Binder 9040-0190 CB-S 170 Standard CO₂ Incubators, CB-S Solid.Line, 170 Litre Capacity, CBS170UL-120V

  • Superseded model 9040-0164
Designation

CBS170UL-120V¹

Option model Standard
Order number 9040-0190
Data
Serie CB-S
Performance Data Temperature
Recovery time after 30 seconds door open at 37 °C [min] 8
Temperature fluctuation at 37 °C [± K] 0.1
Temperature range +6 °C above ambient temperature to 50 °C
Temperature variation at 37 °C [± K] 0.3
Performance Data Climate
Humidity range [% RH] 90…95
CO₂-Data
CO₂ measurement IR
CO₂ range [Vol.-% CO₂] 0…20
CO₂ Recovery time after 30 seconds door open at 5 Vol.-% CO₂ [min] 5
Electrical data
Nominal power [kW] 1.3
Phase (Nominal voltage) 1~
Power frequency [Hz] 50/60
Rated Voltage [V] 100…120
Unit fuse [A] 16
Doors
Inner doors 1
Unit doors 1
Housing dimensions not incl. fittings and connections
Depth net [mm] 715
Height net [mm] 870
Width net [mm] 680
Internal Dimensions
Depth [mm] 505
Height [mm] 600
Width [mm] 560
Measures
Interior volume [L] 170
Load per rack [kg] 10
Net weight of the unit (empty) [kg] 90
Permitted load [kg] 30
Wall clearance back [mm] 100
Wall clearance sidewise [mm] 50
Environment-specific data
Energy consumption at 37 °C [Wh/h] 45
Sound-pressure level [dB(A)] 41
Fixtures
Number of shelves (std./max.) 2/6
    • 28% off
    £5500.00, save £1540.00
  • £3960.00
Qty:  

BINDER CO₂ incubators provide optimum growth conditions for a range of cell culture applications. The units guarantee an impressively low risk of contamination, and are quick and easy to clean. Plus, thanks to their low running costs, BINDER CO₂ incubators make for a sound investment. BINDER CB-S series CO₂ incubators feature excellent growth conditions for cell cultures, having been designed for standard applications in the cell laboratory. The proven air jacket system and humidification system keep the incubator interior free from condensation, while the 180 °C hot air sterilization can be relied upon to ensure that bacteria and spores are killed, giving you maximum protection against contamination in the CO₂ incubator. 

CO₂ incubators with hot air sterilization: easy to clean

The incubator design features a seamless inner chamber and rounded corners, making it incredibly easy to clean. The two-part rack frame without screws adds to this, while also ensuring that the incubator is user-friendly. When CB-S series CO₂ incubators are stacked on top of one another, you get an optimum ratio between stand space and usable space, plus 300 liters of incubation capacity, allowing you to carry out your laboratory work comfortably and efficiently.

Incredibly straightforward and efficient to use, CB-S series CO₂ incubators from BINDER provide ideal, reproducible growth conditions for cell cultures. Thanks to the hot air sterilization, spores and bacteria can be killed as necessary, and cells and tissue can be cultivated safely.

Benefits

  • Minimum risk of contamination thanks to +180 °C hot air sterilization
  • Stable pH values thanks to drift-free CO₂ IR sensor technology
  • High humidity up to 95% RH
  • Simple and fast cleaning thanks to a seamless inner chamber


Important characteristics

  • Temperature range: +6 °C above ambient temperature to +50 °C
  • Humidity range: 90 to 95% RH
  • Auto-sterilization with hot air at +180 °C
  • Humidification system with condensation protection
  • CO₂ gas mixing jet with Venturi effect
  • CO₂ sensor with infrared technology
  • LCD to display temperature and CO₂ along with additional information and alarms
  • Internal data logger, measured values can be read out in open format via USB
  • Tightly sealed inner door made of tempered safety glass
  • Seamless stainless steel inner chamber
  • Perforated shelves, stainless steel
  • Units are stackable with stacking adapter
  • Troubleshooting system with visual and acoustic alarms
  • Computer interface: Ethernet
  • Zero-voltage alarm contact
  • Can be stacked with CB model of the same size 

