- Acid Corrosive Cabinets
- Arabidopsis Chambers
- Air Compressors
- Anemometer
- Autoclaves
- Balances
- Baths
- Blenders
- BOD Measurement
- Bunsen Burners
- Calibration Weights
- Calorimeters
- Cell Disruptors Ultrasonic
- Cell Manipulation
- Centrifuges
- Chemical Oxygen Demand
- Chromatography Columns & Consumables
- Climate Chambers
- Circulating Coolers
- Cold Boxes
- Colony Counters
- Colorimeters and Photometers
- Conductivity Meters
- Cryogenics
- Density Meters
- Desiccator
- Dissolved Oxygen
- Dispersers
- Dry Block Heaters
- Electrophoresis
- Flocculator
- Freezer Dryers
- Fume Hood Safety Containments
- Furnances
- Glove Box
- Hazardous Storage Cabinets
- Gas Generators
- Heating Mantles & Tapes
- Humidity Cabinets
- Hotplates
- Ice Machines
- Incubators
- Kjeldahl Equipment
- Laboratory Air Drying Cabinet or Warming Cabinet
- Laboratory Glasswashers and Accessories
- Liquid Handling Products
- Melting Point
- Microbiological Safety Cabinets
- Microscopes
- Milling
- Mixers
- Mixing and Storage Vessels
- Multi Parameters Meters
- Organisers and Bins
- Ovens
- PCR Workstation and UV Cabinets
- Plant Growth Cabinets
- Pellet Presses
- Personel Protective Equipment
- pH Measurement
- Pumps
- Refractometers
- Refrigeration - Refrigerators and Freezers
- Rheometers
- Rotators
- Rotary Evaporator
- Shakers
- Sieve Shakers
- Spare Parts
- Specialist Application Products
- Spectrophotometers
- Stirrers
- Stomachers
- Thermal Cyclers
- Toxic Substance Cabinets
- Titration
- Turbidity
- Ultrasonic Cleaners
- Ultra Violet Products
- Vacuum Chambers
- Vibratory Feeder
- Viscometers
- Water Purification Systems
- Water Stills
- Demonstration Stock
Pocket >> Palm >> Perform IoT Supported With NFC Technology
PAL-COFFEE(TDS scale), which famous Baristas are using for their important tools, has the high resolution of 0.01%.The subtle difference in the concentration of coffee and espresso can be measured.Stable readings are possible even with high-temperature, fresh brew due to the continuous measurement feature.
For Brix scale, please choose PAL-Coffee(Brix).
For Double scales of Brix and TDS, pleas choose PAL-Coffee(BX/TDS).
Specifications
Model | PAL-COFFEE (TDS) |
---|---|
Cat.No. | 4532 |
Scale | Total Dissolved Solids (TDS) |
Range | Total Dissolved Solids : 0.00 to 22.00% |
Resolution | Total Dissolved Solids : 0.01% |
Accuracy | ±0.15% |
Temperature compensation | 10 to 100゚C |
Patent for Invention Registration No. ZL200310103015.2 (China)
Patent for Design Registration No. ZL03303431.1 (China), 089244 (Taiwan)
Patent Granted in countries around the world.
We are proud to announce a new addition to the PAL series, PAL-COFFEE.
With the high resolution of 0.01%, the subtle difference in the concentration of coffee and espresso can be measured. Stable readings are possible even with high-temperature, fresh brew due to the continuous measurement feature. Watch the unit take multiple measurements, and read once the measurements stabilize.
PAL-COFFEE(TDS scale), which famous Baristas are using for their important tools, has the high resolution of 0.01%.The subtle difference in the concentration of coffee and espresso can be measured.Stable readings are possible even with high-temperature, fresh brew due to the continuous measurement feature.
PAL commitment
A new ergonomic design for comfort and ease of use! In pursuit of an "easy to use" , "easy to operate" and ergonomic architecture of new instruments, ATAGO has achieved a "palm fitting" masterpiece as well as unit that is high in hygienic properties. By reducing the number of unnecessary assembly parts, we have reduced the risks of a germ reproductive environment. Through our efforts to produce a hygienic instrument to be used in any industry, these units are designed to be completely washable. The new PAL series has been approved by the HACCP, and are equipped with the new ELI feature, which ensures accurate measurements - even outdoors. Requests from our customers worldwide are reflected in the development of the new PAL units
ATAGO Releases NFC (Near Field Communication) Equipped Refractometers
In addition to the Bluetooth enabled refractometers, ATAGO ® released refractometers with near-field communication (NFC) technology for the ease of storing and sharing data with phones, tablets, laptops, and other NFC-equipped devices. Simply by tapping NFC-equipped devices, up to 100 measurement data with the date and time are transferred in a matter of seconds. The NFC solution is simpler and prevents typical human errors in data collection and data generation.
With ever evolving movement of profound change in how human interact with machine automation, this upgrade seizes one’s time to write down measurements with a pen or paper.
How to Use NFC Feature on PAL:
Step 1) For cellphones, download NFC reader app or turn on the NFC feature. For computers, connect the NFC reader.
Step 2) Place NFC reader to the PAL device.
Step 3) Download data.
Quick and easy three steps
![]() |
![]() |
![]() |
Measurement Methods in 3 easy steps
![]() Apply 2-3 drops on the prism surface. |
![]() Press the START key. |
![]() Measurement value and prism temperature are displayed in 3 seconds! |
Features
![]() ![]() |
Light & Compact, 100g. Ergonomically designed for one-handed operation. |
![]() |
Sample size 2-3 drops. |
![]() |
The speedy performance of the PAL is amazing. Simply put a drop of a sample on the prism surface and press the START key. The Brix value ( sugar content / concentration ) will be displayed in just 3 seconds. | ![]() |
High temperature sample can be measured. |
![]() |
Protection class of the PAL is IP65. You can rinse off the sample by running water on the sample stage. The design allows the user to easily wipe off the sample. | ![]() |
Revolutionary new feature ELI* *External Light Interference (ELI) - Patent Pending. |
![]() |
The sample stage is designed to keep sample solutions from spilling out. | ![]() |
Calibration with water only. |
![]() |
The Automatic Temperature Compensation function of the PAL enables you to take measurement readings regardless of the ambient temperature. | ![]() |
Convenient Storage case. |
![]() |
New Digital Hand-Held "Pocket" Meter for PAL-Series Equipped with NFC Data Transmission Function Data history can be accessed by bringing PAL-NFC to any Android devices or PC-linked USB NFC Reader. *The Certification Mark is a trademark or registered trademark of NFC Forum, Inc. in the United States and in other countries. |
-
Measurement RangeTotal Dissolved Solids: 0.00 to 22.00%
-
Resolution0.01%
-
Measurement Accuracy±0.15%
-
Measurement Temperature (°C)10 to 100
-
UseTotal Dissolved Solids
-
International Protection ClassIP65
-
ManufacturerAtago Co Ltd
-
Country of OriginJapan