Atago 2932 Battery Coolant Checker MASTER-BCF, Ethylene Glycol : 32 to -60゚F, Propylene Glycol : 32 to -50゚F Measurement Range

Not rated yet
0


Applications

  • For measuring concentration of antifreeze for automobile radiator at gas station, service station, etc
  • For measuring concentration of antifreeze solution used for central heating system
  • For instantly knowing the freezing temperature of antifreeze solution, etc. in use
  • For measuring specific gravity of battery fluid (dilute sulfuric acid)


Specifications
ModelMASTER-BCF
Cat.No.2932
ScaleFreezing temperature
Battery fluid d20/20
Measurement Range
Ethylene Glycol : 32 to -60゚F
Propylene Glycol : 32 to -50゚F
Minimum Scale
Ethylene Glycol : 10゚F
Propylene Glycol : 10゚F

0.01
Dimensions & Weight3.2 x 3.4 x 16.8cm, 90g
 
Options

· Daylight plate for small volume samplings : RE-2391-50M

* Calibration Certificate : Contact an ATAGO representative for details.

 
Parts

· Daylight plate : RE-2315-61M

 

Design Registration No.000379326-0001, 000379326-0002 (EU)
ZL 2005 3 0116403.4,5 (China), D111526 (Taiwan), D555, 549 (U.S.A.),
1255763, 1255764, 1255765, 1255766, 1255767 (Japan)
Patent Granted in countries around the world.

Call 01463 830401 For Any Assistance
Compact and easy to carryCalibration with water


This refractometer has an exclusive scale for measuring specific gravity of battery fluid and forchecking the freezing temperature of ethylene glycol and propylene glycol which are used as antifreeze mixture in automobiles, thermal catalyst for solar power systems and other industrial applications. MASTER-BCF is the successor model to the conventional BC-3E. The scale is graduated in ゚F. NEW material (which is durable for salty and acid sample) is adopted.

 

 


 
 

This new type of Hand-held Refractometer MASTER functions such as Easy-to-Read, Easy-to-Hold, Smooth sampling, Easy disposal of sample from the edge, the improvement of hygiene aspect by employing the new type of grip, and well balanced structure, emphasis is also placed on its design, well exemplified by the streamlined body and the strong grip with rich texture.

How to choose suitable model?

Step❶

⒈ Please select category, suitable samples or measurement range from the list of MASTER series
⒉ If you are not sure the range of your sample, please refer to our data book


Step❷

Please select the material

⒈ Metal body : Die-cast aluminum, Ideal for the agriculture industry, metal working fluids and various high-temperature samples
⒉ Plastic body : PBT (Polybutylene terephthalate), resistant to salty and acidic samples

Step❸

Please select features
  • α : Water resistant (IP65)
  • T : Automatic temperature compensation (ATC)
  • M : Low cost model without the above function
  • S : Suitable for Milky sample
Protection class of the MASTER-α, H series are IP65. You can rinse off the sample by running water on the prism. The design allows the user to easily wipe off the sample.Sample size 2-3 drops.
The Automatic Temperature Compensation function of the MASTER-α, T, H series enables you to take measurement readings regardless of the ambient temperature.Automatic Sample Distribution (ASD)
New prism housing design allows for sample to cover the prism without having to lift the day-light plate! This design will allow for fast & easy measurements.
Convenient Storage case.  

The MASTER series has been improved with a clearer, brighter field of view and made even easier to carry.

 

Compact Redesign of the MASTER Series (from October 2014)
The MASTER series has been improved with a clearer, brighter field of view and made even easier to carry.
These improvements in our newly compact redesigned models are especially clear when taking measurements in dim lighting, or measuring darkly-colored samples. Even when measuring milky-colored, opaque, or oily samples, the boundary line remains crisp and clear.
Note: The size of the scale has changed. It may take some time to re-adjust to the new field of view when reading measurements.

 

EXPLANATION OF ICONS

Icons, for functions, specifications and scales have been added to this catalog

Function
Can be connected to a recorderCan be connected to a recorderMeasurement at a set temperatureMeasurement at a set temperature
Can be connected to a printerCan be connected to a printerAutomatic Temperature CompensationAutomatic Temperature Compensation
Alarm output for high- and low-limit valuesAlarm output for high- and low-limit valuesCan be connected to a circulating Can be connected to a circulating
RS-232C InterfaceRS-232C InterfaceContinuous measurementContinuous measurement
In-line measurementIn-line measurementHigh temperature samplesHigh temperature samples
User scales can be inputtedUser scales can be inputtedExternal Light InterferenceExternal Light Interference
SpecificationScale
Calibration with waterCalibration with waterClinical refractometersClinical refractometers
Calibration with exclusive standard liquidCalibration with exclusive standard liquidRefractive index scaleRefractive index scale
Compact and easy to carryCompact and easy to carrySalt concentration scaleSalt concentration scale
Digital displayDigital displaySeawater scaleSeawater scale
AC outlet (AC100 to 240V)AC outlet (AC100 to 240V)Wine scaleWine scale
Battery operatedBattery operated  


    • SKU
      2932
    • Commodity Codes
      90275000
  • Measurement Range
    E.G : 0 to 70%, 0 to -50゚C P.G : 0 to 70%, 0 to -50゚C
  • Body Material
    Plastic body : PBT (Polybutylene terephthalate), resistant to salty and acidic samples
  • Other Features
    M : Low cost model - No IP65, No ATC
  • Manufacturer
    Atago Co Ltd
  • Country of Origin
    Japan