Binder 9040-0105 CB60 CO₂ Incubators, Series CB , 53 Litres Capacity, with 4x Divided Inner Door, CB060UL-120V-G
The BINDER CB series CO₂ incubator is the premium class among the CO₂ incubators. It is suitable for all sensitive incubation applications and ensures optimal cell growth. A BINDER CB series CO₂ incubator can perform complex cultivation experiments as well as specific environmental conditions.
Benefits
- Maximum usable space with minimal footprint and excellent ease of use
- Minimum risk of contamination thanks to uncompromising hot-air sterilization
- Fanless, easy-to-clean hygienic interior
- Stable pH values thanks to drift-free CO₂ IR sensor technology
- Low evaporation of the medium due to high levels of humidity and quick recovery time
Important characteristics
- Temperature range: from 4 °C above ambient temperature up to 60 °C
- Humidity range: 90 to 95% RH
- CO₂ control range: 0 to 20 vol.% CO₂
- Tried-and-tested anti-contamination concept with 180 °C hot air sterilization
- Optimized double-pan humidification system with condensation protection
- CO₂ gas-mixing jet with Venturi effect
- Hot-air sterilizable CO₂ sensor with single-beam infrared technology
- Intuitive touchscreen controller
- Internal data recording, can be read out in open format via USB interface
- Fail-safe CO₂ automatic diagnosis system for protecting the pH of cell cultures
- DuoDoor™ system: Unit door and glass door can be opened with one handle
- Tightly sealed inner door made of tempered safety glass
- Lockable door handle
- Perforated shelves, stainless steel
- Troubleshooting system with visual and acoustic alarms
- Computer interface: Ethernet
- Zero-voltage alarm contact
- Units are stackable with stacking adapter
Optional equipment
- Versions with O₂ control range: 0.2 to 20 vol.% O₂ or 10 to 95 vol.% O₂
- Versions with humidity control range: 50 to 95% RH due to active humidification
- Convenient water supply with reusable tubular bags,
pre-filled single-litre water bottle, or water container set with magnetic holder, for versions with active humidification - Multi-sectional glass doors with special shelves for dividing up the space to accommodate different experiments
- Stacking adapter for secure, space-saving installation
- CO₂ gas tank changer for connecting two gas tanks to one or two incubators
- CO₂ shaker with corrosion-resistant components in a stainless-steel housing
- APT-COM Multi Management Software – for managing, recording, and documenting unit parameters
- Services – wide range of services to ensure that the unit functions correctly
-
Gross Capacity (L)53
-
Dimensions HxWxD (mm)720 x 580 x 624
-
Temperature Range (°C)7 to 60
-
ConstructionStainless Steel Interior, Enamelled Steel Exterior
-
CO2 range [Vol.-% CO2]0 to 20
-
Humidity range [% RH]90 to 95
-
ManufacturerBINDER GmbH
Designation | Description | Art. No. | ||
---|---|---|---|---|
Access port with silicone plug | ||||
right | 8012-1392 | |||
left | 8012-1391 | |||
back | 8012-1390 | |||
Analog output 4-20 mA | ||||
for temperature and CO₂ values (outputs not adjustable) | 8012-0822 | |||
Base | ||||
with casters | 9051-0031 | |||
Calibration certificate O₂ | ||||
for the O₂ control option; a measuring point in center of chamber at a specified O₂ percentage value | 8012-0229 | |||
Calibration certificate, expanded | ||||
for temperature; for extending the measurement in center of chamber to include another test temperature | 8012-1113 | |||
Calibration certificate, temperature | ||||
temperature measurement incl. certificate and 27 measuring points at specified temperature | 8012-1592 | |||
temperature measurement incl. certificate, 15- 18 measuring points at specified temperature | 8012-1571 | |||
temperature measurement incl. certificate, 9 measuring points at specified temperature | 8012-1550 | |||
for temperature, measurement in center of chamber at specified temperature | 8012-1132 | |||
Calibration certificate, temperature and CO₂ | ||||
for temperature and CO₂, temperature measurement in center of chamber, CO₂ measurement performed using test gas at 37 °C and 5 % CO₂ | 8012-1235 | |||
Electric access port | ||||
8-pin, for low voltage with LEMO socket (coverable) and LEMO plug (max. 24 V – 2 A) | 8012-0826 | |||
Gas cylinder connection set | ||||
for N₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose | 8012-0016 | |||
