voltage tolerance: ±15 % maximum power consumption: 560 W, Fuse 2x6.3 AT
Protection ClassIP 20 according to EN 60529
Ambient temperatureOperation +5 °C to +40 °C
Climatic class2 according to VDI/VDE 3540
 Relative humidity: Yearly mean: < 75 %
 30 days /year: 95 % Other days: 85 % Light dew: yes
 Site altitude: max. 5000 m above sea level
EMCEN 61326-1
 FCC 47 CFR Part 15
Test certificatescETLus, CE
Safety standardsEN 61010-1
 EN 61010-2-010
 UL 61010-1
 CAN/CSA C22.2#61010-1
 CAN/CSA C22.2#61010-2-010


  • £1111.94
In Stock:  
  • The CR 3200 has 2x12 cuvette slots, all of which can be opened with the same program. The CR 3200 also allows for eight custom programs with free selection of temperature up to 170 °C


Digestions of 24 round cells with pre-programmed and user-defined programs . In total 24 round cells (16 mm) in two seperate heating blocks using the same program

  • 8 stored programs for easy and fast operation including COD fast digestion
  • 8 user-defined programs from room temperature/25-170°C with high temperature digestion
  •  AQA/IQC with optional external temperature sensor for documentation


Programs for standard parameters COD including fast digestion (148°C, 20 min.), total nitrogen, total phosphorus, TOC and heavy metals of galvanizing with automatic heating and switch-off quick. User defined programs can be easily entered and stored from room temperature respectively 25-170°C to perform special digestions and thus allow high temperature digestion.
The very same program can be run for all vials at the same time; to perform two parallel digestion programs, the CR 4200 is the suitable choice. For the analytical quality assurance (AQA), the external temperature sensor TFK CR can be connected to the PC/printer instead of a round cell.

Programs for standard parameters

  • 1: 148 °C for 120 minutes
  • 2: 120 °C for 30 minutes
  • 3: 120 °C for 60 minutes
  • 4: 120 °C for 120 minutes
  • 5: 100 °C for 60 minutes
  • 6: 148 °C for 20 minutes
  • 7: 150 °C for 120 minutes
  • 8: 100 °C for 30 minutes