Optional equipment

  • Copper interior fittings consisting of copper shelves and copper-plated water pan
  • Stacking adapter for secure, space-saving installation
  • CO₂ gas tank changer for connecting two gas tanks to one or two incubators
  • CO₂ shaker with corrosion-resistant components in a stainless-steel housing
  • APT-COM Multi Management Software – for managing, recording, and documenting unit parameters
  • Services – wide range of services to ensure that the unit functions correctly



    • SKU
      9040-0190
  • Gross Capacity (L)
    170
  • Dimensions HxWxD (mm)
    870 x 680 x 785
  • Temperature Range (°C)
    6 °C above ambient temperature to +50 °C
  • Construction
    Stainless Steel Interior, Enamelled Steel Exterior
  • CO2 range [Vol.-% CO2]
    0 to 20
  • Humidity range [% RH]
    90 to 95
  • Manufacturer
    BINDER GmbH
Designation Description Art. No.

Access port with silicone plug

left

30 mm
8012-1975

right

30 mm
8012-1976

back

30 mm
8012-1974
Analog output 4-20 mA

for temperature and CO₂ values (outputs not adjustable)

8012-1977
Base

the base equipped with casters is used for the secure positioning and leveling of a BINDER CO₂ incubator

9051-0028
Calibration certificate, expanded

for temperature; for extending the measurement in center of chamber to include another test temperature

8012-1112
Calibration certificate, temperature

for temperature, measurement in center of chamber at specified temperature

8012-1131

temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1549

temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1570

temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1591
Calibration certificate, temperature and CO₂

for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂

8012-0228
Cleaning kit

for equipment maintenance and disinfection, consisting of pH-neutral detergent (1000 g, concentrate), spray disinfectant (500 ml, ready-to-use solution), lint-free cleansing tissues, protective gloves, and protective glasses

8012-0503
Copper interior fittings

Set consisting of 2 shelves (all-copper) and a water pan (copper-plated), more information.

8012-1997
Door hinged on the left

Unit door and standard glass inner door with door hinged on the left

8012-1953
Door lock

lockable door handle

8012-1014
Gas cylinder connection set

for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose

8012-0014
Gas tank changer

external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output

8012-0408
pH-neutral detergent

concentrated, for gentle remove of residual contaminants; 1 kg

1002-0016
Qualification documents

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit

Hard copy inside folder
7007-0001

IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit

Digital in PDF format
7057-0001

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit

Hard copy inside folder
7007-0005

IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit

Digital in PDF format
7057-0005
Rubber pads

set anti-slip feet

8012-0702
Shelf, perforated
Stainless steel
6004-0137
Stacking adapter

for the thermally isolated stacking of two BINDER CO₂ incubators

9051-0035
Stacking frame

stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units

9051-0040


Designation Description Art. No.

CO₂ calibration

CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate

DL30-0401

Execution of IQ/OQ

Execution of IQ/OQ in accordance with qualification folder

DL41-0200

Execution of IQ/OQ/PQ

Execution of IQ/OQ/PQ in accordance with qualification folder

DL44-0500

Maintenance

Functional testing of all electrical and mechanical components, short calibration, documentation in the maintenance schedule

DL20-0400

Temperature calibration

Temperature calibration with 1 measuring point in center of chamber at a specified test temperature, including certificate

DL30-0101

Temperature calibration

Expansion – including certificate, each additional measuring point in center of chamber at specified test temperature

DL30-0102

Temperature measurement, 18 measuring points

Temperature measurement with 18 measuring points at a specified test temperature, including certificate

DL30-0118

Temperature measurement, 27 measuring points

Temperature measurement with 27 measuring points at a specified test temperature, including certificate

DL30-0127

Temperature measurement, 9 measuring points

Temperature measurement with 9 measuring points at a specified test temperature, including certificate

DL30-0109

Unit installation

Unpacking and setting up of unit, connecting to existing connections, and checking function

DL10-0100

Unit instructions

Unit function instructions for operation and programming of the controller

DL10-0500

Warranty extension from 2 to 3 years

The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded

DL02-0041

Warranty extension from 2 to 5 years

The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded

DL02-0042

Recommended Accessories