for O₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose | 8012-0015 | |||
for CO₂, consisting of a gas tank pressure regulator with connection parts and 5-meter hose | 8012-0014 | |||
Gas tank changer | ||||
external, BINDER Gas Supply Service, for connecting 2 gas tanks (CO₂, N₂ or O₂), with audible and visual alarms, as well as zero-voltage alarm output | 8012-0408 | |||
Interface converter | ||||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit | 8012-0557 | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit | 8012-0405 | |||
RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit | 8012-0556 | |||
RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit | 8012-0380 | |||
Interface converter, USB / RS422 | ||||
RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) | 8012-0665 | |||
Interior socket | ||||
waterproof, switched flush-mounting box (LEMO) for nominal voltage in unit interior, coverable, with corresponding plug (nominal voltage; max. 3 A; protection class IP65) | 8012-0823 | |||
O₂ control range | ||||
alternative to the standard range, for controlling O₂ concentrations between 10 and 95 vol. %, only in conjunction with option models with O₂ control | 8012-1106 | |||
pH-neutral detergent | ||||
concentrated, for gentle remove of residual contaminants; 1 kg | 1002-0016 | |||
RS 422 interface | ||||
modular plug distributor for 10 RS 422 interfaces | 8012-0295 | |||
in place of Ethernet, for communication software | 8012-0824 | |||
RS 422 interface, cable (15 m) | ||||
RS 422 connection cable (15 m) between plug distributor and RS 422 interface | 5023-0036 | |||
RS 422 interface, cable (50 m) | ||||
RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor | 5023-0117 | |||
Shelf, perforated | ||||
stainless steel, for divided inner door | 6004-0140 | |||
stainless steel | 6004-0136 | |||
Software | ||||
APT-COM™ communications software | 9053-0016 | |||
APT-COM™ communications software | 9053-0015 | |||
APT-COM™ communications software | 9053-0014 | |||
APT-COM™ communications software | 9053-0013 | |||
APT-COM™ communications software, price: for free | 9053-0008 | |||
Stacking adapter, flat | ||||
for thermally decoupled stacking of two identical units | 9051-0037 |
Designation | Description | Art. No. | ||
---|---|---|---|---|
CO₂ calibration | CO₂ calibration at a specified value, measurements are taken with analyzed test gas at 5%, including certificate | DL30-0401 | ||
Execution of IQ/OQ | Execution of IQ/OQ in accordance with qualification folder | DL41-0200 | ||
Execution of IQ/OQ/PQ | Execution of IQ/OQ/PQ in accordance with qualification folder | DL44-0500 | ||
Maintenance | Functional testing of all electrical and mechanical components, short calibration, documentation in the maintenance schedule | DL20-0400 | ||
O₂ calibration | O₂ calibration with 1 measuring point in center of chamber at a specified O₂ percentage value, including certificate | DL30-0402 | ||
Temperature calibration | Expansion – including certificate, each additional measuring point in center of chamber at specified test temperature | DL30-0102 | ||
Temperature calibration | Temperature calibration with 1 measuring point in center of chamber at a specified test temperature, including certificate | DL30-0101 | ||
Temperature measurement, 18 measuring points | Temperature measurement with 18 measuring points at a specified test temperature, including certificate | DL30-0118 | ||
Temperature measurement, 27 measuring points | Temperature measurement with 27 measuring points at a specified test temperature, including certificate | DL30-0127 | ||
Temperature measurement, 9 measuring points | Temperature measurement with 9 measuring points at a specified test temperature, including certificate | DL30-0109 | ||
Unit installation | Unpacking and setting up of unit, connecting to existing connections, and checking function | DL10-0100 | ||
Unit instructions | Unit function instructions for operation and programming of the controller | DL10-0500 | ||
Warranty extension from 2 to 3 years | The warranty is extended from 2 to 3 years from the delivery date, wear parts are excluded | DL02-1041 | ||
Warranty extension from 2 to 5 years | The warranty is extended from 2 to 5 years from the delivery date, wear parts are excluded | DL02-1042 |