Specifications
ModelHHR-2N
Cat.No.2522
ScaleWater Content in Honey
Measurement Range12.0 to 30.0%
(Water Content in Honey)
Minimum Scale0.1%
(Water Content in Honey)
ThermometerTemperature compensation scale
Dimensions & Weight4 x 4 x 17cm, 260g
 
Options

· Standard liquid LK : RE-99010

 
Parts

· Daylight plate with hinge pin : RE-2522-56N

  • £370.00
Qty:  



How to choose suitable model?

Step❶

⒈ Please select category, suitable samples or measurement range from the list of MASTER series

⒉ If you are not sure the range of your sample, please refer to our data book


Step❷

Please select the material

⒈ Metal body : Die-cast aluminium, Ideal for the agriculture industry, metal working fluids and various high-temperature samples
⒉ Plastic body : PBT (Polybutylene terephthalate), resistant to salty and acidic samples

Step❸

Please select features

  • α : Water resistant (IP65)
  • T : Automatic temperature compensation (ATC)
  • M : Low cost model without the above function
  • S : Suitable for Milky sample
Protection class of the MASTER-α, H series are IP65. You can rinse off the sample by running water on the prism. The design allows the user to easily wipe off the sample.Sample size 2-3 drops.
The Automatic Temperature Compensation function of the MASTER-α, T, H series enables you to take measurement readings regardless of the ambient temperature.Automatic Sample Distribution (ASD)
New prism housing design allows for sample to cover the prism without having to lift the day-light plate! This design will allow for fast & easy measurements.
Convenient Storage case.  

The MASTER series has been improved with a clearer, brighter field of view and made even easier to carry.

 

Compact Redesign of the MASTER Series (from October 2014)


The MASTER series has been improved with a clearer, brighter field of view and made even easier to carry.
These improvements in our newly compact redesigned models are especially clear when taking measurements in dim lighting, or measuring darkly-coloured samples. Even when measuring milky-coloured, opaque, or oily samples, the boundary line remains crisp and clear.


Note: The size of the scale has changed. It may take some time to re-adjust to the new field of view when reading measurements.

 

EXPLANATION OF ICONS

Icons, for functions, specifications and scales have been added to this catalogue

Function
Can be connected to a recorderCan be connected to a recorderMeasurement at a set temperatureMeasurement at a set temperature
Can be connected to a printerCan be connected to a printerAutomatic Temperature CompensationAutomatic Temperature Compensation
Alarm output for high- and low-limit valuesAlarm output for high- and low-limit valuesCan be connected to a circulating Can be connected to a circulating
RS-232C InterfaceRS-232C InterfaceContinuous measurementContinuous measurement
In-line measurementIn-line measurementHigh temperature samplesHigh temperature samples
User scales can be inputtedUser scales can be inputtedExternal Light InterferenceExternal Light Interference
SpecificationScale
Calibration with waterCalibration with waterClinical refractometersClinical refractometers
Calibration with exclusive standard liquidCalibration with exclusive standard liquidRefractive index scaleRefractive index scale
Compact and easy to carryCompact and easy to carrySalt concentration scaleSalt concentration scale
Digital displayDigital displaySeawater scaleSeawater scale
AC outlet (AC100 to 240V)AC outlet (AC100 to 240V)Wine scaleWine scale
Battery operatedBattery operated  
    • SKU
      2522
  • Measurement Range
    12.0 to 30.0% (water content in honey)
  • Use
    Water Content in Honey
  • Manufacturer
    Atago Co Ltd

How can I calibrate different ranges of the Refractometers?


Please see below :

[ Hand-Held Refractometers, MASTER Series ]

 Scale AdjustmentTemperature Compensation

MASTER-α series
[ α, Pα, 2α, 3α, 4α, 53α, 10α, 20α, S28α, S10α, S/Millα ]

Not Necessary

Automatic

MASTER-T series
[ 2T, 3T, 4T, 53T ]

Not Necessary as a daily

Automatic

MASTER-M, 10M, 20M, 53M, S28M, S10M, S/MillM

Measure Water at environment temperature, and adjust the scale to Brix 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

MASTER-2M

Adjust the scale with 30% Sucrose Solution
(± 0.03%)

Refer to the temperature compensation table on the instruction manual.

MASTER-3M

Adjust the scale with Standard Liquid LK.
* Please refer to the instruction manual.

MASTER-4M

Adjust the scale with 50% Sucrose Solution
(± 0.05%)

MASTER-H series
[ 50H, 80H, 93H, 100H ]

Not Necessary

Automatic

MASTER-BR

Measure Water at environment temperature, and adjust the scale to 0% • 0°C. (Zero Set)
Please re-do this procedure when the environment temperature changes.

MASTER-RI

Adjust the scale with the Standard Liquid LK. * Please refer to the instruction manual.

N-8α

Measure Water at environment temperature, and adjust the scale to Brix 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

AL-21α

Measure Water at environment temperature, and adjust the scale to Conc 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

HHR-2N

Adjust the scale with the Standard Liquid LK.
* Please refer to the instruction manual.

Read thermometer on the unit.

MJ-1E, RS-32

Measure Water at environment temperature, and adjust the scale to Conc. 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

HSR-500

Measure Water at environment temperature, and adjust the scale to Brix 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

Read thermometer on the unit.

R-5000

Measure Water at environment temperature ( 20°C, and adjust the scale to nD 1.3330. (Zero Set))

[ Hand-Held Refractometers (old products) ]

 Scale AdjustmentTemperature Compensation

ATC-20E

Not Necessary as a daily

Automatic

N-10E, N-20E

Measure Water at environment temperature, and adjust the scale to Brix 0.0%.(Zero Set)
Please re-do this procedure when the environment temperature changes.

S-10E, S-28E

Measure Water at environment temperature, and adjust the scale to Brix 0.0%.(Zero Set)
Please re-do this procedure when the environment temperature changes.

ATC-S/Mill-E

Not Necessary as a daily

Automatic

S/Mill-E

Measure Water at environment temperature, and adjust the scale to Salinity 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

SM-20E, BR-1E

Measure Water at environment temperature, and adjust the scale to Conc. 0.0%. (Zero Set)
Please re-do this procedure when the environment temperature changes.

Recommended Accessories